首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
Traditionally, Fourier spectroscopic imaging is associated with a small k-space coverage which leads to truncation artifacts such as "bleeding" and ringing in the resultant image. Because substantial truncation artifacts mainly arise from regions having intense signals, such as the subcutaneous lipid in the head, effective reduction of truncation artifacts can be achieved by obtaining an extended k-space coverage for these regions. In this paper, a hybrid technique which employs phase-encoded spectroscopic imaging (SI) to cover the central portion of the k-space and echo-planar spectroscopic imaging (EPSI) to measure the peripheral portion of the k-space is developed. EPSI, despite its inherently low SNR characteristics, provides a sufficient SNR for outer high-spatial frequency components of the aforementioned high signal regions and supplies an extended k-space coverage of these regions for the reduction of truncation artifacts. The data processing includes steps designed to remove inconsistency between the two types of data and a previously described technique for selectively retaining only outer k-space information for the high signal regions during the reconstruction. Experimental studies, in both phantoms and normal volunteers, demonstrate that the hybrid technique provides significant reduction in truncation artifacts.  相似文献   

2.
The effects of cerebral ischemia in rat brain were monitored as a function of time using proton MR imaging. Spinspin relaxation time (T2), proton density, and magnetization transfer contrast (MTC) were measured by MR imaging at various time intervals during a 1-week period following the induction of ischemic damage. Ischemic injury was characterized by a maximization of both T2 value and MTC appearance at 24 hr postischemic injury. These changes were accompanied by a gradual increase in MR observable water density over the first few days of ischemia. A reduction in the magnetization exchange rate between “free” and “bound” water protons as measured by MTC imaging is at least partially responsible for the elevation in T2 values observed during ischemia, and may accompany breakdown of cellular structure.  相似文献   

3.
Visualization of short echo time (TE) metabolites in prostate magnetic resonance spectroscopic imaging is difficult due to lipid contamination and pulse timing constraints. In this work, we present a modified pulse sequence to permit short echo time (TE=40ms) acquisitions with reduced lipid contamination for the detection of short TE metabolites. The modified pulse sequence employs the conformal voxel MRS (CV-MRS) technique, which automatically optimizes the placement of spatial saturation planes to adapt the excitation volume to the shape of the prostate, thus reducing lipid contamination in prostate magnetic resonance spectroscopic imaging (MRSI). Metabolites were measured and assessed using a modified version of LCModel for analysis of in vivo prostate spectra. We demonstrate the feasibility of acquiring high quality spectra at short TEs, and show the measurement of short TE metabolites, myo-inositol, scyllo-inositol, taurine and glutamine/glutamate for both single and multi-voxel acquisitions. In single voxels experiments, the reduction in TE resulted in 57% improvement in the signal-to-noise ratio (SNR). Additional 3D MRSI experiments comparing short (TE=40 ms), and long (TE=130 ms) TE acquisitions revealed a 35% improvement in the number of adequately fitted metabolite peaks (775 voxels over all subjects). This resulted in a 42 ± 24% relative improvement in the number of voxels with detectable citrate that were well-fitted using LCmodel. In this study, we demonstrate that high quality prostate spectra can be obtained by reducing the TE to 40 ms to detect short T2 metabolites, while maintaining positive signal intensity of the spin-coupled citrate multiplet and managing lipid suppression.  相似文献   

4.
Magnetic resonance spectroscopic imaging (MRSI) is a noninvasive technique for producing spatially localized spectra. MRSI presents the important challenge of reducing the scan time while maintaining the spatial resolution. The preferred approach for this is to use time-varying readout gradients to collect the spatial and chemical-shift information. Fast, three-dimensional (3D) spatial encoded methods also reduce the scan time. Despite the existence of several new and faster 3D encoded methods, or k-space trajectories, for magnetic resonance imaging (MRI), only stack of spirals and echo planar have been studied in 3D MRSI. A novel formulation for designing fast, 3D k-space trajectory applicable to 3D MRSI is presented. This approach is simple and consists of rays expanding from the origin of k-space into a revolving sphere, collecting spectral data of all 3D spatial k-space at different times in the same scan. This article describes this new method and presents some results of its application to 3D MRSI. This technique allows some degree of undersampling; hence, it is possible to reconstruct high-quality undersampled spectroscopic imaging in order to recognize different compounds in short scan times. Additionally, the method is tested in regular 3D MRI. This proposed method can also be used for dynamic undersampled imaging.  相似文献   

5.
Magnetic Resonance Spectroscopic Imaging (MRSI) is a technique for imaging spatial variation of metabolites and has been very useful in characterizing biochemical changes associated with disease as well as response to therapy in malignant pathologies. This work presents a self-calibrated undersampling to accelerate 3D elliptical MRSI and an extrapolation-reconstruction algorithm based on the GRAPPA method. The accelerated MRSI technique was tested in three volunteers and five brain tumor patients. Acceleration allowed larger spatial coverage and consequently, less lipid contamination in spectra, compared to fully sampled acquisition within the same scantime. Metabolite concentrations measured from the accelerated acquisitions were in good agreement with measurements obtained from fully sampled MRSI scans.  相似文献   

6.
On the basis of propositions of the common fluctuation theory, peculiarities of small fluctuations in real physical systems with limited sizes are analyzed. It is established that small fluctuations should necessarily be divided into two types of fluctuations: “small” and “very small”. It is shown that the damping process of “small” fluctuations has relaxation character, while the damping process of “very small” fluctuations is of random character, i.e., it represents a random rectangular signal. The probability density of “very small” fluctuations is shown to be Gaussian. The agreement of the obtained results with experimental data acquired from semiconductor-based devices is analyzed. A relation between the generation–recombination noise and phonon number fluctuations in semiconductors is studied. On the basis of this consideration it is shown that the Schönfeld pulse spectrum preserves its well-known 1/f form only in the range of intermediate frequencies; at lower frequencies the spectrum gets saturated. An expression for the low-frequency limit of Schönfeld pulse 1/f law is obtained.  相似文献   

7.
The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors relative to previous studies that used a 1.5 T scanner and a quadrature head coil. Issues that were of concern included differences in chemical shift artifacts, line broadening due to increased susceptibility at higher field strengths, changes in relaxation times and the increased complexity of the postprocessing software due to the need for combining signals from the multichannel data. Simulated and phantom spectra showed that very selective suppression pulses with a thickness of 40 mm and an overpress factor of at least 1.2 are needed to reduce chemical shift artifact and lipid contamination at higher field strengths. Spectral data from a phantom and those from six volunteers demonstrated that the signal-to-noise ratio (SNR) in the eight-channel coil was more than 50% higher than that in the quadrature head coil. For healthy volunteers and eight patients with brain tumors, the SNR at 3 T with the eight-channel coil was on average 1.5 times higher relative to the eight-channel coil at 1.5 T in voxels from normal-appearing brains. In combination with the effect of a higher field strength, the use of the eight-channel coil was able to provide an increase in the SNR of more than 2.33 times the corresponding acquisition at 1.5 T with a quadrature head coil. This is expected to be critical for clinical applications of MRSI in patients with brain tumors because it can be used to either decrease acquisition time or improve spatial resolution.  相似文献   

8.
“End of Moore’s Law” has recently become a topic. Keeping the signal-to-noise ratio (SNR) at the same level in the future will surely increase the energy density of smaller-sized transistors. Lowering the operating voltage will prevent this, but the SNR would inevitably degrade. Meanwhile, biological systems such as cells and brains possess robustness against noise in their information processing in spite of the strong influence of stochastic thermal noise. Inspired by the information processing of organisms, we propose a stochastic computing model to acquire information from noisy signals. Our model is based on vector matching, in which the similarities between the input vector carrying external noisy signals and the reference vectors prepared in advance as memorized templates are evaluated in a stochastic manner. This model exhibited robustness against the noise strength and its performance was improved by addition of noise with an appropriate strength, which is similar to a phenomenon observed in stochastic resonance. Because the stochastic vector matching we propose here has robustness against noise, it is a candidate for noisy information processing that is driven by stochastically-operating devices with low energy consumption in future. Moreover, the stochastic vector matching may be applied to memory-based information processing like that of the brain.  相似文献   

9.
Methane activation catalyzed over Ag-exchanged ZSM-5 zeolites was investigated by using the density functional theory (DFT) with a cluster model. Two different pathways were taken into account in this work: the “alkyl” and the “carbenium” pathways. The activation barriers obtained are 34.09 and 66.63 kcal/mol for the “alkyl” and the “carbenium” pathway, respectively. The calculated results show that the activation barrier of the “alkyl” pathway is smaller than that of “carbenium” pathway. Consequently, the “alkyl” pathway is the preferential reaction pathway. A new mechanism of methane conversion in the presence of ethene was proposed. In the catalytic cycle, the initial step of methane activation proceeds with the “alkyl” pathway and the Ag+ cation acts as an acceptor of the methyl group, then ethene reacts with the Ag+CH3 group to form propene. In addition, it is found that the Ag+ cations play an important role in the methane activation, compared with the reaction of methane activation over H-ZSM-5.  相似文献   

10.
The density of states (DOS) in the vicinity of the Fermi level controls all transport phenomena at low temperatures near the metal-insulator transition (MIT). The well-known method for DOS-determination on the metallic side of the MIT, the so-called “tunneling spectroscopy”, is inapplicable on the insulating side because of the high sample resistance at low temperatures. In this work a new method for DOS-determination on the insulating side is presented. The method is based on the measurements of variable range hopping (VRH) resistance in magnetic fields. By analogy this method can be called “hopping spectroscopy”.  相似文献   

11.
The high sensitivity but poor specificity of magnetic resonance imaging for detecting breast cancer has stimulated interest in magnetic resonance spectroscopic imaging (MRSI) as a tool to improve specificity and reduce the number of benign biopsies. The challenge of applying 1H MRSI to the diagnosis of cancer in the human breast is the need for robust lipid suppression and a clinically acceptable acquisition time. We present an improved 1H MRSI technique that uses an independently optimized chemical-shift-selective for lipid suppression and weighted elliptical k-space sampling combined with a Hamming filter for improved sampling efficiency.  相似文献   

12.
The use of multi-channel coils can efficiently increase the signal-to-noise ratio (SNR) of magnetic resonance spectroscopy data if the signals from multiple channels are optimally combined. Combining multi-channel signals requires proper alignment of the phases of the signals from each of the elements of the coil and then accurately weighting the summation of those signals. We present a procedure for acquiring proton magnetic resonance spectroscopic imaging (MRSI) data using an eight-channel coil without water suppression and a rapid and robust method that uses unsuppressed water signal as a reference both for aligning the phases and for weighting the summation of signals that originate in the multiple coil elements. We use both computer simulation and in vivo proton MRSI data to demonstrate the advantages of our method for optimizing the SNR of the combined signal compared with the SNRs of signals that were acquired either using a standard volume head coil or using an eight-channel coil with a metabolite signal as the reference for combination.  相似文献   

13.
The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution as small as 0.09 cm(3) for brain MRSI while maintaining adequate SNR and acquisition time. The use of low peak power, dual-band spectral-spatial pulses was also investigated for application to 3 T MRSI of the brain using the body coil for radiofrequency excitation and PA coils for signal reception.  相似文献   

14.
High magnetic fields increase the sensitivity and spectral dispersion in magnetic resonance spectroscopy (MRS). In contrast, spectral peaks are broadened in vivo at higher field strength due to stronger susceptibility-induced effects. Strategies to minimize the spectral line width are therefore of critical importance. In the present study, 1H 2D chemical shift imaging at short echo times was performed in the macaque monkey brain at 7 T. Large brain coverage was obtained at high spatial resolution with voxel sizes down to 50 μl being able to quantify up to nine metabolites in vivo with good reliability. Measured line widths of metabolites decreased from 14.2 to 7.6 Hz with voxel volumes of 3.14 ml to 50 μl (at increased spatial resolution). The line width distribution of the metabolites (7.6±1.6 Hz, ranging from 5.5 to 10 Hz) was considerably smaller compared to that of water (10.6±2.4 Hz) and was also smaller than reported in 1H MRS at 7 T in the human brain. Our study showed that even in well-shimmed areas assumed to have minimal macroscopic susceptibility variations, spectral line widths are tissue-specific exhibiting considerable regional variation. Therefore, an overall improvement of a gross spectral line width — directly correlated with improved spectral quality — can only be achieved when voxel volumes are significantly reduced. Our line width optimization was sufficient to permit clear glutamate (Glu)–glutamine separation, yielding distinct Glu maps for brain areas including regions of greatly different Glu concentration (e.g., ventricles vs. surrounding tissue).  相似文献   

15.
An improved procedure for etching and analysis of alpha tracks induced in LR-115 detectors is proposed with the advantages of simplicity and its relatively low cost. A new type of detector holder was designed to etch and rinse efficiently up to 100 detectors. We develop a simple and reliable methodology with a semiautomatic track count using a Nikon digital camera coupled to a PC and employing software “SCION” freely available on the Internet. Track images are binarized prior the application of software “SCION” so that original track shapes are not distorted, space resolution is improved and track counting has low dependence on focus and illumination level. High discrimination for tracks is achieved when marks and rips perturb the detector surface. An image generator of nuclear tracks is included to study the effect of track overlapping effect on counting.  相似文献   

16.
M. Sotto 《Surface science》1992,260(1-3):235-244
A LEED and AES study on oxygen adsorption on Cu(100) and (h11) faces with 5 h 15 has been performed under various adsorption conditions (220 K T 670 K and 1 × 10−8 P 6 × 10−5 Torr of oxygen). The dependence of adsorption temp on the oxygen surface superstructures is pointed out. At least, three oxygen surface states exist on a Cu(100) face. For low temperature exposures to oxygen, under conditions of slow surface diffusion, on the (100) face, two oxygen surface phases exist: a “four spots” and a c(2 × 2) superstructure, both observed even at saturation coverage; on all the stepped faces, a c(2 × 2) appears and no faceting is observed. For high temperature exposures, on the (100) face, two oxygen superstructures are observed, a “four spots” followed by a (2√2 × √2)R45° at higher coverages; on all the stepped faces, surface diffusion is activated and oxygen induced faceting occurs. The appearance of faceting is associated with the onset of the formation of the (2√2 × √2)R45° structure on the (100) face. The oxygen induced faceting and the oxygen surface meshes are reversible with coverages. At saturation coverage, a non-reversible surface transition between the c(2 × 2) and (2√2 × √2)R45° superstructures is observed at 420 ± 20 K. The importance of impurity traces on the surface meshes is emphasized. Oxygen coverage at saturation is independent of the studied faces and adsorption temperature. Faceting occurs at a critical coverage value, whatever the stepped faces and adsorption temperature are. Models of the oxygen structure on the (h10) stepped faces are discussed.  相似文献   

17.
The nonverbal vocal utterances of seven normally hearing infants were studied within their first year of life with respect to age- and emotion-related changes. Supported by a multiparametric acoustic analysis it was possible to distinguish one inspiratory and eleven expiratory call types. Most of the call types appeared within the first two months; some emerged in the majority of infants not until the 5th (“laugh”) or 7th month (“babble”). Age-related changes in acoustic structure were found in only 4 call types (“discomfort cry,” “short discomfort cry,” “wail,” “moan”). The acoustic changes were characterized mainly by an increase in harmonic-to-noise ratio and homogeneity of the call, a decrease in frequency range and a downward shift of acoustic energy from higher to lower frequencies. Emotion-related differences were found in the acoustic structure of single call types as well as in the frequency of occurrence of different call types. A change from positive to negative emotional state was accompanied by an increase in call duration, frequency range, and peak frequency (frequency with the highest amplitude within the power spectrum). Negative emotions, in addition, were characterized by a significantly higher rate of “crying,” “hic” and “ingressive vocalizations” than positive emotions, while positive emotions showed a significantly higher rate of “babble,” “laugh,” and “raspberry.”  相似文献   

18.
The influence of the concatenation of arbitrary optical multiplexers/demultiplexers (MUX/DEMUXs) on the probability density function (PDF) of the output current of a transparent optical network is assessed. All PDF results obtained analytically are compared with estimates from Monte Carlo simulation and an excellent agreement is achieved.

The non-Gaussian behavior of the PDFs, previously reported by other authors for square-law detectors, is significantly enhanced with the number of nodes increase due to the noise accumulation along the cascade of MUX/DEMUXs. The increase of the MUX/DEMUXs bandwidth and detuning also enhances the PDFs non-Gaussian behavior. The PDF shape variation with the detuning depends strongly on the number of nodes.

Explanations for the Gaussian approximation (GA) accuracy on the assessment of the performance of a concatenation of optical MUX/DEMUXs are also provided. For infinite extinction ratio and tuned MUX/DEMUXs, the GA error probabilities are, in general, pessimistic, due to the inaccurate estimation of the error probability for both bits. For low extinction ratio, the GA is very accurate due to a balance between the error probabilities estimated for the bits “1” and “0.” With the detuning increase, the GA estimates can become optimistic.  相似文献   

19.
We present a framework aimed to reveal directed interactions of activated brain areas using time-resolved fMRI and vector autoregressive (VAR) modeling in the context of Granger causality. After describing the underlying mathematical concepts, we present simulations helping to characterize the conditions under which VAR modeling and Granger causality can reveal directed interactions from fluctuations in BOLD-like signal time courses. We apply the proposed approach to a dynamic sensorimotor mapping paradigm. In an event-related fMRI experiment, subjects performed a visuomotor mapping task for which the mapping of two stimuli (“faces” vs “houses”) to two responses (“left” or “right”) alternated periodically between the two possible mappings. Besides expected activity in sensory and motor areas, a fronto-parietal network was found to be active during presentation of a cue indicating a change in the stimulus-response (S-R) mapping. The observed network includes the superior parietal lobule and premotor areas. These areas might be involved in setting up and maintaining stimulus-response associations. The Granger causality analysis revealed a directed influence exerted by the left lateral prefrontal cortex and premotor areas on the left posterior parietal cortex.  相似文献   

20.
Thin films of Bi2Sr2CaCu2O8 and (Bi, Pb)2Sr2Ca2Cu3O10 have been prepared on monocrystalline (100) MgO substrates, using a laser ablation method with post annealing treatment. The influence of substrate temperature and oxygen pressure during deposition were investigated. SEM observations, EDS analysis, electric and magnetic measurements have been used to characterize the films. Superconducting “2212” films, with Tc(R = 0) at 80–83 K and Jc (50 K) up to 5 × 105 A/cm2, have been currently achieved, while Pb-doped “2223” films exhibit Tc as high as 110 K with Jc = 5 × 104 A/cm2 at 77 K. The effect of annealing at low temperature (350°C) in an argon flow has been studied for the 2212 phase, it shows the influence of the oxygen non-stoichiometry, i.e. of the hole carrier density upon Tc's which can be measured up to 89 K (zero resistance).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号