首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethylcyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS.  相似文献   

2.
The glucuronide conjugates of ketobemidone, norketobemidone and hydroxymethoxyketobemidone were identified in human urine post-intravenous administration of Ketogan Novum. The human urine was extracted on a mixed-mode solid-phase micro-column before analysis with liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and tandem MS (MS/MS). Accurate mass and collision-induced dissociation product ion spectra were used for identification of the glucuronide conjugates. Two different TOF mass spectrometers were used and the accurate mass measurements were performed on three separate days with each instrument. The accuracy of the mass measurements was better than 2.1 ppm for two out of three conjugates and the inter-day relative standard deviation was within +/-0.00049%. The MS/MS fragmentation patterns of the conjugates were in accordance with those of the synthetic aglycones and included peaks originating from the [M + H](+) ion of the respective aglycone.  相似文献   

3.
The potential of electrospray ionization quadrupole-quadrupole-time-of-flight mass spectrometry (ESI-QqTOF-MS) for the characterization of synthetic nucleic acids was evaluated. Oligonucleotides ranging in size from 12 up to 51 nucleotides were analyzed via direct infusion MS as well as via liquid chromatography (LC) online hyphenated to MS. These experiments proved the outstanding mass spectrometric performance of the TOF mass analyzer in regard of accuracy, reproducibility, resolution, and sensitivity. During a 1-min run, the monoisotopic mass of (dT)(24) was measured with a maximum relative mass deviation of 7.64 ppm proving the high mass accuracy of the TOF analyzer. Over a period of 1 h, mean deviations were determined in the range between -3.58 ppm and 3.06 ppm demonstrating the high stability of the applied external calibration. The molecular mass of a 51-mer was measured with a deviation smaller than 3.23 ppm from the theoretical value. The resolution exceeded a value of m/Deltam = 20 000 (m is the measured mass and Deltam the full peak width at half-maximum), which enabled the separation of the isotopic peaks of all investigated oligonucleotides. Because of the outstanding transmission and detection efficiency of the TOF mass analyzer, detection limits in the amol/microl to low fmol/microl range were reached. The usability of LC-ESI-QqTOF-MS for the qualitative and quantitative analysis of synthetic oligonucleotide mixtures was demonstrated.  相似文献   

4.
The combination of mass and normalized elution time (NET) of a peptide identified by liquid chromatography-mass spectrometry (LC-MS) measurements can serve as a unique signature for that peptide. However, the specificity of an LC-MS measurement depends upon the complexity of the proteome (i.e., the number of possible peptides) and the accuracy of the LC-MS measurements. In this work, theoretical tryptic digests of all predicted proteins from the genomes of three organisms of varying complexity were evaluated for specificity. Accuracy of the LC-MS measurement of mass-NET pairs (on a 0 to 1.0 NET scale) was described by bivariate normal sampling distributions centered on the peptide signatures. Measurement accuracy (i.e., mass and NET standard deviations of +/-0.1, 1, 5, and 10 ppm, and +/-0.01 and 0.05, respectively) was varied to evaluate improvements in process quality. The spatially localized confidence score, a conditional probability of peptide uniqueness, formed the basis for the peptide identification. Application of this approach to organisms with comparatively small proteomes, such as Deinococcus radiodurans, shows that modest mass and elution time accuracies are generally adequate for confidently identifying most peptides. For more complex proteomes, more accurate measurements are required. However, the study suggests that the majority of proteins for even the human proteome should be identifiable with reasonable confidence by using LC-MS measurements with mass accuracies within +/-1 ppm and high efficiency separations having elution time measurements within +/-0.01 NET.  相似文献   

5.
Spinetoram is a second-generation member of the spinosyn class, all members of which have been shown to be effective in insect control via a novel mode of action. Spinetoram is a mixture of 3'-O-ethyl-5, 6-dihydro spinosyn J (XDE-175-J) and 3'-O-ethyl spinosyn L (XDE-175-L). In order to establish a determination method for the analysis of spinetoram residues in crops, commercial product (5% suspension concentrate spinetoram) was applied to two leafy vegetables (Garland chrysanthemum and Aster scaber) on different spraying schedules. The analytical method used herein was based on a reversed-phase separation on a C(18) column, isocratic elution and UV detection. The analytes were confirmed via tandem mass spectrometry. The method was linear over a concentration range of 0.05-10 ppm with a correlation coefficient in excess of 0.9998. The recoveries of XDE-175-J and XDE-175-L from the two vegetables ranged between 86.04 and 98.87% at spiking levels of 1 and 5 ppm. The relative standard deviations were no more than 7% for all recovery tests conducted herein. The calculated limits of detection and quantification were 0.01 and 0.03 ppm for both XDE-175-J and XDE-175-L. The levels of residues in two vegetables treated under a fixed schedule in the greenhouse were 6.21-0.55 ppm (maximum residue limit (MRL) = 7 ppm). In sum, this method constitutes an easy and reliable technique for the determination of spinetoram in leafy vegetables.  相似文献   

6.
The use of accurate mass measurement as a confirmation tool is examined on a TOF-MS and compared with confirmation using a triple quadrupole mass spectrometer (QqQ-MS). Confirmation of the identity of a substance using mass-spectrometric detection has been described. However, the use of accurate mass measurement for confirmatory analysis has not been taken into account. In this study, criteria for confirmation with accurate mass are proposed and feasibility is demonstrated. Mass accuracy better than 3 ppm of the quasi-molecular ion and a fragment and their relative ratios determined with LC/TOF-MS are compared to the criteria of two transition ions and their ratio of LC/QqQ-MS. The results show that these criteria can be met for Trenbolone in samples of bovine urine and that single MS accurate mass measurement is comparable to nominal mass MS/MS for confirmation. The increase in popularity and availability of LC/TOF-MS instruments and the ease, of which exact masses can be measured, make it important to formulate criteria for this type of instrumentation. It is shown in this study that accurate mass measurement can be used for confirmatory analysis. However, more experiments need to be conducted to demonstrate the applicability of accurate mass measurement in general for residue analysis.  相似文献   

7.
A dual-ESI-sprayer system was constructed and applied to achieve high accuracy of peptide mass measurement for protein identification by means of peptide mapping. Sample was introduced in one sprayer, and reference in the other, thus making internal calibration possible greatly enhancing the mass accuracy. Several samples were utilized to evaluate the reliability of this dual-ESI-sprayer system. The range of mass errors was 0.16-5.37 ppm. The peptide masses of tryptic digests of myoglobin (horse) were measured by the HPLC/dual-ESI-MS system, with mass deviations ranging from 0.01-7.67 ppm, and about 75% mass deviations below 5 ppm with 40% below 1[?]ppm. These peptide masses were utilized to perform database searching for protein identification, and compared to results obtained by external calibration. This comparison showed that the internal calibration provides a more reliable method of protein identification, with a much smaller number of required peptides for matching, and with less CPU time consumed for database searching.  相似文献   

8.
The transformation products 2-(isopropylcarbamoyl)phenylsulfamic acid and 2-(1-hydroxypropane-2-yl)-1,2-dihydroindazol-3-one could be determined during the photolysis of the herbicide bentazone. Degradation experiments were carried out with different types of water in a natural sunlight simulating system. Besides the anticipated hydroxylated bentazone, the second transformation product was identified by means of exact mass measurement using ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/QqToF MS). Both phototransformation products occurred in all water types tested. The required irradiation time was matrix dependent. 2-(Isopropylcarbamoyl)phenylsulfamic acid was detected in a drainage channel in the Ebro river delta (Catalonia, Spain).  相似文献   

9.
The metabolic profile of BAL4815, an antifungal azole drug, was determined using in vitro rat hepatocyte incubations and subsequent analysis by capillary LC-qTof-MS and MS/MS including accurate mass determination. For the detection of the metabolites, a mixture of the drug and its deuterium-labelled analogue was used for incubations. Metabolic stability of BAL4815 was high in cultured rat hepatocytes. However, several low-abundant metabolites were detected by the use of capillary LC-qTof-MS and manual investigation of the data. The peak intensity of the most abundant metabolite was close to the limit of detection. Except for an apparent oxidation product, the masses of the other detected metabolites could not be assigned to a single and frequently occurring biotransformation. Accurate mass determination and possible elemental compositions suggested that metabolism occurred through a combination of glutathionylation and defluorination. This was verified using accurate mass MS/MS. The use of accurate mass measurements and the derived suggestions for the elemental compositions were essential to elucidate this atypical metabolic pathway. A mass accuracy better than 8 ppm could be achieved for most assigned MS and MS/MS signals with intensities less than 6 cps in the spectra.  相似文献   

10.
A dual electrospray ionization (ESI) source employed with hexapole accumulation and gated trapping provides a novel method of using an internal standard to achieve high mass accuracies in Fourier transform ion cyclotron resonance mass spectrometry. Two ESI emitters are sequentially positioned in front of the heated metal capillary inlet by a solenoid fitted to an XYZ micromanipulator; one emitter contains the analyte(s) of interest and the other an internal standard. A 5 V transistor-transistor logic pulse from the data station controls the solenoid by means of a solid-state relay so that matching of spectral peak intensities (i.e., analyte and internal standard intensities) can be accomplished by adjusting the hexapole accumulation time for each species. Polythymidine, d(pT)18, was used as the internal standard for all studies reported here. The absolute average error for an internally calibrated 15-mer oligonucleotide (theoretical monoisotopic mass = 4548.769 Da) was -1.1 ppm (external calibration: 41 ppm) with a standard deviation of +/-3.0 ppm (external calibration: +/-24 ppm) for a total of 25 spectra obtained at various hexapole accumulation time ratios. Linear least squares regression analysis was carried out and revealed a linear dependence of the magnitudes of the peak height ratios (analyte/internal standard) vs. hexapole accumulation time ratios (analyte/internal standard) which is described by the following equation: y = 0.45 x - 0.02. The fitted line had a %RSD of the slope of 28% with an R2 of 0.93. The applicability of this methodology was extended to a polymerase chain reaction product with a theoretical average molecular mass of 50,849.20 Da. With the internal standard, d(pT)18, an absolute average error of -8.9 ppm (external calibration: 44 ppm) based on five measurements was achieved with a standard deviation of 11 ppm (external calibration: +/-36 ppm), thus illustrating this method's use for characterizing large biomolecules such as those encountered in genomics and proteomics related research.  相似文献   

11.
Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) time-of-flight mass spectrometry (TOFMS) play an essential role in the analysis of biological molecules, not only peptides and proteins, but also DNA and RNA. Tandem mass spectrometry used for sequence analysis has been a major focus of technological developments in mass spectrometry, but accurate mass measurements by high-resolution TOFMS are equally important. This paper describes the role that high mass measurement accuracy can play in DNA composition assignment and discusses the influence of several parameters on mass measurement accuracy in both MALDI and ESI mass spectra. Five oligonucleotides (5-13mers) were used to test the resolving power and mass measurement accuracy obtained with MALDI and ESI instruments with reflectron TOF mass analyzers. The results from the experimental studies and additional theoretical calculations provide a basis to predict the practical utility of high-resolution TOFMS for the analysis of larger oligonucleotides.  相似文献   

12.
大气压离子化技术/飞行时间质谱联用进展   总被引:1,自引:0,他引:1  
综述了大气压离子化技术/飞行时间质谱联用技术及其应用的进展  相似文献   

13.
Arginine (ARG) is a substrate for endogenous nitric oxide (NO) production whereas its metabolite, asymmetric dimethylarginine (ADMA), acts as an inhibitor. Sufficient NO production is essential for cardiovascular key functions, thus elevated concentration levels of ADMA are related to a range of cardiovascular diseases. Owing to the lack of reliable methods for the measurement of ARG and ADMA in human plasma, concentration values determined with these methods can differ considerably. We present here a simple and very robust liquid chromatographic/mass spectrometric method for the determination of ARG and ADMA utilizing isotope-labeled internal standards. Sample preparation requires only protein precipitation; the analytes were derivatized with o-phthalaldehyde-mercaptoethanol and separated on a reversed-phase C(18) column with gradient elution. The analytes were detected with an electrospray ionization ion trap instrument working in the full-scan single mass spectrometry mode. Concentration values obtained with this method for healthy controls were ARG = 63.9 +/- 23.9 microM and ADMA = 0.355 +/- 0.066 microM, with a normal range for ADMA from 0.225 to 0.485 microM. The corresponding values for end-stage chronic renal failure patients are ARG = 48.1 +/- 18.5 microM, p < 0.01 and ADMA = 0.673 +/- 0.134 M, p < 0.001.  相似文献   

14.
Jin Y  Manabe T 《Electrophoresis》2005,26(6):1019-1028
A simple and fast method of protein extraction from Coomassie Brilliant Blue (CBB)-stained polyacrylamide gels suited for molecular mass measurement of proteins by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS) is reported. Proteins in CBB-stained gel pieces were extracted by a 10-min soaking in 0.1 M NaOH at 25 degrees C. The recovery of this one-step extraction method was 34-73% for proteins <67 kDa. CBB adduction to proteins during mass spectrometric analysis was avoided by a destaining step before the alkaline extraction. The molecular mass values of the extracted proteins coincided with those of purified proteins within +/-0.01-0.10% deviation for all the proteins <36 kDa. Because of the high extraction recovery, mass measurement was possible for the proteins extracted from CBB-stained gels with loaded protein quantities as little as 34 ng for cytochrome c, alpha-lactalbumin, myoglobin, beta-lactoglobulin, trypsinogen, and carbonic anhydrase (12.4-29.0 kDa), 340 ng for glyceraldehyde-3-phosphate dehydrogenase (35.6 kDa) and albumin (66.3 kDa). This method provides a highly efficient approach to utilize CBB-stained one- or two-dimensional gels for whole protein analysis using MALDI-TOF-MS.  相似文献   

15.
We present a novel method for the purity assessment of peptide standards which is applicable to any water soluble peptide. The method is based on the online 13C isotope dilution approach in which the peptide is separated from its related impurities by liquid chromatography (LC) and the eluent is mixed post-column with a continuous flow of 13C-enriched sodium bicarbonate. An online oxidation step using sodium persulfate in acidic media at 99 °C provides quantitative oxidation to 12CO2 and 13CO2 respectively which is extracted to a gaseous phase with the help of a gas permeable membrane. The measurement of the isotope ratio 44/45 in the mass spectrometer allows the construction of the mass flow chromatogram. As the only species that is finally measured in the mass spectrometer is CO2, the peptide content in the standard can be quantified, on the base of its carbon content, using a generic primary standard such as potassium hydrogen phthalate. The approach was validated by the analysis of a reference material (NIST 8327), and applied to the quantification of two commercial synthetic peptide standards. In that case, the results obtained were compared with those obtained using alternative methods, such as amino acid analysis and ICP-MS. The results obtained proved the value of the method for the fast, accurate and precise mass purity assignment of synthetic peptide standards.  相似文献   

16.
Electrospray ionization (ESI) of peptides and proteins produces a series of multiply charged ions with a mass/charge (m/z) ratio between 500 and 2000. The resulting mass spectra are crowded by these multiple charge values for each molecular mass and an isotopic cluster for each nominal m/z value. Here, we report a new algorithm simultaneously to deconvolute and deisotope ESI mass spectra from complex peptide samples based on their mass-dependent isotopic mean pattern. All signals corresponding to one peptide in the sample were reduced to one singly charged monoisotopic peak, thereby significantly reducing the number of signals, increasing the signal intensity and improving the signal-to-noise ratio. The mass list produced could be used directly for database searching. The developed algorithm also simplified interpretation of fragment ion spectra of multiply charged parent ions.  相似文献   

17.
The array of analytes that can be measured by MADLI MS has created an equally vast range of calibration mixtures. The inherent problem with this is that acquiring all of them at commercial rates can be prohibitively expensive. With this in mind, we have created a low‐cost alternative to the most commonly used peptide calibrants. We were able to achieve an overall 78 ppm mass accuracy across a mass range of 900 to 2500 Da which was comparable to the mass accuracy achievable with commercial peptide mixes and hence has become a viable alternative.  相似文献   

18.
High mass measurement accuracy (MMA) is demonstrated for intact proteins and subsequent collision-induced dissociation product ions using internal calibration. Internal calibration was accomplished using a dual electrospray ionization source coupled with a hybrid quadrupole Fourier transform ion cyclotron resonance (Q-FT-ICR) mass spectrometer. Initially, analyte ions generated via the first electrospray (ESI) emitter are isolated and dissociated in the external quadrupole. This event is followed by a simultaneous switch to the calibrant ion ESI emitter and a disablement of the isolation and activation of the external quadrupole such that a broad m/z range of calibrant ions are accumulated before injecting the analyte/calibrant ion mixture into the ICR cell. Two different internal calibrant solutions were utilized in these studies to evaluate this approach for the top-down characterization of melittin and ubiquitin. While external calibration of protein fragments resulted in absolute MMA greater than 16 ppm, internal standardization significantly improved upon the MMA of both the intact proteins and their products ions which ranged from -2.0 ppm to 1.1 ppm, with an average of -0.9 ppm. This method requires limited modification to ESI-FT-ICR mass spectrometers and is applicable for both positive and negative ionization modes.  相似文献   

19.
The last 2 years multi-compound methods are gaining ground as screening methods. In this study a high-resolution liquid chromatography combined with time-of-flight mass spectrometry (HRLC–ToF-MS) is tested for the screening of about 100 veterinary drugs in three matrices, meat, fish and egg. While the results are satisfactory for 70–90% of the veterinary drugs, a more efficient sample preparation or extract purification is required for quantitative analysis of all analytes in more difficult matrices like egg. The average mass measurement error of the ToF-MS for the veterinary drugs spiked at concentrations ranging from 4 to 400 μg/kg, is 3.0 ppm (median 2.5 ppm) with little difference between the three matrices, but slightly decreases with increasing concentration. The SigmaFit value, a new feature for isotope pattern matching, also decreases with increasing concentration and, in addition, shows an increase with increasing matrix complexity. While the average SigmaFit value is 0.04, the median is 0.01 indicating some high individual deviations. As with the mass measurement error, the highest deviations are found in those regions of the chromatogram where most compounds elute from the column, be it analytes or matrix compounds. The median repeatability of the method ranges from 8% to 15%, decreasing with increasing concentration, while the median reproducibility ranges from 15% to 20% with little difference between matrices and concentrations. The median accuracy is in between 70% and 100% with a few compounds showing higher values due to matrix interference. The squared regression coefficient is >0.99 for 92% of the compounds showing a good overall linearity for most compounds. The detection capability, CCβ, is within 2 times the associated validation level for >90% of the compounds studied. By changing a few conditions in the analyses protocol and analysing a number of blank samples, it was determined that the method is robust as well as specific. Finally, an alternative validation strategy is proposed and tested for screening methods. While the results calculated for repeatability, within-lab reproducibility and CCβ show a good comparison for the matrices meat and fish, and a reasonable comparison for the matrix egg, only 27 analyses are required to obtain these results versus 63 analysis in the traditional, 2002/657/EC, approach. This alternative is suggested as a cost-effective validation procedure for screening methods.  相似文献   

20.
Xu C  Suo R  Zhang F  Chu X  Ding F  Ling Y  Yang M  Sun L 《色谱》2012,30(5):457-462
建立了测定动物饲料中三唑仑、艾司唑仑、硝西泮、地西泮、异丙嗪、氯氮平、唑吡坦、甲硫哒嗪、氯丙嗪和咪达唑仑10种违禁精神药物的超高效液相色谱-四极杆飞行时间质谱(UPLC-Q-TOF-MS)方法。样品经混合溶剂甲醇-0.1 mol/L HCl(9:1, v/v)振荡提取,再用MCX固相萃取柱净化处理后,采用UPLC-Q-TOF-MS分析检测。10种化合物在5~100 μg/L范围内均呈良好的线性关系,线性相关系数均大于0.99。本方法的硝西泮、唑吡坦和甲硫哒嗪的定量限(LOQ,以信噪比为10计)为8 μg/kg,三唑仑、艾司唑仑、地西泮、异丙嗪、氯丙嗪和咪达唑仑为10 μg/kg,氯氮平为20 μg/kg。3个添加水平(LOQ、2LOQ、4LOQ)的回收率试验结果表明,10种化合物的回收率在60.6%~108.5%范围内,相对标准偏差均小于10%。本方法可用于动物饲料中违禁精神药物的准确测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号