首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
An interlaboratory trial for the determination of patulin in apple juice and fruit puree was conducted, involving 17 participants representing a cross section of industry, official food control, and research facilities. Mean recoveries reported ranged from 74 (10 ng/g) to 62% (25 ng/g) for apple juice and from 72 (25 ng/g) to 74% (10 ng/g) for fruit puree. Based on results for spiked samples (blind pairs at 2 levels), as well as naturally contaminated samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) in juice ranged from 8.0 to 14.3% and in puree from 3.5 to 9.3%. The relative standard deviation for reproducibility (RSD(R)) in juice ranged from 19.8 to 39.5% and in puree from 12.5 to 35.2%, reflecting HORRAT values from 0.6 to 1.0 for juice and 0.4 to 0.9 for puree. The method showed acceptable within-laboratory and between-laboratory precision for each matrix, as required by current European legislation.  相似文献   

2.
Eight collaborating laboratories assayed 7 blind duplicate pairs of foods for polydextrose content. The 7 test sample pairs ranged from low (2%) to high (95%) levels. The following foods were prepared with polydextrose mixed into the other ingredients and then baked, cooked, or otherwise prepared: milk chocolate candy, iced tea, sugar cookie, grape jelly, soft jellied candy, and powdered drink mix. Collaborators received a polydextrose standard to develop a calibration curve. The method determined polydextrose by ion chromatography, after removal of interfering food components (high molecular weight solubles). Repeatability standard deviations (RSDr) ranged from 3.93 to 9.04%; reproducibility standard deviations (RSDR) ranged from 4.48 to 14.06%. The average recovery was 94%.  相似文献   

3.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic method for determination of aflatoxin M1 in milk at proposed European regulatory limits. The test portion of liquid milk was centrifuged, filtered, and applied to an immunoaffinity column. The column was washed with water, and aflatoxin was eluted with pure acetonitrile. Aflatoxin M1 was separated by reversed-phase liquid chromatography (LC) with fluorescence detection. Frozen liquid milk samples both naturally contaminated with aflatoxin M1 and blank samples for spiking, were sent to 12 collaborators in 12 different European countries. Test portions of samples were spiked at 0.05 ng aflatoxin M1 per mL. After removal of 2 noncompliant sets of results, the mean recovery of aflatoxin M1 was 74%. Based on results for spiked samples (blind pairs at 1 level) and naturally contaminated samples (blind pairs at 3 levels) the relative standard deviation for repeatability (RSDr) ranged from 8 to 18%. The relative standard deviation for reproducibility (RSDR) ranged from 21 to 31%. The method showed acceptable within- and between-laboratory precision data for liquid milk, as evidenced by HORRAT values at the low level of aflatoxin M1 contamination.  相似文献   

4.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B, in a milk powder based infant formula at a possible future European regulatory limit (0.1 ng/g). The test portion was extracted with methanol-water (8 + 2 [v + v]), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. The separation and determination of the aflatoxin B1 was performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) involving bromination. PCD was achieved with either pyridinum hydrobromide perbromide (PBPB) or an electrochemical (Kobra) cell by addition of bromide to the mobile phase. The baby food (infant formula) test samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 14 laboratories in 13 different European countries. Test portions were spiked at levels of 0.1 and 0.2 ng/g for aflatoxin B1. Recoveries ranged from 101 to 92%. Based on results for spiked test samples (blind pairs at 2 levels) and naturally contaminated test samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 3.5 to 14%. The relative standard deviation for reproducibility (RSDR) ranged from 9 to 23%. Nine participants used PBPB derivatization, and  相似文献   

5.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for determination of aflatoxin B1 in cattle feed at a possible future European regulatory limit (1 ng/g). The test portion was extracted with acetone-water (85 + 15), filtered, diluted with water, and applied to an immunoaffinity column. The column was washed with water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase liquid chromatography (RP-LC) and detected by fluorescence after post column derivatization (PCD) involving bromination. PCD was achieved with either pyridinium hydrobromide perbromide (PBPB), used by 14 laboratories, or an electrochemical cell and addition of bromide to the mobile phase, used by 7 laboratories. Both derivatization techniques were not significantly different when compared by the t-test; the method was statistically evaluated for all laboratories together (bromination and PBPB). The cattle feed samples, both spiked and naturally contaminated with aflatoxin B1, were sent to 21 laboratories in 14 different countries (United States, Japan, and Europe). Test portions were spiked at levels of 1.2 and 3.6 ng/g for aflatoxin B1. Recoveries ranged from 74 to 157%. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 5.9 to 8.7%. The relative standard deviation for reproducibility (RSDR) ranged from 17.5 to 19.6%. The method showed acceptable within- and between-laboratory precision for this matrix, as evidenced by HORRAT values, at the target levels of determination for aflatoxin B1. No major differences in RSD were observed, showing that the composition of the feeds was not a factor for the samples tested and that the method was applicable for all materials used.  相似文献   

6.
An interlaboratory study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 levels in corn samples, enforced by European Union legislation. A test portion was extracted with methanol-water (80 + 20); the extract was filtered, diluted with phosphate-buffered saline solution, filtered on a microfiber glass filter, and applied to an immunoaffinity column. The column was washed with deionized water to remove interfering compounds, and the purified aflatoxin B1 was eluted with methanol. Aflatoxin B1 was separated and determined by reversed-phase LC with fluorescence detection after either pre- or postcolumn derivatization. Precolumn derivatization was achieved by generating the trifluoroacetic acid derivative, used by 8 laboratories. The postcolumn derivatization was achieved either with pyridinium hydrobromide perbromide, used by 16 laboratories, or with an electrochemical cell by the addition of bromide to the mobile phase, used by 5 laboratories. The derivatization techniques used were not significantly different when compared by the Student's t-test; the method was statistically evaluated for all the laboratories. Five corn sample materials, both spiked and naturally contaminated, were sent to 29 laboratories (22 Italian and 7 European). Test portions were spiked with aflatoxin B1 at levels of 2.00 and 5.00 ng/g. The mean values for recovery were 82% for the low level and 84% for the high contamination level. Based on results for spiked samples (blind pairs at 2 levels) as well as naturally contaminated samples (blind pairs at 3 levels), the values for relative standard deviation for repeatability (RSDr) ranged from 9.9 to 28.7%. The values for relative standard deviation for reproducibility (RSDR) ranged from 18.6 to 36.8%. The method demonstrated acceptable within- and between-laboratory precision for this matrix, as evidenced by the HorRat values.  相似文献   

7.
Interlaboratory performance statistics was determined for a method developed to measure the resistant starch (RS) content of selected plant food products and a range of commercial starch samples. Food materials examined contained RS (cooked kidney beans, green banana, and corn flakes) and commercial starches, most of which naturally contain, or were processed to yield, elevated RS levels. The method evaluated was optimized to yield RS values in agreement with those reported for in vivo studies. Thirty-seven laboratories tested 8 pairs of blind duplicate starch or plant material samples with RS values between 0.6 (regular maize starch) and 64% (fresh weight basis). For matrixes excluding regular maize starch, repeatability relative standard deviation (RSDr) values ranged from 1.97 to 4.2%, and reproducibility relative standard deviation (RSDR) values ranged from 4.58 to 10.9%. The range of applicability of the test is 2-64% RS. The method is not suitable for products with <1% RS (e.g., regular maize starch; 0.6% RS). For such products, RSDr and RSDR values are unacceptably high.  相似文献   

8.
A interlaboratory study was conducted to evaluate a liquid chromatographic (LC) procedure for the determination of total vitamin C in foods at levels of 5-60 mg/100 g. Emphasis was placed on fruit juices, although selected foods were also included in the study. Following dissolution of sample in water, endogenous dehydroascorbic acid was converted to ascorbic acid by precolumn reduction with dithiothreitol at neutral pH. Total ascorbate was determined by C18 reversed-phase LC with a phosphate eluent at pH 2.5, incorporating dithiothreitol to maintain vitamin C in the reduced form, and UV detection at 254 nm. Seven types of fruit juices and foods were tested by 19 collaborators in 7 countries. Three duplicate juices and foods met the criteria for Youden pairs and yielded repeatability relative standard deviation of 5.80-14.66%. Reproducibility relative standard deviation ranged from 6.36 to 35.54% (n = 10) with HORRAT values of 0.82-4.04. The LC method is suitable for routine use in fruit products and foods containing > 5 mg/100 g vitamin C and is recommended for further validation by AOAC INTERNATIONAL and International Fruit Juice Union.  相似文献   

9.
A high-resolution proton nuclear magnetic resonance (NMR) method for determining the concentration (mg/g) of docosahexaenoic acid (DHA), the molar proportion (mol%) of DHA, and the molar proportion of total n-3 fatty acids in fish oils was validated by an IUPAC interlaboratory study (the Commission VI-6 on Oils, Fats, and Derivatives WG 3/98). Thirteen laboratories from 5 countries tested 6 pairs of blind duplicate fish oils: a refined tuna oil, 2 extracted tuna oils, an extracted bonito oil, an extracted salmon oil, and an extracted sardine oil ranging from 9 to 30 mol% DHA and from 20 to 35 mol% n-3 fatty acids. Before 1 D-proton NMR measurements with 300-500 MHz instruments, oil samples were weighed and diluted with deuterochloroform solution containing ethylene glycol dimethyl ether as internal standard. To achieve precise performance, a detailed procedure for signal area measurement was described in the protocol, and all participants were instructed about the critical importance of following the protocol. Statistical performances with invalid and outlier data removed were as follows: repeatability relative standard deviations (RSDr) ranged from 0.91 to 2.62% and reproducibility relative standard deviation (RSDR) ranged from 1.73 to 4.27% for DHA concentration (mg/g); RSDr ranged from 0.39 to 2.06%, and RSDR ranged from 0.59 to 3.46% for mol% DHA; RSDr ranged from 0.23 to 0.90% and RSDR ranged from 0.85 to 2.01 % for mol% total n-3 fatty acids. The method is expected to be recommended by IUPAC.  相似文献   

10.
Fourteen collaborating laboratories assayed maleic hydrazide (MH), 6-hydroxypyridazin-3(2H)-one, in technical and formulated products by reversed-phase liquid chromatography (LC) with sulfanilic acid as an internal standard. The active MH in the samples (6 lots) ranged from 16% (expressed as the potassium salt) to 98% (MH in the technical). A small amount of 1 M KOH was added to the technical MH and analytical standards to create the potassium salt of the analyte which is soluble in water. Test samples and standards were extracted with water containing the internal standard before analysis by LC on a C8 column with an ion-pairing eluting solution and UV detection at 254 nm. The concentration of MH was calculated by comparing the peak area response ratios of the analyte and the internal standard with those in the analytical standard solution. Eleven laboratories weighed each test sample twice with single analysis. Three laboratories weighed each sample once and made duplicate injections on the LC system. The data were analyzed using the 11 laboratories' results. A second data analysis was done including all laboratory results using a Youden pair approach, selecting one of 2 duplicate assay values randomly for each laboratory and sample. In the first data analysis, the repeatability standard deviation ranged from 0.07 to 1.39%; reproducibility standard deviation ranged from 0.22 to 1.39%. In the second data analysis (using all laboratory data), repeatability standard deviation ranged from 0.09 to 0.86%; reproducibility standard deviation ranged from 0.22 to 1.31%.  相似文献   

11.
The accuracy, precision, and reproducibility of a rapid method for determination of fluoride in wine, using a fluoride selective ion electrode, were established by a collaborative study involving 12 laboratories, 5 in Europe and 7 in the United States. The laboratories assayed 6 Youden pairs of fluoride-fortified, red and white wine samples with fluoride concentrations ranging from 0.2 to 3.0 mg/L. The relative standard deviations of repeatability ranged from 1.94 to 4.88%; relative standard deviations of reproducibility ranged from 4.15 to 18.40%. HORRAT values ranged from 0.30 to 0.97. The average recovery was 99.97%. Based on the statistical results of this collaborative study, the Study Director recommends that this method be adopted First Action.  相似文献   

12.
An interlaboratory study was performed to evaluate the effectiveness of a headspace gas chromatography (GC) method for the determination of 1,3-dichloro-propan-2-ol (1,3-DCP) in soy sauce and related products at levels above 5 ng/g. The test portion is mixed with an internal standard (d5-1,3-DCP) and ammonium sulfate in a sealed headspace vial. After achieving equilibrium, the headspace is sampled either by gas-tight syringe or solid-phase microextraction (SPME) and analyzed by GC with mass spectrometric detection. 1,3-DCP is detected in the selected-ion mode (monitoring m/z 79 and 81 for 1,3-DCP and m/z 82 for the deuterated internal standard) and quantified by measurement against standards. Test materials comprising soy, dark soy, mushroom soy, and teriyaki sauces, both spiked and naturally contaminated, were sent to 9 laboratories in Europe, Japan, and the United States; of these, 5 used SPME and 4 used syringe headspace analysis. Test portions were spiked at 5.0, 10.0, 20.0, 100.0, and 500.0 ng/g. The average recovery for spiked blank samples was 108% (ranging from 96-130%). Based on results for spiked samples (blind pairs at 5, 10, 20, 100, and 500 ng/g) as well as a naturally contaminated sample (split-level pair at 27 and 29 ng/g), the relative standard deviation for repeatability (RSDr) ranged from 2.9-23.2%. The relative standard deviation for reproducibility (RSDR) ranged from 20.9-35.3%, and HorRat values of between 1.0 and 1.6 were obtained.  相似文献   

13.
The quantification at trace levels using mass selective detection and internal standards was tested. In a collaborative study the participants determined the concentrations of seven pesticides in an acetone solution and in two spiked potable water extracts. The relative standard deviation ranged from 7 to 20.5%, the average recovery was 101.4%.  相似文献   

14.
Fifteen collaborating laboratories were sent 9 samples of citrus juice mixtures as blind duplicates for determination of naringin and neohesperidin by liquid chromatography. Two sample pairs were 100% orange juice and did not contain any naringin or neohesperidin. The remaining 7 sample pairs contained naringin at levels ranging from 3.9 to 46.5 ppm and neohesperidin at levels ranging from 0.14 to 35.6 ppm. Five sample pairs consisted of orange juice mixtures containing 1, 3, and 5% grapefruit juice; 5% sour orange; and 5% K-Early citrus variety. Two sample pairs were orange juice spiked with naringin, neohesperidin, sodium benzoate, and potassium sorbate. Data were received from 13 laboratories. Data from 1 collaborator were eliminated because the method protocol was not followed. Neohesperidin values from another laboratory were also not used because of problems with a coeluting component. Repeatability relative standard deviations ranged from 2.95 to 15.23% for naringin and from 3.00 to 11.74% for neohesperidin. Reproducibility relative standard deviations ranged from 11.34 to 31.94% for naringin and from 10.45 to 26.17% for neohesperidin. The method is reliable for detecting the presence of grapefruit juice in orange juice as indicated by a finding of > or =10 ppm naringin and < or =2 ppm neohesperidin. The method was adopted First Action by AOAC INTERNATIONAL.  相似文献   

15.
Ramoplanin is a novel glycolipodepsipeptide antibiotic, currently undergoing clinical trials. This method describes the determination of ramoplanin by direct injection of human urine into a coupled-column liquid chromatographic system. An internal-surface reversed-phase column has been used for on-line sample clean-up and enrichment. Analytical separation of ramoplanin and MDL 62,456 used as internal standard, has been achieved on a ABZ+ reversed-phase column with ammonium acetate buffer-acetonitrile-methanol according to a gradient profile. Analytes were detected by their UV absorbance at 270 nm. The limit of quantitation was 0.1 microgram/ml urine and the limit of detection was found to be 0.035 microgram/ml, corresponding to 13.7 pmol/ml. Linearity was determined in the range 0.1-2 micrograms/ml. Precision (relative standard deviation) ranged from 0.71 to 8.75% and the accuracy from -9.9 to 11.6%. Different human sources were tested and no interference between analytes and urine constituents was observed. The method is simple and rapid, requiring a total analysis time of 35 min per sample and reaching greater selectivity and accuracy than microbiological assays.  相似文献   

16.
Thirteen laboratories participated in a collaborative study to validate a colorimetric assay for determining neutral lactase activity in industrial enzyme preparations. Each laboratory received 5 duplicate samples with activity levels of 2000 and 5000 neutral lactase units provided by 4 commercial suppliers. Two laboratories did not return results. Method performance was calculated according to AOAC guidelines. From the 11 remaining laboratories, 3 were excluded from statistical analysis because of invalid data determined during initial review by Youden pair, value versus laboratory. Repeatability relative standard deviation (RSDr) values ranged from 3.20 to 8.62%, and reproducibility relative standard deviation (RSDR) values ranged from 8.77 to 16.35%. With outliers excluded, RSDr values ranged from 2.94 to 5.01%, and RSDR values ranged from 7.50 to 13.84%. The colorimetric enzymatic method for determining neutral lactase activity in industrial enzyme preparations has been adopted first action by AOAC INTERNATIONAL.  相似文献   

17.
Fourteen laboratories participated in a collaborative study (coded fyt9404) and 13 laboratories participated in a study (coded fyt9410) to validate a colorimetric assay for determination of microbial phytase activity in feed. For each study, all laboratories received 6 laboratory samples provided by one commercial supplier (phytase activity levels within the range of 200-400 per kg) to be analyzed in duplicate. Method performance was calculated and statistical calculations were executed according to AOAC guidelines. Results from 3 laboratories for study fyt9404 and from one laboratory for study fyt9410 were excluded from statistical analysis because of invalid data determined during initial review by Youden pair, value versus laboratory. For study fyt9404, repeatability relative standard deviation (RSDr) values ranged from 6.2 to 8.6%, and reproducibility relative standard deviation (RSDR) values ranged from 14.1 to 27.6%. No outliers were identified. For study fyt9410, RSDr values ranged from 3.9 to 7.9%, and RSDR values ranged from 14.0 to 20.5%. With outliers excluded, RSDr values ranged from 2.5 to 7.9%, and RSDR values ranged from 14.0 to 20.5%.  相似文献   

18.
An interlaboratory study funded by the European Commission, Standards, Measurement and Testing Programme (4th Framework Programme) was performed to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic (LC) method for the determination of ochratoxin A in baby food at a possible future European regulatory limit (0.1 ng/g). The test portion is extracted in a blender with tert-butyl methyl ether (chosen to avoid use of chloroform but shown to give equivalent extraction efficiency) after addition of 0.5 mol/L phosphoric acid-2 mol/L sodium chloride solution. The extract is centrifuged and redissolved in a mixture of phosphate buffered saline solution and methanol. After removal of lypophilic substances with hexane, the extract is applied to an immunoaffinity column containing antibodies specific to ochratoxin A. The column is washed with water to remove the interfering compounds and the purified ochratoxin A is eluted with methanol. The separation and determination of ochratoxin A is performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) with ammonia. Test materials (baby food infant formulae), both spiked and naturally contaminated with ochratoxin A, were sent to 13 laboratories in 8 different European countries. Test portions were spiked at a level of 0.085 ng/g ochratoxin A. The average recovery for the spiked blank baby food was 108%. Based on results for spiked samples (blind pairs at 0.085 ng/g) as well as naturally contaminated samples (blind pairs at levels between 0.05 and 0.22 ng/g) the relative standard deviation for repeatability (RSDr) ranged from 18-36%. The relative standard deviation for reproducibility (RSDR) ranged from 29-63% and HORRAT values of between 0.4 and 0.9 were obtained.  相似文献   

19.
In this study we present a high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method which has been elaborated to analyse steroid hormones, hormone conjugates, oral contraceptives and macrolide antibiotics unchanged in unfiltered influents and effluents of sewage treatment plants (STPs). HPLC separation of the steroid hormones was achieved in 35 min, as well as those of the antibiotics. The analytes were extracted by solid-phase extraction, followed by clean-up using size exclusion chromatography (SEC). For the final quantification HPLC/MS/MS was used. The two ionisation modes, electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI), in HPLC/MS/MS were compared for the analysis of steroid hormones. For quantitative results drastic matrix effects were observed while using ESI. These effects were less pronounced while using APCI. These pitfalls were additionally reduced by clean-up using SEC as well as isotope dilution. Additionally, two multiple reaction monitoring (MRM) transitions per compound were used to prevent false positive results. Recovery experiments with spiked tap water with concentrations varying from 1 to 1000 ng/L gave constant recovery rates: The recovery rates for the hormones and conjugates ranged from 58 to 107%, those of the contraceptives ranged from 83 to 109%. The relative standard deviation was found to be 7 to 24% and the limits of detection were 0.1 to 4.5 ng/L. The recovery rates of the macrolide antibiotics ranged from 76 to 103%, while the relative standard deviation was found to be 7 to 14% and the limits of detection ranged from 0.6 to 1.8 ng/L. The maximum concentrations found in influents of a STP was 470 ng/L for estriol and 1200 ng/L for erythromycin.  相似文献   

20.
An interlaboratory study was performed on behalf of the UK Food Standards Agency to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic (LC) method for the determination of deoxynivalenol in a variety of cereals and cereal products at proposed European regulatory limits. The test portion was extracted with water. The sample extract was filtered a applied to an immunoaffinity column. After being washed with water, the deoxynivalenol was eluted with acetonitrile or methanol. Deoxynivalenol was quantitated by reversed-phase LC with UV determination. Samples of artificially contaminated wheat-flour, rice flour, oat flour, polenta, and wheat based breakfast cereal, naturally contaminated wheat flour, and blank (very low level) samples of each matrix were sent to 13 collaborators in 7 European countries. Participants were asked to spike test portions of all samples at a range of deoxynivalenol concentrations equivalent to 200-2000 ng/g deoxynivalenol. Average recoveries ranged from 78 to 87%. Based on results for 6 artificially contaminated samples (blind duplicates), the relative standard deviation for repeatability (RSDr) ranged from 3.1 to 14.1%, and the relative standard deviation for reproducibility (RSDR) ranged from 11.5 to 26.3%. The method showed acceptable within-laboratory and between-laboratory precision for all 5 matrixes, as evidenced by HorRat values < 1.3.  相似文献   