首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 543 毫秒
1.
A sensitive, rapid and selective ultra‐performance liquid chromatography–tandem mass spectrometric (UPLC‐MS/MS) method was developed for the determination and pharmacokinetic study of domperidone in human plasma. Diphenhydramine was used as the internal standard. Plasma sample pretreatment involved a one‐step liquid–liquid extraction with a mixture of diethyl ether–dichloromethane (3:2, v/v). The analysis was carried out on an Acquity UPLCTM BEH C18 column. The mobile phase consisted of methanol–water containing 10 mmol/L ammonium acetate and 0.5% (v/v) formic acid (60:40, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionizationsource with positive mode. Each plasma sample was chromatographed within 2.1 min. The standard curves for domperidone were linear (r2 ≥ 0.99) over the concentration range of 0.030–31.5 ng/mL with a lower limit of quantification of 0.030 ng/mL. The intra‐ and inter‐day precision (relative standard deviation) values were not higher than 13% and accuracy (relative error) was from ?7.6 to 1.2% at three quality control levels. The method herein described was superior to previous methods and was successfully applied to the pharmacokinetic study of domperidone in healthy Chinese volunteers after oral administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
A rapid, selective and sensitive high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) method was developed to determine meloxicam in beagle dog plasma. Sample pretreatment involved a one‐step protein precipitation with methanol of 0.1 mL plasma. Analysis was performed on a Venusil ASB‐C18 column with mobile phase consisting of methanol–water (containing 0.1% formic acid) (75:25, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization source. Each plasma sample was chromatographed within 4.1 min. The linear calibration curves for meloxicam was obtained in the concentration range of 10.3–4.12 × 103 ng/mL (r ≥ 0.99). The intra‐ and inter‐day precisions (relative standard deviation) were ≤ 15%, and accuracy (relative error) was within ±7.3%. The method herein described was fully validated and successfully applied to the pharmacokinetic study of meloxicam tablets in beagle dog.  相似文献   

3.
A rapid, sensitive and selective liquid chromatography–tandem mass spectrometry method for the detection of tandospirone (TDS) and its active metabolite 1‐[2‐pyrimidyl]‐piperazine (1‐PP) in Sprague–Dawley rat plasma is described. It was employed in a pharmacokinetic study. These analytes and the internal standards were extracted from plasma using protein precipitation with acetonitrile, then separated on a CAPCELL PAK ADME C18 column using a mobile phase of acetonitrile and 5 mm ammonium formate acidified with formic acid (0.1%, v/v) at a total flow rate of 0.4 mL/min. The detection was performed with a tandem mass spectrometer equipped with an electrospray ionization source. The method was validated to quantify the concentration ranges of 1.000–500.0 ng/mL for TDS and 10.00–500.0 ng/mL for 1‐PP. Total time for each chromatograph was 3.0 min. The intra‐day precision was between 1.42 and 6.69% and the accuracy ranged from 95.74 to 110.18% for all analytes. Inter‐day precision and accuracy ranged from 2.47 to 6.02% and from 98.37 to 105.62%, respectively. The lower limits of quantification were 1.000 ng/mL for TDS and 10.00 ng/mL for 1‐PP. This method provided a fast, sensitive and selective analytical tool for quantification of tandospirone and its metabolite 1‐PP in plasma necessary for the pharmacokinetic investigation.  相似文献   

4.
A fast, sensitive and reliable ultra performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed and validated for simultaneous quantitation and pharmacokinetic study of five tanshinones (tanshinone I, tanshinone IIA, tanshinone IIB, dihydrotanshinone I, cryptotanshinone), the bio‐active ingredients of Huo Luo Xiao Ling Dan (HLXLD) in rat plasma. After liquid–liquid extraction, chromatographic separation was accomplished on a Shim‐pack XR‐ODS column (75 × 3.0 mm, 2.2 µm particles) and eluted with a mobile phase consisting of acetonitrile–0.05% formic acid aqueous solution (80:20, v/v) at a flow rate of 0.4 mL/min, and the total run time was 7.0 min. The detection was performed on a triple quadrupole tandem mass spectrometry equipped with an electrospray ionization source in positive ionization and multiple reaction monitoring mode. The lower limits of quantification were 0.050–0.400 ng/mL for all the analytes. Linearity, precision and accuracy, the mean extraction recoveries and matrix effects all satisfied criteria for acceptance. This validated method was successfully applied to a comparative pharmacokinetic study of five bio‐active components in rat plasma after oral administration of HLXLD or Salvia miltiorrhiza extract in normal and arthritic rats. The results showed that there were different pharmacokinetic characteristics among different groups. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

5.
A highly sensitive and rapid bioanalytical method has been developed and validated for the estimation of indomethacin in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of indomethacin and phenacetin (internal standard, IS) from rat plasma with acetonitrile. Chromatographic separation was achieved with 0.2% formic acid–acetonitrile (25:75, v/v) at a flow rate of 0.60 mL/min on an Atlantis dC18 column with a total run time 3.0 min. The MS/MS ion transitions monitored were 357.7 → 139.1 for indomethacin and 180.20 → 110.10 for IS. Method validation and pharmacokinetic study plasma analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.51 ng/mL and the linearity was observed from 0.51 to 25.5 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.00–10.2 and 5.88–9.80%, respectively. This novel method has been applied to an oral pharmacokinetic study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of salviaflaside and rosmarinic acid in rat plasma. Sample preparation was carried out through liquid–liquid extraction with ethyl acetate using curculigoside as internal standard (IS). The analytes were determined by selected reaction monitoring operated in the positive ESI mode. Chromatographic separation was performed on an Agilent Eclipse Plus C18 column (100 × 4.6 mm, 1.8 μm) with a mobile phase consisting of methanol–water–formic acid (50:50:0.1, v/v/v) at a flow rate of 0.3 mL/min. The run time was 1.9 min per sample and the injection volume was 5 μL. The method had an LLOQ of 1.6 ng/mL for salviaflaside and 0.94 ng/mL for rosmarinic acid in plasma. The linear calibration curves were fitted over the range of 1.6–320 ng/mL for salviaflaside and 0.94–188 ng/mL for rosmarinic acid in plasma with correlation coefficients (r2) >0.99. Intra‐ and inter‐day precisions (relative standard deviation) were < 13.5%, and accuracies (relative error) were between −8.6% and 14.5% for all quality control samples. The method was validated and applied to the pharmacokinetics of salviaflaside and rosmarinic acid in plasma after oral administration of Prunella vulgaris extract to rats.  相似文献   

7.
A sensitive and reliable bioanalytical method was established for quantitati\ve and pharmacokinetic investigation of nine ginsenosides and seven bufadienolides in rat plasma after the oral administration of Shexiang Baoxin Pill by liquid chromatography–electrospray ionization tandem mass spectrometry, using tinidazole and digoxin as internal standards (ISTDs). All of the analytes and ISTDs obtained satisfactory recoveries by solid‐phase extraction using an Oasis HLB μElution Plate, which was eluted with methanol and ethyl acetate successively, and chromatographic separation was achieved on a Shim‐pack XR‐ODSIIcolumn (75 × 2.0 mm, 2.2 μm) with gradient elution using a mixture of acetonitrile–0.1% formic acid solution (v /v) as the mobile phase at a flow rate of 0.3 mL/min. Detection was carried out by a triple‐quadrupole tandem mass spectrometry with positive/negative ion switching multiple reaction monitoring mode. All analytes showed good linearity over a wide concentration range (r 2 > 0.99). The lower limit of quantification was in the range 0.625–12.5 ng/mL for bufadienolides and 2–5.5 ng/mL for ginsenosides, and the mean recoveries of all analytes were in the range 78.29–99.35%. The intra‐ and inter‐day precisions (RSD) were in the range 0.08–12.38% with the accuracies between 86.09 and 99.40%. The validated method was then successfully applied to pharmacokinetic study of the above 16 compounds in rat plasma. Pharmacokinetic results indicated that the developed extraction and analytical method could be employed as a rapid, effective technique for pharmacokinetic study of multiple components, especially various polarity that are difficult to extract simultaneously.  相似文献   

8.
A rapid, selective and sensitive ultra‐high‐performance liquid chromatography–tandem mass spectrometry method was developed to simultaneously determine oxybutynin and its active metabolite N‐desethyl oxybutynin in rat plasma. A 0.1 mL sample of plasma was extracted with n‐hexane. Chromatographic separation was performed on a UPLC BEH C18 column (2.1 × 100 mm i.d.,1.7 μm) with mobile phase of methanol–water (containing 2 mmol/L ammonium acetate and 0.1% formic acid; 90:10, v/v). The detection was performed in positive selected reaction monitoring mode. Each plasma sample was chromatographed within 3 min. The linear calibration curves were obtained in the concentration range of 0.0944–189 ng/mL (r ≥ 0.99) for oxybutynin and 0.226–18.0 ng/mL (r ≥ 0.99) for N‐desethyl oxybutynin. The intra‐ and inter‐day precision (relative standard deviation) values were not more than 14% and the accuracy (relative error) was within ±7.6%. The method described was superior to previous methods for the quantitation of oxybutynin with three product ions and was successfully applied to a pharmacokinetic study of oxybutynin and its active metabolite N‐desethyl oxybutynin in rat plasma after transdermal administration.  相似文献   

9.
Styraxlignolide A is a pharmacologically active ingredient isolated from Styrax japonica Sieb. et Zucc. A rapid, selective, and sensitive liquid chromatographic method with electrospray ionization tandem mass spectrometry was developed for use in the quantification of styraxlignolide A in rat plasma. Styraxlignolide A was extracted from rat plasma using ethyl acetate at neutral pH. The analytes were separated on an Atlantis dC18 column using a mixture of methanol and ammonium formate (10 mM, pH 3.0) (70:30, v/v) and detected by tandem mass spectrometry in multiple reaction monitoring mode. The standard curve was linear (r2=0.9978) over the concentration range of 100?10000 ng/mL. The lower limit of quantification was 100 ng/mL using 50 μL of plasma sample. The coefficient of variation and relative error for intra‐ and inter‐assays at four QC levels were 1.6–8.3% and from ?12.0 to ?1.7%, respectively. The present method was applied successfully to the pharmacokinetic study of styraxlignolide A after intravenous administration of styraxlignolide A at a dose of 10 mg/kg in male Sprague–Dawley rats.  相似文献   

10.
A sensitive liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method was developed and validated for the simultaneous determination of ramelteon and its active metabolite M‐II in human plasma. After extraction from 200 μL of plasma by protein precipitation, the analytes and internal standard (IS) diazepam were separated on a Hedera ODS‐2 (5 μm, 150 × 2.1 mm) column with a mobile phase consisted of methanol–0.1% formic acid in 10 mm ammonium acetate solution (85:15, v/v) delivered at a flow rate of 0.5 mL/min. Mass spectrometric detection was operated in positive multiple reaction monitoring mode. The calibration curves were linear over the concentration range of 0.0500–30.0 ng/mL for ramelteon and 1.00–250 ng/mL for M‐II, respectively. This method was successfully applied to a clinical pharmacokinetic study in healthy Chinese volunteers after a single oral administration of ramelteon. The maximum plasma concentration (Cmax), the time to the Cmax and the elimination half‐life for ramelteon were 4.50 ± 4.64ng/mL, 0.8 ± 0.4h and 1.0 ± 0.9 h, respectively, and for M‐II were 136 ± 36 ng/mL, 1.1 ± 0.5 h, 2.1 ± 0.4 h, respectively.  相似文献   

11.
A hydrophilic interaction chromatography-electrospray ionization tandem mass spectrometric method was developed for determination of anastrozole in human plasma. Anastrozole and irbesartan (internal standard) were extracted from human plasma with a mixture of dichloromethane and methyl tert-butyl ether (30:70, v/v). Analysis of the analytes was performed on a Luna HILIC column with the mobile phase of acetonitrile-10 m m ammonium formate (95:5, v/v) and detected by electrospray ionization tandem mass spectrometry in the selected reaction monitoring mode. The standard curve was linear (r(2) = 0.9992) over the concentration range of 0.10-50.0 ng/mL using 200 μL of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.2-10.0% and -7.2-3.2%, respectively. The present method was applied successfully to the pharmacokinetic study of anastrozole after oral administration of 1 mg anastrozole tablet to healthy male volunteers.  相似文献   

12.
In this study, a new LC‐ESI‐MS/MS‐based method was validated for the quantitation of hemslecin A in rhesus monkey plasma using otophylloside A as internal standard (IS). Hemslecin A and the IS were extracted from rhesus monkey plasma using liquid–liquid extraction as the sample clean‐up procedure, and were subjected to chromatography on a Phenomenex Luna CN column (150 × 2.0 mm, 3.0 µm) with the mobile phase consisting of methanol and 0.02 mol/mL ammonium acetate (55:45, v/v) at a flow rate of 0.2 mL/min. Detection was performed on an Agilent G6410B tandem mass spectrometer by positive ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 580.5 [M + NH4]+ → 503.4 and m/z 518.2 [M + NH4]+ → 345.0 for hemslecin A and IS, respectively. The assay was linear over the concentration range of 0.5–200 ng/mL and was successfully applied to a pharmacokinetic study in rhesus monkeys. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
This study aims to develop and validate a simple and sensitive liquid chromatography with tandem mass spectrometry (LC–MS/MS) method for investigating the pharmacokinetic characteristics of bavachalcone. Liquid–liquid extraction was used to prepare plasma sample. Chromatographic separation of bavachalcone and IS was achieved using a Venusil ASB C18 (2.1 × 50 mm, 5 μm) column with a mobile phase of methanol (A)–water (B) (70:30, v /v). The detection and quantification of analytes was performed in selected‐reaction monitoring mode using precursor → product ion combinations of m/z 323.1 → 203.2 for bavachalcone, and m/z 373.0 → 179.0 for IS. Linear calibration plots were achieved in the range of 1–1000 ng/mL for bavachalcone (r 2 > 0.99) in rat plasma. The recovery of bavachalcone ranged from 84.1 to 87.0%. The method was precise, accurate and reliable. It was fully validated and successfully applied to pharmacokinetic study of bavachalcone.  相似文献   

14.
A sensitive, fast and specific method for the quantitation of pinocembrin in human plasma based on high‐performance liquid chromatography–tandem mass spectrometry (LC/MS/MS) was developed and validated. Clonazepam was used as the internal standard (IS). After solid‐phase extraction of 500 μL plasma, pinocembrin and the IS were separated on a Luna C8 column using the mobile phase composed of acetonitrile–0.3 mm ammonium acetate solution (65:35, v/v) at a flow rate of 0.25 mL/min in isocratic mode. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via an electrospray ionization source in negative mode by AB SCIEX Qtrap 5500. The assay was linear from 1 to 400 ng/mL, with within‐ and between‐run accuracy (relative error) from ?1.82 to 0.54%, and within‐ and between‐run precision (CV) below 5.25%. The recovery was above 88% for the analyte at 1, 50 and 300 ng/mL. This analytical method was successful for the determination of pinocembrin in human plasma and applied to a pharmacokinetic study of pinocembrin injection in healthy volunteers after intravenous drip administration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
A simple, rapid and sensitive liquid chromatography–tandem mass spectrometric (LC‐MS/MS) assay method has been developed and validated for simultaneous quantification of sitagliptin and simvastatin in human plasma. Carbamazepine was used as an internal standard (IS). The analytes and IS were extracted from the human plasma by liquid–liquid extraction technique. The reconstituted samples were chromatographed on an Alltima HP C18 column using an isocratic solvent mixture [acetonitrile–5 mm ammonium acetate (pH 4.5), 85:15 (v/v)] at a flow rate of 1.0 mL/min. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curves obtained were linear (r2 ≥ 0.99) over the concentration range of 0.10–501 and 0.05–105 ng/mL for sitagliptin and simvastatin, respectively. The results of the intra‐ and inter‐day precision and accuracy studies were well within the acceptable limits. Both the analytes were found to be stable in a battery of stability studies. The method is precise and sensitive enough for its intended purpose. A run time of 3.0 min for each sample made it possible to analyze more than 300 plasma samples per day. The developed assay was successfully applied to a pharmacokinetic study in human volunteers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A highly sensitive, rapid assay method has been developed and validated for the estimation of S‐citalopram (S‐CPM) in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of S‐CPM and phenacetin (internal standard, IS) from rat plasma with t‐butyl methyl ether. Chromatographic separation was operated with 0.2% formic acid:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Symmetry Shield RP18 column with a total run time of 3.0 min. The MS/MS ion transitions monitored were 325.26 → 109.10 for S‐CPM and 180.10 → 110.10 for IS. Method validation and pre‐clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.5 ng/mL and the linearity was observed from 0.5 to 5000 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.14–5.56 and 0.25–12.3%, respectively. This novel method has been applied to a pharmacokinetic study and to estimate brain‐to‐plasma ratio of S‐CPM in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

18.
A rapid, sensitive and specific method using liquid chromatography with tandem mass spectrometric detection (LC‐MS) was developed for the analysis of sauchinone in rat plasma. Di‐O‐methyltetrahydrofuriguaiacin B was used as internal standard (IS). Analytes were extracted from rat plasma by liquid–liquid extraction using ethyl acetate. A 2.1 mm i.d. × 150 mm, 5 µm, Agilent Zorbax SB‐C18 column was used to perform the chromatographic analysis. The mobile phase was methanol–deionized water (80:20, v/v). The chromatographic run time was 7 min per injection and the flow‐rate was 0.2 mL/min. The tandem mass spectrometric detection mode was achieved with electrospray ionization interface in positive‐ion mode (ESI+). The m/z ratios [M + Na]+, m/z 379.4 for sauchinone and m/z 395.4 for IS were recorded simultaneously. Calibration curve were linear over the range of 0.01–5 µg/mL. The lowest limit of quantification was 0.01 µg/mL. The intra‐day and inter‐day precision and accuracy of the quality control samples were 2.94–9.42% and 95.79–108.05%, respectively. The matrix effect was 64.20–67.34% and the extraction recovery was 93.28–95.98%. This method was simple and sensitive enough to be used in pharmacokinetic research for determination of sauchinone in rat plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for simultaneous determination of urapidil and aripiprazole in human plasma. A simple liquid–liquid extraction with ethyl acetate was used for the sample preparation. Chromatographic separation was achieved on a Phenomenex C18 (4.6 × 50 mm, 5 µm) column with 0.1% formic acid–acetonitrile (10:90, v/v) as the mobile phase with flow rate of 0.6 mL/min. The quantitation of the target compounds was determined in a positive ion multiple reaction monitoring mode. Calibration plots were linear over the range of 2.0–2503.95 ng/mL for urapidil and 1.0–500.19 ng/mL for aripiprazole. The lower limit of quantitation for urapidil and aripiprazole was 2.0 and 1.0 ng/mL, respectively. Mean recovery was in the range of 69.94–75.62% for both analytes and internal standards. Intra‐day and inter‐day precisions of the assay at three concentrations were 2.56–5.89% with accuracy of 92.31–97.83% for urapidil, and 3.14–6.84% with accuracy of 91.38–94.42% for aripiprazole. The method was successfully applied to human pharmacokinetic study of urapidil and aripiprazole in healthy human male volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
Taraxasterol, a pentacyclic triterpene from Taraxacum officinale, is one of the main active constituents of the herb. This study developed and validated a highly selective and sensitive liquid chromatography/tandem mass spectrometry for the determination of taraxasterol in rat plasma over the range of 9.0–5000 ng/mL. Chromatographic separation was achieved on a C18 (4.6 × 50 mm, 5.0 µm) column with methanol–isopropanol–water–formic acid (80:10:10:0.1, v/v/v/v) as mobile phase with an isocratic elution. The flow rate was 0.7 mL/min. After adding cucurbitacin IIa as an internal standard (IS), liquid–liquid extraction was used for sample preparation using ethyl acetate. The atmospheric pressure chemical ionization source was applied and operated in positive ion mode. Selected reaction monitoring mode was used for the quantification of transition ions m/z 409.4 → 137.1 for taraxasterol and m/z 503.4 → 113.1 for IS. The mean recoveries of taraxasterol in rat plasma ranged from 85.3 to 87.2%. The matrix effects for taraxasterol were between 98.5 and 104.0%. Intra‐ and inter‐day precision were both <11.8%, and the accuracy of the method ranged from ?7.0 to 12.9%. The method was successfully applied to a pharmacokinetic study of taraxasterol after oral administration of 7.75, 15.5 and 31.0 mg/kg in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号