首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.

This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC–FD), liquid chromatography–mass spectrometry (LC–MS) and liquid chromatography-tandem mass spectrometry (LC–MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean–up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC–FD, from 0.3 to 1.8 using LC–MS and from 0.2 to 0.3 using LC–MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).

  相似文献   

3.
Liquid chromatography–tandem mass spectrometry (LC–MS/MS) has been increasingly used in routine clinical laboratories during the last two decades. The high specificity, sensitivity, and multi-analyte potential make it an ideal alternative to immunoassays or conventional high-performance liquid chromatography (HPLC). It also provides higher throughput than gas chromatography–mass spectrometry (GC–MS). LC–MS/MS also offers higher flexibility than immunoassays because LC–MS/MS assays are typically developed in-house. In addition, abundant information can be obtained from a single LC–MS/MS run which can produce a large amount of quantitative or qualitative data. In this review, typical LC–MS/MS clinical applications are presented, personal experiences are shared, and strengths and weakness are discussed. It is foreseeable that LC–MS/MS will become a key instrument in routine clinical laboratories.  相似文献   

4.
This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC–FD), liquid chromatography–mass spectrometry (LC–MS) and liquid chromatography-tandem mass spectrometry (LC–MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean–up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g?1 using LC–FD, from 0.3 to 1.8 using LC–MS and from 0.2 to 0.3 using LC–MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).  相似文献   

5.
This paper presents the multiresidue determination of the series of quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid and flumequine) in bovine and porcine plasma using capillary electrophoresis and liquid chromatography with ultraviolet detection (CE‐UV, LC‐UV), liquid chromatography–mass spectrometry and –tandem mass spectrometry (LC‐MS, LC‐MS/MS) methods. These procedures involve a sample preparation by solid‐phase extraction for clean‐up and preconcentration of the analytes before their injection into the separation system. All methods give satisfactory results in terms of linearity, precision, accuracy and limits of quantification. The suitability of the methods to determine quinolones was evaluated by determining the concentration of enrofloxacin and ciprofloxacin in real samples from pig plasma and cow plasma. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
7.
This article reviews research on the qualitative and quantitative analysis by high-performance column liquid chromatography/mass spectrometry (LC/MS) and LC/tandem mass spectrometry (LC/MS/MS) of botanical drugs, drug substances or preparations, and finished botanical products. In addition, LC/MS and LC/MS/MS techniques and commercial instruments are described and compared briefly, and prospects for future use of these methods for the analysis of botanicals are suggested. Some applications of direct MS without LC are also described.  相似文献   

8.
A rapid, precise, and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method has been developed for the characterization of stressed degradation products of mirabegron. It is used in the treatment of overactive bladder and administered to treat urinary symptoms such as urgency or frequency and incontinence. It also works by relaxing the muscles around bladder.

Mirabegron was subjected to hydrolysis (acidic, alkaline, and neutral) and peroxidation, as per ICH-specified conditions. The drug showed degradation under stress conditions. However, it was stable to neutral conditions. A total of seven degradation products were observed and the chromatographic separation of the drug and its degradation products was achieved on X-TerraRP-8 (250 mm × 4.6 mm, i.d., 5 µm) column using 0.01 M ammonium acetate as mobile phase-A and 60:40 ratio of acetonitrile (ACN):water as mobile phase-B. The degradation products were characterized by LC–MS/MS and its fragmentation pathways were proposed. Probable possible structures were drawn based on parent and daughter molecular ions. One peroxide degradant impurity was isolated using preparative LC and characterized using liquid chromatography–mass spectrometry and NMR data.  相似文献   

9.
Since the wide adoption of liquid chromatography/tandem mass spectrometry (LC/MS/MS), the ion suppression/enhancement phenomenon is the latest barrier to high-throughput analysis. This consequence of a nonoptimized analytical method can lead to adverse effects during quantitation (i.e. poor accuracy and precision). Previous papers have reported that ion suppression is a direct result of endogenous material present in biological samples. However, in the case of a solid-phase liquid chromatography/tandem mass spectrometry (SPE/LC/MS/MS) system, the measured result is the combination of several operating conditions and parameters. Little has been done to effectively monitor and/or choose optimized conditions for the complete sequence of extraction, clean up, separation and analysis. This paper describes a simple setup for quantification of ion suppression/enhancement. Several mobile phase additives, ion-pairing agents and SPE extracts were measured and compared against a standard reference. The results demonstrated that a clean up of plasma extracts based on ion exchange leads to minimal ion suppression/enhancement for the compounds that were investigated.  相似文献   

10.
A ‘suspect screening analysis’ method for grape metabolomics by ultra‐high performance‐liquid chromatography (UHPLC) and high‐resolution quadrupole‐time of flight (QTOF) mass spectrometry was recently developed. This method was applied to study grape monoterpene glycosides, the main grape aroma precursors. Since standard compounds were not available, they were tentatively identified by overlapping various analytical approaches, in agreement with the indications recommended in mass spectrometry (MS)‐based metabolomics. Accurate mass and isotopic pattern, MS/MS fragmentation, correlation between fragments observed and putative structures and between liquid chromatography coupled with mass spectrometry (LC/MS) and gas chromatography/mass spectrometry signals were studied. Seventeen monoterpene glycosides were identified without performing the hydrolytic artifacts commonly used to study these compounds which may affect sample profile. This is the first time that a detailed study of these aroma precursors has been carried out by direct LC/MS analysis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
The process of metabolite identification is essential to the drug discovery and development process; this is usually achieved by liquid chromatography/tandem mass spectrometry (LC/MS/MS) or a combination of liquid chromatography/mass spectrometry (LC/MS) and nuclear magnetic resonance (NMR) spectroscopy. Metabolite identification is, however, a time-consuming process requiring an experienced skilled scientist. Multivariate statistical analysis has been used in the field of metabonomics to elucidate differences in endogenous biological profiling due to a toxic effect or a disease state. In this paper we show how a combination of liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) and multivariate statistical analysis can be used to detect drug metabolites in a biological fluid with no prior knowledge of the compound administered.  相似文献   

12.
We report a high-throughput liquid chromatography/mass spectrometry (LC/MS) protocol for analyzing large combinatorial libraries using an eight-channel parallel LC/UV/MS (MUX-LCT) system. System configuration, linear response range in UV absorbance, LC column selection, and flow rate were optimized for 24 h/7 day unattended operations. Combinatorial libraries were analyzed on this system at a rate of 3200 compounds per day for a 3.5 min cycle time per injection. This parallel system is compared with a single-channel system in terms of performance and operation.  相似文献   

13.
The preparation of protein substrates requires that a large number of chromatographic fractions be analyzed for the presence of reactants, products and by-products. Analyses using linear matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) or single column liquid chromatography/mass spectrometry (LC/MS) have been inadequate because of mass resolution or throughput. Therefore, a high-throughput method employing an eight-channel parallel reverse-phase LC/MS system was developed. This system is capable of screening fractions from preparative ion-exchange chromatography with the required mass accuracy and throughput so that the protein purification process can be monitored in a relatively short period of time. As an example, the purification and analysis of an acylated protein with a molecular weight of 8.9 kDa is described and the detection of a contaminating by-product that differs in size by less than 20 Da is demonstrated. Using the current instrumentation and approach, it is practical to analyze 50 protein-containing fractions from column chromatography in less than 1 hour using parallel LC/MS.  相似文献   

14.
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.  相似文献   

15.
In recent years, liquid chromatography with tandem mass spectrometry (LC–MS/MS) has become a fundamental technology in clinical practice. In Japan, the LC–MS/MS system is used in many large hospitals. It has become popular among pharmacists and laboratory technicians. LC–MS/MS has some advantages in terms of accuracy, speed, and comprehensiveness compared to conventional automated chemical testing equipment. However, LC–MS/MS is by no means a universal method, and it is necessary to understand its characteristics before using it. In the field of therapeutic drug monitoring (TDM), there is an issue with linearity in comprehensive measurement; however, ion-abundance adjustment methods, such as in-source collision-induced dissociation, have been proposed as a solution to this problem. The development of a biomarker analysis includes search, identification, and quantification, and it is necessary to select an appropriate mass spectrometric method for each step. In this paper, we review cutting-edge technologies that can expand the performance of LC–MS/MS in the clinical field and consider current issues and future prospects.  相似文献   

16.
A liquid chromatography/mass spectrometry (LC/MS) method for the analysis of complex mixtures of nucleoside mono-, di- and triphosphates has been developed. A short capillary column (35mm x 0.3mm i.d.) was operated under ion-pair high-performance liquid chromatography conditions and hyphenated to (negative) electrospray (tandem) mass spectrometry. As such, the separation of 12 nucleotides was performed by a binary gradient elution using CH(3)OH/H(2)O and N,N-dimethylhexylamine (N,N-DMHA) as ion-pairing agent. The influence of different N,N-DMHA concentrations on the chromatographic and mass spectrometric performance was evaluated to achieve optimal LC/MS conditions. In addition it was demonstrated that a controlled admission of ammonium dihydrogen phosphate (NH(4)H(2)PO(4)) improved both chromatographic performance and mass spectrometric detection. Because the system was hyphenated to an orthogonal designed electrospray interface (Z-spraytrade mark), long acquisition times were possible without loss of sensitivity.  相似文献   

17.
Today, it is necessary to identify relevant compounds appearing in discovery and development of new drug substances in the pharmaceutical industry. For that purpose, the measurement of accurate molecular mass and empirical formula calculation is very important for structure elucidation in addition to other available analytical methods. In this work, the identification and confirmation of degradation products in a finished dosage form of the antibiotic drug amoxicillin obtained under stress conditions will be demonstrated. Structure elucidation is performed utilizing liquid chromatography (LC) ion trap MS/MS and MS3 together with accurate mass measurement of the molecular ions and of the collision induced dissociation (CID) fragments by liquid chromatography electro spray ionization time-of-flight mass spectrometry (LC/ESI-TOF).  相似文献   

18.
Qualitative and quantitative analyses of phenolic compounds are of interest for both medicinal and food plants. In the present work, the phenolic fraction from Yucca schidigera, a plant bearing the GRAS (Generally Recognized as Safe) label approved by the US Food and Drug Administration, was studied. Crude extracts of Y. schidigera bark were investigated by liquid chromatography/UV spectrophotometry with diode-array detection, liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS), in order to develop and optimize simple and rapid techniques to determine both stilbenes and yuccaols for the purposes of quality control of collected material. With optimal LC and MS conditions, stilbenes and yuccaols were quantified with all the proposed methods and the results were compared. Sensitivity was evaluated and the results indicated that MS/MS detection in the multiple reaction monitoring mode is easily applicable to this plant and allows the rapid and direct identification and quantification of these peculiar compounds in crude plant extracts.  相似文献   

19.
Quantitative analysis of liquid chromatography (LC)-mass spectrometry (MS) and tandem mass spectrometry (MS/MS) data is essential to many proteomics studies. We have developed MASIC(2) to accurately measure peptide abundances and LC elution times in LC-MS/MS analyses. This software program uses an efficient processing algorithm to quickly generate mass specific selected ion chromatograms from a dataset and provides an interactive browser that allows users to examine individual chromatograms with a variety of options.  相似文献   

20.
In this study, a sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the quantification of demethylzeylasteral in rat plasma. Electrospray ionization was operated in the negative ion mode while demethylzeylasteral and oleanolic acid (internal standard) were measured by selected reaction monitoring (demethylzeylasteral: m/z 479.2 → 436.0; oleanolic acid: m/z 454.9 → 407.2). This LC–MS/MS method had good selectivity, sensitivity, accuracy and precision. The pharmacokinetic profiles of demethylzeylasteral were subsequently examined in Wistar rats after oral or intravenous administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号