首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 146 毫秒
1.
Tolnaftate, a thionoester anti‐fungal drug, was subjected to alkaline hydrolysis to produce methyl(m‐tolyl)carbamic acid and β ‐naphthol (tolnaftate impurity A). N‐Methyl‐m‐toluidine, tolnaftate impurity D, was synthesized and structurally elucidated along with tolnaftate alkaline degradation products using IR, H1NMR and MS. Two stability‐indicating HPTLC and RP‐HPLC methods were developed and validated, for the first time, for determination of tolnaftate, its alkaline degradation products and toxic impurities in the presence of methyl paraben, as a preservative in Tinea Cure® cream. The proposed HPTLC method depended on separation of the studied components on TLC silica gel F254 plates using hexane–glacial acetic acid (8:2, v/v) as a developing system and scanning wavelength of 230 nm. The proposed RP‐HPLC method was based on separation of the five components on an Eclipse plus C18 column. The mobile phase used was acetonitrile–water containing 1% ammonium formate (40:60, v/v), with a flow rate of 1 mL/min and detection wavelength of 230 nm. The proposed methods allowed the assay of tolnaftate toxic impurities, β ‐naphthol and N‐methyl‐m‐toluidine, down to 2%, allowing tracing of β ‐naphthol that could be absorbed by the skin causing systemic toxic effects, unlike tolnaftate, indicating the high significance of such determination. International Conference on Harmonization guidelines were followed for validation.  相似文献   

2.
Accurate, selective, sensitive and precise HPTLC‐densitometric and RP‐HPLC methods were developed and validated for determination of bumadizone calcium semi‐hydrate in the presence of its alkaline‐induced degradation product and in pharmaceutical formulation. Method A uses HPTLC‐densitometry, depending on separation and quantitation of bumadizone and its alkaline‐induced degradation product on TLC silica gel 60 F254 plates, using hexane–ethyl acetate–glacial acetic acid (8:2:0.2, v/v/v) as a mobile phase followed by densitometric measurement of the bands at 240 nm. Method B comprises RP‐HPLC separation of bumadizone and its alkaline‐induced degradation product using a mobile phase consisting of methanol–water–acetonitrile (20:30:50, v/v/v) on a Phenomenex C18 column at a flow‐rate of 2 mL/min and UV detection at 235 nm. The proposed methods were successfully applied to the analysis of bumadizone either in bulk powder or in pharmaceutical formulation without interference from other dosage form additives, and the results were statistically compared with the established method. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
In the present study a novel stability‐indicating high‐performance thin‐layer chromatography (HPTLC) method for quantitative determination of silybin in bulk drug and nanoemulsion formulation has been developed and validated on silica using solvent chloroform–acetone–formic acid (9 : 2 : 1 v/v/v) (Rf of silybin 0.46 ± 0.05) in the absorbance mode at 296 nm. The method showed a good linear relationship (r2 ± 0.999) in the concentration range 25–1500 ng per spot. It was found to be linear, accurate, precise, specific, robust and stability‐indicating and can be applied for quality control and standardization of several multi‐component hepatoprotective formulations as well as for stability testing of different dosage forms. The method proposed was also used to investigate the kinetics of acidic and alkaline degradation processes by quantification of drug at different temperature to calculate the activation energy and half‐life for silymarin degradation. Copyright © 2009 John Wiley & Sons, Ltd  相似文献   

4.
We developed novel stability‐indicating HPLC method for simultaneous estimation of 14 impurities in excedrin tablet, a formulation with a combination of acetaminophen, aspirin, and caffeine. In addition, a new impurity that was generated through degradation of aspirin at high temperatures during the accelerated stability conditions was positively identified and confirmed, using liquid chromatography–mass spectrometry technique. The HPLC method was optimized using the Inertsustain C18, 250 × 4.6 mm, 5.0 μm column, employing simple gradient method. Forced degradation studies were performed under acidic, basic, oxidative and thermal conditions to prove the scope and stability‐indicating the nature of the method. The optimized method was validated as per the International Conference on Harmonization guidelines. The HPLC method showed linearity from LOQ concentration to 21 μg mL?1. Precision and intermediate precision values were <5% RSD. The validated HPLC method is currently applied for the routine testing of excedrin tablet formulations in quality control laboratories.  相似文献   

5.
Three new degradation impurities of bupropion were characterized through high performance liquid chromatography coupled to photodiode array detection and to time‐of‐flight mass spectrometry. Bupropion was subjected to the ICH prescribed stress conditions. It degraded to seven impurities (I–VII) in alkaline hydrolytic conditions which were optimally resolved on an XTerra C18 column (250 × 4.6 mm, 5 µm) with a ternary mobile phase comprising ammonium formate (20 mm , pH 4.0), methanol and acetonitrile (75:10:15, v/v). The degradation impurities (III–V and VII) were characterized on the basis of mass fragmentation pattern of drug, accurate mass spectral and photodiode array data of the drug and degradation impurities. Compound V was found to be a known degradation impurity [1‐hydroxy‐1‐(3‐chlorophenyl)propan‐2‐one], whereas III, IV and VII were characterized as 2‐hydroxy‐2‐(3′‐chlorophenyl)‐3,5,5‐trimethylmorpholine, (2,4,4‐trimethyl‐1,3‐oxazolidin‐2‐yl)(3‐chlorophenyl)‐methanone and 2‐(3′‐chlorophenyl)‐3,5,5‐trimethylmorphol‐2‐ene, respectively. Compound III was a known metabolite of the drug. This additional information on the degradation impurities can help in the development of a new stability‐indicating assay method to monitor the stability of the drug product during its shelf‐life as well as in development of a drug product with increased shelf‐life. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
The X‐ray diagnostic agent sodium diatrizoate (DTA) was studied for chemical degradation. The 3,5‐diamino derivative was found to be the alkaline and acidic degradation product. The 3,5‐diamino degradate is also the synthetic precursor of DTA and it is proved to have cytotoxic and mutagenic effects. A sensitive, selective and precise high‐performance liquid chromatographic stability‐indicating method for the determination of DTA in the presence of its acidic degradation product and in pharmaceutical formulation was developed and validated. Owing to the high toxicity of the degradation product, the kinetics of the acidic degradation process was monitored by the developed RP‐HPLC method. The reaction was found to follow pseudo‐first order kinetics. The kinetic parameters such as rate constant (K ) and half‐life (t ½) were calculated under different temperatures and acid concentrations; activation energy was estimated from the Arrhenius plot. The developed RP‐HPLC method depends on isocratic elution of a mobile phase composed of methanol–water (25:75 v /v; pH adjusted with phosphoric acid), and UV detection at 238 nm. The method showed good linearity over a concentration range of 2–100 μg/mL with mean percentage recovery of 100.04 ± 1.07. The selectivity of the proposed method was tested using laboratory‐prepared mixtures. The proposed method has been successfully applied to the analysis of DTA in pharmaceutical dosage forms without interference from other dosage form additives and the results were statistically compared with the official USP method. Validation of the proposed method was performed according to International Conference on Harmonization guidelines.  相似文献   

7.
Two sensitive and reproducible methods are described for the quantitative determination of dasatinib in the presence of its degradation products. The first method was based on high performance thin layer chromatography (HPTLC) followed by densitometric measurements of their spots at 280 nm. The separation was on HPTLC aluminium sheets of silica gel 60 F254 using toluene:chloroform (7.0:3.0, v/v). This system was found to give compact spots for dasatinib after development (R F value of 0.23 ± 0.02). The second method was based on high performance liquid chromatography (HPLC) of the drug from its degradation products on reversed phase, PerfectSil column [C18 (5 μm, 25 cm × 4.6 mm, i.d.)] at ambient temperature using mobile phase consisting of methanol:20 mM ammonium acetate with acetic acid (45:55, v/v) pH 3.0 and retention time (t R = 8.23 ± 0.02 min). Both separation methods were validated as per the ICH guidelines. No chromatographic interference from the tablet excipients was found. Dasatinib was subjected to acid–alkali hydrolysis, oxidation, dry heat, wet heat and photo-degradation. The drug was susceptible to acid–alkali hydrolysis and oxidation. The drug was found to be stable in neutral, wet heat, dry heat and photo-degradation conditions. As the proposed analytical methods could effectively separate the drug from its degradation products, they can be employed as stability indicating.  相似文献   

8.
A novel reversed‐phase HPLC method was developed and validated for the assay of tetracycline hydrochloride and the limit of 4‐epianhydrotetracycline hydrochloride impurity in tetracycline hydrochloride commercial bulk and pharmaceutical products. The method employed L1 (3 µm, 150 × 4.6 mm) columns, a mobile phase of 0.1% phosphoric acid and acetonitrile at a flow rate of 1.0 mL/min, and detection at 280 nm. The separation was performed in HPLC gradient mode. Forced degradation studies showed that tetracycline eluted as a spectrally pure peak and was well resolved from its degradation products. The fast degradation of tetracycline hydrochloride and 4‐epianhydrotetracycline hydrochloride in solution was retarded by controlling the autosampler temperature at 4 °C and using 0.1% H3PO4 as diluent. The robustness of the method was tested starting with the maximum variations allowed in the US Pharmacopeia (USP) general chapter Chromatography <621>. The method was linear over the range 80–120% of the assay concentration (0.1 mg/mL) for tetracycline hydrochloride and 50–150% of the acceptance criteria specified in the individual USP monographs for 4‐epianhydrotetracycline hydrochloride. The limit of quantification for 4‐epianhydrotetracycline hydrochloride was 0.1 µg/mL, 20 times lower than the acceptance criteria. The method was specific, precise, accurate and robust. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
《印度化学会志》2021,98(11):100215
We report herein an accurate, precise, and economical stability indicating high performance thin layer chromatographic (HPTLC) method developed to assess the safety of olanzapine in pharmaceutical formulations. Olanzapine was subjected to forced degradation studies to assess the effect of environmental conditions on its stability. Stress conditions such as hydrolysis under acidic and alkaline environment, degradation and oxidation by heat, light and air were used to study the stability of olanzapine. Mobile phase comprising of toluene: methanol (5:5 v/v) and aluminum plate pre-coated with silica gel 60 F254 as a stationary phase were used for the development of chromatogram by HPTLC technique. Densitometric analysis of olanzapine carried out at 297 ​nm gave sharp symmetrical peak with Rf value of 0.50 and a satisfactory baseline resolution for all components. The drug was found to undergo degradation under acidic, alkaline and oxidative conditions. A single distinct peak in acidic and alkaline media while two peaks obtained as a result of oxidative degradation were well resolved along with the parent drug. The degradation products and parent drug showed significantly different Rf values. The developed HPTLC method gave quick and reproducible results for the olanzapine content in the tablets. The mean recoveries were 100.75% which confirms accuracy of the proposed method. The method was further validated for specificity, ruggedness and robustness. Based on the results, it can be suggested that the developed HPTLC method is quite efficient in separating the olanzapine from its degradation products; hence it can be used by pharmaceutical industries and regulatory bodies for the routine analysis of olanzapine in various pharmaceutical dosage forms.  相似文献   

10.
Two selective and accurate chromatographic methods are presented for simultaneous quantitation of spironolactone (SP) and furosemide (FR) and canrenone (CN), the main degradation product and the main active metabolite of SP. Method A was HPTLC, where separation was completed on silica gel HPTLC F254 plates using ethyl acetate–triethylamine–acetic acid (9:0.7:0.5, by volume) as a developing system and UV detection at 254 nm. Method B was a green isocratic RP‐HPLC utilizing a C18 (4.6 × 100 mm) column, the mobile phase consisting of ethanol–deionized water (45: 55, v/v) and UV estimation at 254 nm. Adjustment of flow rate at 1 mL/min and pH at 3.5 with glacial acetic acid was done. Regarding the greenness profile, the proposed RP‐HPLC method is greener than the reported one. ICH guidelines were followed to validate the developed methods. Successful applications of the developed methods were revealed by simultaneous determination of FR, SP and CN in pure forms and plasma samples in the ranges of 0.2–2, 0.05–2.6 and 0.05–2 μg/band for method A and 5–60, 2–60 and 2–60 μg/mL for method B for FR, SP and CN, respectively.  相似文献   

11.
A validated stability‐indicating HPLC method was established, and comprehensive stress testing of ivabradine, a cardiotonic drug, was carried out as per ICH guidelines. Ivabradine was subjected to acidic, basic and neutral hydrolysis, oxidation, photolysis and thermal stress conditions, and the resulting degradation products were investigated by LC‐PDA and LC‐HR‐MS/MS. The drug was found to degrade in acid and base hydrolysis. An efficient and selective stability assay method was developed on Phenomenex Luna C18 (250 × 4.6 mm, 5.0 µm) column using ammonium formate (10 mM, pH 3.0) and acetonitrile as mobile phase at 30 °C in gradient elution mode. The flow rate was 0.7 ml/min and detection wavelength was 286 nm. A total of five degradation products (I‐1 to I‐5) were identified and characterized by LC‐HR‐MS/MS in combination with accurate mass measurements. The drug exhibited different degradation behaviour in HCl and H2SO4 hydrolysis conditions. It is a unique example where two of the five degradation products in HCl hydrolysis were absent in H2SO4 acid hydrolysis. The present study provides guidance to revise the stress test for the determination of inherent stability of drugs containing lactam moiety under hydrolytic conditions. Most probable mechanisms for the formation of degradation products have been proposed on the basis of a comparison of the fragmentation pattern of the drug and its degradation products. In silico toxicity revealed that the degradation products ( I‐2 to I‐5 ) were found to be severe irritants in case of ocular irritancy. The analytical assay method was validated with respect to specificity, linearity, range, precision, accuracy and robustness. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
Gliquidone (GQ) is an oral hypoglycemic agent, belonging to second‐generation sulfonylurea derivatives. New high‐performance thin‐layer chromatography (HPTLC) and ultra‐performance liquid chromatography (UPLC) methods have been developed and validated and used for complete stability study of GQ following International Conference on Harmonization guidelines. GQ was subjected to stress and forced degradation under hydrolytic, oxidative and photolytic conditions. The drug was found to be unstable under acidic, alkaline and oxidative conditions with the formation of gliquidone sulfonamide (GQS), while a marked stability was confirmed under thermal and photolytic stress conditions. GQS is the British pharmacopeial impurity A of GQ and also considered as its synthesis intermediate. The developed chromatographic methods have been utilized for anticipating the degradation behavior of GQ under the studied conditions and then used for quantitation of GQ and GQS either in their pure forms or in laboratory prepared mixtures. The methods were successfully applied to GQ in pharmaceutical formulation. The methods have the advantages of being sensitive and less time consuming compared with the reported methods. The obtained results were statistically compared with a reported HPLC method showing no significant difference regarding both accuracy and precision.  相似文献   

13.
A rapid, simple, stability‐indicating forced degradation study of clobetasol 17‐propionate was conducted using RP‐HPLC. The method was used to analyze clobetasol 17‐propionate in methanol, propylene glycol, and a cream formulation. Isocratic elution of clobetasol and its degradation products was achieved using a Nova‐Pak® 4 μm C18 150 mm × 3.9 mm id cartridge column and a mobile phase of methanol: water (68:32 v/v) at a flow rate of 0.9 mL min?1. Quantitation was achieved with UV detection at 239 nm. Nondegraded clobetasol was eluted at a retention time of 6.0 min. Clobetasol 17‐propionate was subjected to different stress conditions viz., acidic, basic, heat, oxidation, light, and neutral hydrolysis. The greatest degradation occurred under strong base and oxidative conditions. Strong base‐degraded clobetasol produced additional peaks at retention times of 1.8, 4.0, 5.0, and 8.0 min and clobetasol oxidation degradation peaks eluted at 2.2 and 24 min. Complete validation was performed for linearity, accuracy, and precision over the concentration range 0.15–15 μg mL?1. All data were analyzed statistically and this RP‐HPLC method proved to be accurate, precise, linear, and stability indicating for the quantitation of clobetasol 17‐propionate in methanol, propylene glycol, and cream formulations.  相似文献   

14.
A rapid, accurate and sensitive thin‐layer chromatography (TLC) method with densitometric detection has been developed and validated for the determination of cefepime in pharmaceuticals. Chromatographic separation was achieved on a silica gel TLC F254 plates with a mobile phase consisting of ethanol–2‐propanol–glacial acetic acid 99.5%–water (4:4:1:3, v/v). Densitometric detection was carried out at wavelength of 266 nm in reflectance/absorbance mode. The validation of the method was found to be satisfactory with high accuracy (from 99.24 to 101.37%) and precision (RSD from 0.06 to 0.36%). Additionally, the stability of cefepime in solution was investigated, including the effect of pH, temperature and incubation time. Favorable retention parameters (Rf, Rs, α) were obtained under the developed conditions, which guaranteed good separation of the studied components. The degradation process of cefepime hydrochloride was described by kinetic and thermodynamic parameters (k, t0.1, t0.5 and Ea). Moreover, the chemical properties of degradation products were characterized by the Rf values, absorption spectra, HPLC‐MS/MS and TLC‐densitometry analysis. As the method could effectively separate the active substance from its main degradation product (1‐methylpyrrolidine), it can be employed as a method to indicate the stability of this drug. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Fluorometholone (FLM) and Sodium Cromoglycate (CMG) are co-formulated in ophthalmic preparation and showed marked instability under different conditions. Two specific, sensitive and precise stability-indicating chromatographic methods have been developed and validated for their determination in the presence of their degradation products and FLM impurity. Ten components were efficiently separated by them. The first method was HPTLC-spectrodensitometry, where the separation was achieved using silica gel 60?F254 HPTLC plates and developing system of ethyl acetate: methanol (9:1, v/v). The second method was a reversed phase HPLC associated with kinetic study of the degradation process and was successfully applied for determination of the studied compounds in spiked rabbit aqueous humor. The mobile phase was acetonitrile: methanol: 0.05?M potassium dihydrogenphosphate (0.1% trimethylamine); pH 2.5, adjusted with orthophosphoric acid (20: 30: 50, by volume). In both methods, the separated components were detected at 240?nm and system suitability was checked. Good correlation was obtained in the range of 0.10–24.00 and 0.20–48.00?µg band?1, for FLM and CMG by HPTLC. While for HPLC, the linearity ranges from 0.01–50.00 and 0.05–50.00?µg?mL?1 for both drugs. The methods were applied in pharmaceutical formulation, where they were compared to the reported method with no significant difference.  相似文献   

16.
The current research work envisages an analytical quality by design‐enabled development of a simple, rapid, sensitive, specific, robust and cost‐effective stability‐indicating reversed‐phase high‐performance liquid chromatographic method for determining stress‐induced forced‐degradation products of sorafenib tosylate (SFN). An Ishikawa fishbone diagram was constructed to embark upon analytical target profile and critical analytical attributes, i.e. peak area, theoretical plates, retention time and peak tailing. Factor screening using Taguchi orthogonal arrays and quality risk assessment studies carried out using failure mode effect analysis aided the selection of critical method parameters, i.e. mobile phase ratio and flow rate potentially affecting the chosen critical analytical attributes. Systematic optimization using response surface methodology of the chosen critical method parameters was carried out employing a two‐factor–three‐level–13‐run, face‐centered cubic design. A method operable design region was earmarked providing optimum method performance using numerical and graphical optimization. The optimum method employed a mobile phase composition consisting of acetonitrile and water (containing orthophosphoric acid, pH 4.1) at 65:35 v/v at a flow rate of 0.8 mL/min with UV detection at 265 nm using a C18 column. Response surface methodology validation studies confirmed good efficiency and sensitivity of the developed method for analysis of SFN in mobile phase as well as in human plasma matrix. The forced degradation studies were conducted under different recommended stress conditions as per ICH Q1A (R2). Mass spectroscopy studies showed that SFN degrades in strongly acidic, alkaline and oxidative hydrolytic conditions at elevated temperature, while the drug was per se found to be photostable. Oxidative hydrolysis using 30% H2O2 showed maximum degradation with products at retention times of 3.35, 3.65, 4.20 and 5.67 min. The absence of any significant change in the retention time of SFN and degradation products, formed under different stress conditions, ratified selectivity and specificity of the systematically developed method.  相似文献   

17.
Quetiapine fumarate (QUE) is an antipsychotic agent with a chemical structure that is susceptible to degradation; therefore, it is important to study its stability using appropriate analytical tools. Knowledge of the stability profile of a drug is important because chemical degradation of its active component often results in a loss of potency, affecting its efficacy and safety. This current work reports degradation studies of QUE as drug substance, under different stress conditions such as oxidation, hydrolysis, heat, humidity and photolysis, by a stability‐indicating LC method. The chemical stability was evaluated using a simple HPLC/diode array detection method, with a core‐shell C18 column under isocratic conditions, which allows the separation of all primary degradation products (DPs) in a short run time. QUE was mainly degraded under oxidative and hydrolytic conditions, with the formation of three and two DPs, respectively, which were identified by electrospray ionization–tandem mass spectrometry. The method was properly validated in terms of linearity, accuracy, precision, selectivity, robustness and quantitation limit. Commercial tablets containing 25 mg of QUE were quantified, with results obtained within the United States Pharmacopeia limits. The proposed method is suitable to assess the stability and perform routine analysis of QUE in pharmaceutical samples.  相似文献   

18.
Carbapenems show recognized instability in aqueous solutions; therefore some care must be taken in their handling and preparation and their use in the hospital environment. The stability and degradation products of imipenem were investigated from conditions that simulate its clinical use. For this, a simple stability‐indicating method by HPLC‐DAD was validated with a focus on the quantitation of drug concentration remaining from infusion solutions (sodium chloride 0.9% and glucose 5%). The degradation products formed were identified by high‐resolution mass spectrometry (ESI‐Q‐TOF‐MS/MS), with detection of the [M + H]+ ions at m/z 318 (DP‐1), m/z 599 (DP‐2) and m/z 658 (DP‐3). The most probable elemental compositions were obtained with a high degree of confidence, where the error between the masses observed and calculated was 1.25 ppm for DP‐1, ?0.33 ppm for DP‐2 and 1.82 ppm for DP‐3. The DP‐1 degradation product resulted from cleavage of the β‐lactam ring; DP‐2 corresponded to the drug dimer; and DP‐3 was generated from the interaction between imipenem and cilastatin. The proposed method provides a safe and reliable alternative for the quantitation of imipenem, and the stability data obtained by ESI‐Q‐TOF help in understanding the drug behavior under the conditions of clinical use.  相似文献   

19.
Reversed phase‐high performance liquid chromatography (RP‐HPLC), thin layer chromatography (TLC) densitometry and first derivative spectrophotometry (1D) techniques are developed and validated as a stability‐indicating assay of ezetimibe in the presence of alkaline induced degradation products. RP‐HPLC method involves an isocratic elution on a Phenomenex Luna 5μ C18 column using acetonitrile: water: glacial acetic acid (50:50:0.1 v/v/v) as a mobile phase at a flow rate of 1.5 mL/min. and a UV detector at 235 nm. TLC densitometric method is based on the difference in Rf‐values between the intact drug and its degradation products on aluminum‐packed silica gel 60 F254 TLC plates as stationary phase with isopropanol: ammonia 33% (9:1 v/v) as a developing mobile phase. On the fluorescent plates, the spots were located by fluorescence quenching and the densitometric analysis was carried out at 250 nm. Derivative spectrophotometry, the zero‐crossing method, ezetimibe was determined using first derivative at 261 nm in the presence of its degradation products. Calibration graphs of the three suggested methods are linear in the concentration ranges 1–10 mcg/mL, 0.1–1 mg/mL and 1–16 mcg/mL with a mean percentage accuracy of 99.05 ± 0.54%, 99.46 ± 0.63% and 99.24 ± 0.82% of bulk powder, respectively. The three proposed methods were successfully applied for the determination of ezetimibe in raw material and pharmaceutical dosage form; the results were statistically analyzed and compared with those obtained by the reported method. Validation parameters were determined for linearity, accuracy and precision; selectivity and robustness and were assessed by applying the standard addition technique.  相似文献   

20.
A forced degradation study on ropinirole hydrochloride in bulk and in its modified release tablets was conducted under the conditions of hydrolysis, oxidation and photolysis in order to develop an isocratic stability-indicating LC-UV method for quantification of the drug in tablets. An impurity peak in standard solution was found to increase under acidic and neutral hydrolytic conditions while another degradation product was formed under alkaline condition. The drug and its degradation products were optimally resolved on a Hypersil C18 column with mobile phase composed of diammonium hydrogen orthophosphate (0.05 M; pH 7.2), tetrahydrofuran and methanol (80:15:5% v/v) at a flow rate of 1.0 mL min?1 at 30 °C using 250 nm as detection wavelength. The method was linear in the range of 0.05–50 μg mL?1 drug concentrations. The %RSD of inter- and intra-day precision studies was <1. The system suitability parameters remained unaffected during quantification of the drug on three different LC systems. Excellent recoveries (101.59–102.28%) proved that the method was sufficiently accurate. The LOD and LOQ were found to be 0.012 and 0.040 μg mL?1, respectively. Degradation behaviour of the drug in both bulk and tablets was similar. The drug was very unstable to hydrolytic conditions but stable to oxidative and photolytic conditions. The method can be used for rapid and accurate quantification of ropinirole hydrochloride in tablets during stability testing. Based on chemical reactivity of ropinirole in different media, the degradation products were suspected to be different from the known impurities of the drug.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号