首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Piao D  Otis LL  Zhu Q 《Optics letters》2003,28(13):1120-1122
Accurate estimation of flow velocity requires measurement of Doppler angle, which is not available in general clinical applications. We describe a novel method of direct Doppler angle and flow velocity mapping that uses a conventional single-beam optical Doppler tomography system. The Doppler angle is estimated by combination of Doppler shift and Doppler bandwidth measurements, and flow velocity is calculated from the Doppler shift and the estimated Doppler angle. In vivo study of lip microvascularization demonstrates that this method is capable of providing both flow speed and flow direction information.  相似文献   

2.
Kim J  Oh J  Milner TE  Nelson JS 《Optics letters》2006,31(6):778-780
We introduce a novel contrast mechanism for imaging blood flow by use of magnetomotive optical Doppler tomography (MM-ODT), which combines an externally applied temporally oscillating high-strength magnetic field with ODT to detect erythrocytes moving according to the field gradient. Hemoglobin contrast was demonstrated in a capillary tube filled with moving blood by imaging the Doppler frequency shift, which was observed independently of blood flow rate and direction. Results suggest that MM-ODT may be a promising technique with which to image blood flow.  相似文献   

3.
分析了超音速射流由于高速相对运动产生多普勒谱线漂移效应对光辐射特性计算的影响。通过采用逐线计算法对不同环境压力、气流温度、气流速度条件下超音速燃气射流在不同的红外光谱区(2.7微米谱带和4.3微米谱带)光辐射谱带积分强度的计算结果比较表明:多普勒漂移效应受环境总压影响最大,压力越大多普勒漂移的影响越小;随着温度升高多普勒漂移效应的影响降低;随着相对速度的增加,多普勒漂移效应的影响多数情况下是增加的。  相似文献   

4.
光谱法测量等离子体离子温度和旋转速度   总被引:7,自引:4,他引:3  
徐伟  万宝年 《光学学报》2003,23(9):115-1118
分析多普勒展宽和多普勒频移的区别,讨论了弦积分的线形分布和高斯分布的差异,利用光谱多道分析仪测量了碳227.1nm谱线的线形分布,通过选点拟合得出辐射粒子的离子温度和旋转速度径向分布。  相似文献   

5.
In this study we demonstrate the usefulness of the Photoacoustic Spectroscopy (PAS) in the investigation of water collected from a natural site located within the Amazon region, Brazil, during the wet to dry seasons transition (May/2006). The water samples were collected from different stages along a hydrologic pathway including precipitation water (Prec), groundwater (GW), through flow water (TF), overland flow water (OF), and stream flow water (SW). The observed photoacoustic spectral features, in the 0.3 to 1.0 μm wavelength region, fall within three distinct bands (C, S, and L). We found band-C, band-S and band-L occurring in the spectral range of 0.30 to 0.40 μm, 0.40 to 0.45 μm and 0.45 to 1.0 μm regions, respectively. The photoacoustic features shift peak positions and change intensities for all samples investigated, thus supporting the proposal of PAS as a useful technique to investigate water samples from natural environments.  相似文献   

6.
分析了多普勒展宽和多普勒频移区别,讨论了高斯拟合和弦积分线形分布的差异。利用多道光学分析仪(OSMA)测量HT-6M托卡马克限制器前Hα线形分布,通过高斯拟合由多普勒展宽和多普勒频移分别得出等离子温度和粒子入射速度。  相似文献   

7.
Li PC  Huang SW  Wei CW  Chiou YC  Chen CD  Wang CR 《Optics letters》2005,30(24):3341-3343
A quantitative technique for flow measurements based on a wash-in analysis is proposed. The technique makes use of the shape dependence of the optical absorption of gold nanorods and the transitions in their shape induced by pulsed laser irradiation. The photon-induced shape transition of gold nanorods involves mainly a rod-to-sphere conversion and a shift in the peak optical absorption wavelength. The application of a series of laser pulses will induce shape changes in gold nanorods as they flow through a region of interest, with quantitative flow information being derived from the photoacoustic signals from the irradiated gold nanorods measured as a function of time. To demonstrate the feasibility of the technique, a Nd:YAG laser operating at 1064 nm was used for irradiation and a 1 MHz ultrasonic transducer was used for acoustic detection. The flow velocity ranged from 0.35 to 2.83 mm/s. Excellent agreement between the measured velocities and the actual velocities was demonstrated, with a linear regression correlation coefficient of 0.93. This study is a pioneer work on wash-in flow estimation in photoacoustic imaging.  相似文献   

8.
Monitoring blood flow velocity could have great value for biomedical research and clinical diagnostics. One of current restrictions to determine flow velocity by the use of Doppler optical coherence tomography (Doppler OCT) is that the Doppler angle should be predefined. However, from a practical point of view, it is not easy to predetermine Doppler angle for a flow beneath the tissue surface. In this work, a novel method for measuring both flow velocity and Doppler angle simultaneously by the use of Doppler OCT is proposed and demonstrated. Based on Doppler spectrum analysis, this technique measures both longitudinal and transverse components of flow velocity by detecting its Doppler shift and Doppler bandwidth to determine velocity and Doppler angle simultaneously. Such a technique extends flow velocity measurement into a broadening practical use of Doppler OCT where Doppler angle would not need to be predefined, for example, blood flow beneath the tissue surface. Therefore, with this technique, Doppler OCT could be applied to more practical diagnoses of microcirculation.  相似文献   

9.
Ren H  Brecke KM  Ding Z  Zhao Y  Nelson JS  Chen Z 《Optics letters》2002,27(6):409-411
The Doppler bandwidth extracted from the standard deviation of the frequency shift in phase-resolved functional optical coherence tomography (F-OCT) was used to image the velocity component that is transverse to the optical probing beam. It was found that above a certain threshold level the Doppler bandwidth is a linear function of flow velocity and that the effective numerical aperture of the optical objective in the sample arm determines the slope of this dependence. The Doppler bandwidth permits accurate measurement of flow velocity without the need for precise determination of flow direction when the Doppler flow angle is within +/-15 degrees perpendicular to the probing beam. Such an approach extends the dynamic range of flow velocity measurements obtained with the phase-resolved F-OCT.  相似文献   

10.
E A Barannik 《Ultrasonics》2001,39(4):311-317
The properties of the single flow-line Doppler spectrum using pulsed wave (PW) ultrasound is studied on the basis of previously developed spectral theory for transducers with apodized apertures. It has been shown previously that the spectral width of Doppler signals from a sample volume in low velocity-shear flow is independent of the sample volume depth but that is not true for the spectra from the individual streamlines. The work presented here on the Doppler flow-line spectrum shows that its width should be invariant with flow-line location, if the sample volume depth is fixed. At the same time, for a transducer operating in PW mode not only the Doppler spectral width depends on the sample volume depth, but also the modal Doppler frequency shift changes with flow-line displacement in the illuminating field except if the sample volume centre and the beam focus coincide. The variation of modal Doppler frequency shift is the more explicit manifestation of the effect of wavefront curvature increasing for lines and sounding depths distant from the focal point. The values of the Doppler shift and spectral bandwidth are reported taking account of beam diffraction and variations in its geometry due to focusing.  相似文献   

11.
光学相干层析多普勒成像功能拓展研究   总被引:8,自引:0,他引:8  
光学多普勒成像(Optical Doppler tomography,ODT)是一种结合了光学相干层析成像技术(Opticalcoherence tomography,OCT)和多普勒流速仪的非侵入、非接触的成像技术,能够实现对高散介质组织内部的血管分布和血液流速的探测。阐述了基于数字希尔伯特变换的相位分离多普勒光学相干层析成像技术的工作原理,并且通过对玻璃毛细管和生物芯片微通道管中聚苯乙烯溶液流速的实验测量,准确测量管内微粒缓慢移动时的多普勒频移量,获得了玻璃管内和生物芯片微通道管中流速分布曲线,证实了所提方法的可行性。获取的多普勒图像具有较高的空间分辨力和速度分辨力,在未来的临床应用中有潜在的应用价值。  相似文献   

12.
原子束在慢波场中的多普勒频移的观察   总被引:1,自引:0,他引:1  
李佛生  蔡惟泉 《光学学报》1998,18(10):286-1289
报道了在慢波场中原子波谱多普勒频移随微波慢波系数的变化,并讨论产生这种现象的原因,实验中观察到慢波场中的原子多普勒频移现象,给出了钠原子在慢小系数分别为5.20和10.67情况下的微波波谱,证实了原子微波慢波波谱中多普勒频移正比于慢波系数。  相似文献   

13.
程刚  曹亚南  田兴  刘锟  陈家金 《光子学报》2021,50(2):192-200
为了提高光声池的检测性能,提出并分析了一种阶梯复合形光声池。以传统圆柱共振型光声池为基准模型,通过对比解析与模拟计算结果,验证了所采用模拟方法的可靠性,基于模拟方法求解并获得了阶梯腔半径、阶梯腔长度和阶梯腔数量对阶梯复合形光声池声-流特性的影响规律。结果表明:减小阶梯复合形光声池中阶梯腔半径,光声信号相对增强,阶梯腔长度存在最佳尺寸使得光声信号达到最强,阶梯腔数目应选1为宜;流场方面,阶梯复合形光声池构型特征改善了腔内气体涡漩回流的情况,若进一步对其腔内过渡处进行圆角或倒角处理,腔内流速梯度将变得更为平稳。选择一组设计参数进行构型与计算,得到阶梯复合形光声池腔体容积降低为对应圆柱共振型光声池的39.7%,光声信号相对提升约18.7%,同时其频响带宽变窄,品质因数相对得到提升,整体结果显示阶梯复合形光声池声-流特性要优于对应的圆柱共振型光声池。研究内容可为光声光谱光声池的结构优化与改进提供参考。  相似文献   

14.
曹新亮  崔巍 《应用声学》2017,36(2):148-154
为了提高超声波多普勒法测量复杂流体流量的精度,针对流体的超声回波频率的复杂性,本文研究多普勒流速测量中的频偏提取方法。以傅里叶分析为理论基础,设计了硬件电路并获得代表回波平均频率的信号,然后以该信号作为输入,以数字鉴频法获得回波多普勒频移。基于该方法设计了一种超声多普勒流量测量系统,实验结果显示:油水混合流体流量的测量误差在3%以内,从而证实了此频偏提取方法的有效性。  相似文献   

15.
The chirp heterodyne technique allows a directional discrimination of laser Doppler velocity measurements without the use of additional frequency shift elements. This paper presents, for the first time, the use of a chirp frequency-modulated solid-state laser, emitting in the green spectral range. Experimental results of a fluid flow measurement verify the function of the realised chirp heterodyne laser Doppler velocimeter.  相似文献   

16.
Single-beam laser Doppler measurements of flow velocity are only sensitive to the velocity component parallel to the optical axis. We describe a simple modification to a standard Doppler optical coherence tomography (OCT) system using a single sample beam that provides velocity information from multiple angles within the beam. By introducing a glass plate midway into the OCT beam path, the sample beam is divided into several components, each with a different group delay and each providing a separate interferogram with its own effective Doppler angle. By combining the Doppler shift measured in each of these component interferograms, the flow velocity vector is fully determined.  相似文献   

17.
Retinal blood flow quantification by retinal vessel segmentation with Doppler optical coherence angiography is presented. Vessel diameter, orientation, and position are determined in an en face vessel image and two representative cross-sectional flow images of the vessel. Absolute blood flow velocity is calculated with the help of the measured Doppler frequency shift and determined vessel angle. The volumetric flow rate is obtained with the position and the region of the vessel lumen. The volumetric blood flow rate of retinal arteries before and after a bifurcation is verified in a healthy human eye.  相似文献   

18.
纳米材料ZrO2的傅里叶变换红外光声光谱研究   总被引:4,自引:3,他引:1  
刘方新  刘方平 《光学学报》1994,14(7):92-695
首次报道单斜ZrO2纳米材料在各种微晶粒度下的傅里叶变换红外光声光谱(FT-IR-PAS),发现随着粒度的减小,波数低于1048cm^-^1的谱线强度减弱,而波数高于1048CM^-^1的谱线强度增加,一些谱线位置有红移,并观察了压力效应。对上述量效应进行 初步解释。  相似文献   

19.
Some predictions are made on dynamic light scattering by critical fluids in the presence of a shear flow. A Doppler shift broadening is predicted to occur whenever the scattering vector has a component along the direction of flow.  相似文献   

20.
Since unsteady, complex flow phenomena play an important role, optical measurements techniques are required for flow investigations, which provide simultaneous measurements of multiple velocity components. Doppler global velocimetry has this potential. It is a flow measurement technique, where the Doppler shift of scattered light is measured by a molecular absorption cell for frequency-to-intensity conversion. However, novel Doppler global velocimeters with laser frequency modulation were only used for single component measurements yet. In order to enhance such a system for the simultaneous measurement of multiple components, a concept based on frequency division multiplexing is introduced for the first time. Besides multiple lasers, only a single molecular absorption cell and a single detector unit is required. Two-component measurements of velocity profiles from nozzle flows are presented as a proof of principle. The designed measurement system provides high measurement rates of up to 20 kHz, which is three orders of magnitude higher than for typical Doppler global velocimetry setups.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号