首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new, simple and sensitive pre-column high-performance chromatographic method for the determination of diabetes marker d-glucose, 1,5-anhydro-d-glucitol and related compounds is reported. Sugars (d-glucose, d-galactose, d-mannose, sucrose and arabinose) were derivatized with benzoic acid (BA) at 80 degrees C for 60 min. l-Fucose, fructose, d-lactose, l-rhamnose, arabinose and ascorbic acid were not reacted. Sugar alcohols (xylitol, erythritol, mannitol, sorbitol myo-inositol) were also derivatized with BA at 80 degrees C for 60 min. The fluorescence derivatives were separated on a TSK amide 80 column (4.6 mm i.d. x 250 mm, 5 microm) with acetonitrile-50 mm acetate buffer (pH 5.6; 4:96, v/v) as the mobile phase. The detection wavelength of beizoic acid derivatives was lambda(ex) 275 nm and lambda(em) 315 nm. The detection limits of sugars were 10-80 microg/mL. The calibration graphs were linear up to 10 mg/mL. The relative standard deviations of 500 microg/mL sugars were 7.0-7.3%. The proposed method was compared with the enzymatic photometric glucose analysis method (Glucose B-Test II Wako). The correlation coefficient was 0.83 (n = 20) and y = 0.82x + 5.91, where y and x are concentrations in microg/mL obtained by the proposed pre-column HPLC and enzyme-photometric method, respectively. The detection limits of sugar alcohols were 100-1000 ng/mL. The calibration graphs were linear to 50 microg/mL and relative standard deviations of 10 microg/mL were 7.2-8.2%. The 1,5-AG data by the proposed method was also compared with the enzymatic photometric 1,5-AG analysis method (Rana AG 1,5-AG determination kit, Nihon Kayaku) and good correlation (r = 0.91, n = 20) was also obtained. The proposed method was applied to the simultaneous determination of d-glucose, 1,5-AG and related sugar alcohols in serum from healthy males.  相似文献   

2.
This paper presents a simple, specific, and precise high-performance liquid chromatographic method for the simultaneous determination of paracetamol (PCM), chlorzoxazone (CXZ), and their related impurities in bulk raw materials and solid dosage forms. The mobile phase consisted of water-methanol-glacial acetic acid (60 + 40 + 2, v/v/v). A column containing octadecylsilane chemically bonded to porous silica particles (Spherisorb ODS 1, 25 cm x 4.6 mm, 5 microm) was used as stationary phase. Detection was performed using a variable wavelength ultraviolet-visible detector set at 272 nm for all compounds. Solutions were injected into the chromatograph under isocratic condition at a constant flow rate of 1.2 mL/min. The method was validated according to International Conference on Harmonization requirements and demonstrates good accuracy and precision and a wide linearity range. The method separates PCM, CXZ, and 3 major impurities [4-aminophenol (4AP), 4'-chloracetanilide (4CA), and p-chlorophenol (PCP)] with fair resolution in less than 15 min. The developed method is rapid and sensitive (limit of detection for 4AP, 4CA, and PCP established at 31.25, 39.06, and 65.16 ng/mL, respectively) and, therefore, suitable for quality control and stability studies of these compounds in dosage forms.  相似文献   

3.
A novel reversed-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the determination of active component triamcinolone acetonide, its degradation product triamcinolone (occurring in formulation after long-term stability tests) and two preservatives presented in the cream-methylparaben and propylparaben, using hydrocortisone as an internal standard.The chromatographic separation was performed on a Supelco Discovery C18 column; the mobile phase for separation of all compounds consists of a mixture of acetonitrile and water (40:60 v/v). The analysis time was less than 9 min, at a flow rate of 0.6 mL min(-1) and detection at 240 nm. The method was found to be applicable for routine analysis (stability tests, homogeneity) in the pharmaceutical product topical cream Triamcinolon cream 0.1%.  相似文献   

4.
ABSTRACT: A simple reversed phase high performance liquid chromatographic method with diode array detector (HPLC-DAD) has been developed and subsequently validated for the determination of fexofenadine hydrochloride (FEX) and its related compounds; keto fexofenadine (Impurity A), meta isomer of fexofenadine (Impurity B), methyl ester of fexofenadine (Impurity C) in addition to the methyl ester of ketofexofenadine (Impurity D). The separation was based on the use of a Hypersil BDS C-18 analytical column (250 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of a mixture of phosphate buffer containing 0.1 gm% of 1-octane sulphonic acid sodium salt monohydrate and 1% (v/v) of triethylamine, pH 2.7 and methanol (60:40, v/v). The separation was carried out at ambient temperature with a flow rate of 1.5 ml/min. Quantitation was achieved with UV detection at 215 nm using lisinopril as internal standard, with linear calibration curves at concentration ranges 0.1-50 μg/ml for FEX and its related compounds. The optimized conditions were used to develop a stability-indicating HPLC-DAD method for the quantitative determination of FEX and its related compounds in tablet dosage forms. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. Complete separation was achieved for the parent compounds and all degradation products. The method was validated according to ICH guidelines in terms of accuracy, precision, robustness, limits of detection and quantitation and other aspects of analytical validation.  相似文献   

5.
El-Kommos ME  Emara KM 《Talanta》1989,36(6):678-679
A reversed-phase high-performance liquid chromatographic method for the determination of six common analgesics (phenyltoloxamine dihydrogen citrate, salicylamide, caffeine, paracetamol, codeine phosphate and phenacetin) is presented. The method is specific for detection and determination of each of these compounds in a complex mixture, without pretreatment. A 10-mum C(18) silica gel stationary phase is used with a methanol-acetonitrile-water-tetrahydrofuran mixture (20:20:55:5 v/v) and spectrophotometric detection at 254 nm. All six components are eluted within 7 min. The method has given good results for three commercial products containing two, three and five active ingredients respectively. Phenacetin, a common analgesic which might be found in other formulations, is used as an internal standard.  相似文献   

6.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of metoprolol and its alpha-hydroxylated metabolite in plasma, Metoprolol, alpha-hydroxymetoprolol and alprenolol (internal standard) are extracted from plasma at alkaline pH with diethyl ether-dichloromethane (4:1, v/v) and back-extracted with 0.01 N sulfuric acid. A 100-microliter volume of the acidic extract is injected into the chromatographic system. The compounds are eluted in about 12 min with acetonitrile-acetate buffer (75:25, v/v) on a LiChrosorb RP-8 (5 micron) column. The quantitative determinations are made fluorometrically. Concentrations down to 35 nmol/1 (10 ng/ml) of metoprolol base and 30 nmol/1 (8 ng/ml) of alpha-hydroxymetoprolol base in plasma can be determined with good precision and accuracy.  相似文献   

7.
A high-performance liquid chromatographic electrochemical detection for the rapid and simultaneous determination of the vitamin A, D3 and E is described. The separation is carried out by using a C18 reversed-phase column and 0.1 M LiClO4 in methanol-water (99:1, v/v) as the mobile phase. The compounds are eluted with good resolution in the above order within about 15 min and are determined by amperometric detection with a glassy carbon electrode at +1050 mV (vs. Ag/AgCl). The method gave reproducible results and the detection limits were of the order of 0.07, 4 and 0.2 ng of vitamin A, D3 and E, respectively. The method was successfully applied to the determination of vitamin A, D3 and E in liquid cow milk and milk powder samples. After saponification, fat-soluble vitamins were extracted with hexane and a methanolic solution of the dried extract was injected directly into the chromatographic system, avoiding the clean-up step that is necessary for vitamin D3 when electrochemical detection is not used. Good recoveries were obtained.  相似文献   

8.
This work presents a fast method for the simultaneous separation and determination of glimepiride, glibenclamide, and two related substances by RP LC. The separation was performed on a Chromolith Performance (RP-18e, 100 mm x 4.6 mm) column. As mobile phase, a mixture of phosphate buffer pH 3, 7.4 mM, and ACN (55:45 v/v) was used. Column oven temperature was set to 30 degrees C. The total chromatographic run time was 80 s. This was achieved using a flow program from 5 to 9.9 mL/min. Precisions of the interday and the intraday assay for both retention times and peak areas for the four analyzed compounds were less than 1.2%. The method showed good linearity and recovery. The short analysis time makes the method very valuable for quality control and stability testing of drugs and their pharmaceutical preparations.  相似文献   

9.
Abstract

A reversed phase high-performance liquid chromatographic method (HPLC) for the simultaneous determination of diazepam and its three active metabolites, nordazepam, oxazepam and temazepam, in plasma was proposed. The compounds were isolated by solid-phase extraction. The chromatographic mobile phase was metanol-water (55:45, v/v) at a flow rate of 1 mL/min. UV detection was performed concurrently at 240 and 254 nm.  相似文献   

10.
A high performance liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) method for simultaneous screening and quantification of 28 drugs was developed and validated for 2.5 mg hair samples. Target drugs and their metabolites included amphetamines, cocaine, opioids, benzodiazepines, antidepressants, and hallucinogens. After decontamination, hair samples were extracted with 200 μL of a mixture of water: acetonitrile:1 M trifluoroacetic acid (80:10:10, v/v) using a 5 min simultaneous pulverization/extraction step. The extracts were analysed by HPLC-HRMS in an Orbitrap at a nominal resolution of 60,000, with concomitant in source collisional experiments (in source CID). Gradient elution on an Atlantis T3 column resolved 28 target compounds and 5 internal standards. Total chromatographic run time was 26 min. Calibration was achieved by linear regression analysis utilizing six calibration points; R2 ranged from 0.9964 to 0.9999, the limits of quantification were 0.1 ng/mg for 8 compounds, 0.2 ng/mg for 16 compounds and 0.5 ng/mg for 4 compounds; mean relative errors from -21% to +23% were obtained; relative standard deviation, used to estimate repeatability and intermediate reproducibility at three concentrations, was always less than 20%. Process efficiency and recoveries for all analytes were better than 65 and 73%, respectively, at any concentration. The method was applied to hair samples from forensic investigations that contained a broad assortment of drugs of abuse and pharmaceuticals. The use of concomitant HRMS full scan and CID afforded the possibility of retrospective analysis for discovering untargeted drugs.  相似文献   

11.
A simple, rapid and reproducible reversed-phase high-performance liquid chromatographic method for the simultaneous determination of benzoic acid (BA), phenylacetic acid (PAA) and their respective glycine conjugates hippuric acid (HA) and phenaceturic acid (PA) in sheep urine is described. The procedure involves only direct injection of a diluted urine sample, thus obviating the need for an extraction step or an internal standard. The compounds were separated on a Nova-Pak C18 column with isocratic elution with acetate buffer (25 mM, pH 4.5)-methanol (95:5). A flow-rate of 1.0 ml/min, a column temperature of 35 degrees C and detection at 230 nm were employed. These conditions were optimized by investigating the effects of pH, molarity, methanol concentration in the mobile phase and column temperature on the resolution of the metabolites. The total analysis time was less than 15 min per sample. At a signal-to-noise ratio of 3 the detection limits for ten-fold diluted urine were 1.0 microgram/ml for BA and HA and 5.0 micrograms/ml for PAA and PA with a 20-microliters injection.  相似文献   

12.
A rapid and selective high-performance liquid chromatographic (HPLC) method is developed for the separation and determination of caffeine, theobromine, and theophylline. The chromatography is performed on a Zorbax Eclipse XDB-C8 column (4.6 x 150 mm i.d., 5-microm particle size) at 25 degrees C, with a mobile phase of water-THF (0.1% THF in water, pH 8)-acetonitrile (90:10, v/v). The flow rate is 0.8 mL/min, and detection is by UV at 273 nm. This method permits the simultaneous determination of caffeine, theobromine, and theophylline in food, drinks, and herbal products with detection limits of 0.07-0.2 mg/L and recoveries of 100.20-100.42%. Correlation coefficients, for the calibration curves in the linear range of 0.2-100 mg/L, are greater than 0.9999 for all compounds. The within- and between-day precision is determined for both retention times and peak area. The data suggests that the proposed HPLC method can be used for routine quality control of food, drinks, and herbal products.  相似文献   

13.
A method for quantifying of ethinylestradiol (ETE) and levo-norgestrel (LEV) in pharmaceutical products by micellar electrokinetic chromatography (MEKC) is described. The separation was carried out at 25 degrees C and 25 kV, using a 20 mM borate buffer (pH 9.2), 15 mM sodium dodecylsulfate (SDS) in 30% acetonitrile/water (v/v). Under these conditions the analysis takes about 7 min. The method has been applied for quantifying both compounds in six different commercial contraceptives and the proposed method gave good results when compared with a reference liquid chromatographic (LC) method.  相似文献   

14.
This contribution describes the use of a new separation method based on a reversed-phase sequential injection chromatography (SIC) technique for simultaneous determination of chloramphenicol and betamethasone in pharmaceutical eye drops. A short monolithic column coupled with a sequential injection analysis (SIA) system enabled separation of two compounds in one step. A Chromolith Flash RP-18e, 25 x 4.6 mm column with a 5 mm precolumn (Merck, Germany) and a FIA1ab 3000 system (USA) with a 6-port selection valve and 5 mL syringe were used for sequential injection chromatographic separations in this study. The mobile phase used was acetonitrile-water (30:80, v/v), flow rate 0.48 mL/min; UV detection was at two wavelengths, i.e., 241 and 278 nm (absorption maxima of betamethasone and chloramphenicol, respectively). The basic validation parameters showed good results: linearity of determination for both compounds including internal standard (propylparaben) >0.999; repeatability of determination (RSD) in the range 0.8-1.7% at two different concentration levels, and detection limits in the range 0.5-1.0 mg/mL. The chromatographic resolution between compound peaks was greater than 2.1 and the analysis time was less than 8 min under optimal conditions. The developed sequential injection chromatography method was compared with the HPLC method and was found to be applicable for routine analysis of active compounds in pharmaceutical preparations.  相似文献   

15.
A selective and sensitive reversed-phase (RP) high-performance liquid chromatographic method is developed for the quantitative analysis of five naturally occurring flavonoids of Blumea balsamifera DC, namely dihydroquercetin-7,4'-dimethyl ether (DQDE), blumeatin (BL), quercetin (QN), 5,7,3',5'-tetrahydroxyflavanone (THFE), and dihydroquercetin-4'-methyl ether (DQME). These compounds have been isolated using various chromatographic methods. The five compounds are completely separated within 35 min using an RP C18, Nucleosil column and with an isocratic methanol-0.5% phosphoric acid (50:50, v/v) mobile phase at the flow rate of 0.9 mL/min. The separation of the compounds is monitored at 285 nm using UV detection. Identifications of specific flavonoids are made by comparing their retention times with those of the standards. Reproducibility of the method is good, with coefficients of variation of 1.48% for DQME, 2.25% for THFE, 2.31% for QN, 2.23% for DQDE, and 1.51% for BL. The average recoveries of pure flavonoids upon addition to lyophilized powder and subsequent extraction are 99.8% for DQME, 99.9% for THFE, 100.0% for BL, 100.6% for DQDE, and 97.4% for QN.  相似文献   

16.
Liu H  Shao J  Li Q  Li Y  Yan HM  He L 《Journal of AOAC International》2012,95(4):1138-1141
A simple, rapid method was developed for simultaneous extraction of trigonelline, nicotinic acid, and caffeine from coffee, and separation by two chromatographic columns in series. The trigonelline, nicotinic acid, and caffeine were extracted with microwave-assisted extraction (MAE). The optimal conditions selected were 3 min, 200 psi, and 120 degrees C. The chromatographic separation was performed with two columns in series, polyaromatic hydrocarbon C18 (250 x 4.6 mm id, 5 microm particle size) and Bondapak NH2 (300 x 3.9 mm id, 5 microm particle size). Isocratic elution was with 0.02 M phosphoric acid-methanol (70 + 30, v/v) mobile phase at a flow rate of 0.8 mL/min. Good recoveries and RSD values were found for all analytes in the matrix. The LOD of the three compounds was 0.02 mg/L, and the LOQ was 0.005% in the matrix. The concentrations of trigonelline, nicotinic acid, and caffeine in instant coffee, roasted coffee, and raw coffee (Yunnan Arabica coffee) were assessed by MAE and hot water extraction; the correlation coefficients between concentrations of the three compounds obtained were close to 1.  相似文献   

17.
A reversed-phase liquid chromatographic (LC) method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical dosage forms. The LC method was carried out on a Synergi fusion C18 column (150 mm x 4.6 mm id) maintained at 45 degrees C. The mobile phase consisted of phosphate buffer 0.03 M, pH 4.5-acetonitrile (35 + 65, v/v) run at a flow rate of 0.6 mL/min, and detection was made using a photodiode array detector at 234 nm. The chromatographic separation was obtained within 15.0 min, and calibration graphs were linear in the concentration range of 0.5-200 microg/mL. Validation parameters such as specificity, linearity, precision, accuracy, and robustness were evaluated, giving results within the acceptable range for both compounds. Moreover, the proposed method was successfully applied for the routine quality control analysis of pharmaceutical products.  相似文献   

18.
A simple and valid thin-layer chromatographic method for the separation and quantitative determination of valienamine and validamine is described. The two compounds are separated using a Silica gel G plate as the stationary phase and a mixture of 1-PrOH-AcOH-H2O (4:1:1, v/v/v) as the mobile phase. The plate is developed for 1 h at 25 degrees C and dried by a hairdrier, then immersed in 0.1% ninhydrin aqueous solution and heated for 5 min at 121 degrees C. The reacted spots are scanned with a single wavelength at 420 nm in the measurement mode of absorption. The limits of detection of the two compounds are both 0.4 microg. The responses of the densitometry are highly correlated with the amounts of valienamine and validamine in the range of 0.4-2.8 pg. Moreover, the method shows good accuracy and high precision.  相似文献   

19.
Gao L  Yu B  Yang H 《色谱》2011,29(11):1112-1117
应用高速逆流色谱法从母丁香和公丁香中快速分离了3种已知非挥发性化合物,并利用相同方法从公丁香中分离出2种色原酮类化合物。两相溶剂系统A为正己烷-乙酸乙酯-甲醇-水(5:8:6:13, v/v/v/v),系统B为正己烷-乙酸乙酯-甲醇-水(5:8:9:10, v/v/v/v),以系统A的上相为固定相,系统A和B的下相为流动相,利用梯度洗脱方式,在主机转速为880 r/min、流速1.2 mL/min条件下,成功地从70 mg母丁香粗提物中分离得到12.3 mg鞣花酸、9.6 mg鼠李素、17.2 mg槲皮素,从50 mg公丁香粗提物中分离得到5,7-二甲氧基-2-甲基色原酮10.2 mg、5,7-二甲氧基-2,6-二甲基色原酮8.6 mg,纯度均在96%以上。各化合物的结构均由质谱和核磁共振氢谱、碳谱鉴定。利用该方法可以对丁香不同药用部位中的非挥发性化合物进行有效的分离和纯化。  相似文献   

20.
A high-performance liquid chromatographic method for the determination of methyl paraoxon in plasma has been developed. Disodium EDTA and aluminon are used to inhibit hydrolysis of methyl paraoxon in plasma. Methyl paraoxon and the internal standard fenitrooxon are extracted from plasma into methylene chloride. Chromatography is performed on a reversed-phase C18 column, connected with a fixed-wavelength ultraviolet detector at 280 nm; the compounds are eluted in about 5 min with tetrahydrofuran-acetonitrile-0.01 M sodium phosphate buffer, pH 7.4 (12:25:63, v/v/v). Concentrations down to 5 ng/ml methyl paraoxon in plasma can be determined with good precision and accuracy. The method was applied to plasma samples from dogs after intravenous administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号