首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sequential injection (SI) method for the determination of mercury via cold vapor atomic absorption spectrophotometry is presented. The method differs from flow injection (FI) cold vapor methods for the determination of mercury because of the simplicity of the system required for the method: one pump, one valve, a gas-liquid separator, and an atomic absorption spectrophotometer equipped with a quartz cell. Under optimal conditions, the method has the following figures of merit: a linear calibration range of 1.0 to 20 microg L(-1); a detection limit of 0.46 microg L(-1); and a precision of 0.90% RSD (8 microg L(-1)). The procedure allows for a sampling rate of one injection per 80 s (excluding sample pretreatment). Results from the determination of mercury in water and fish specimens are also presented. The figures of merit of the method are compared to two other SI methods for the determination of mercury.  相似文献   

2.
An ultraviolet-photochemical generator (UV-PVG) capable of post-column on-line transformation of both organic and inorganic mercury species to cold vapor (Hg0) with subsequent detection by quartz tube-atomic absorption spectrometry (QT-AAS) was developed. Mercury(II), methylmercury(I), ethylmercury(I), and phenylmercury(I) were successfully detected after separation by reversed-phase high-performance liquid chromatography (RP-HPLC). Two types of AAS detectors were compared. The first was a commonly used line-source instrument while the second was a high-resolution continuum source (HR-CS) AAS. The latter provided better limits of detection: 0.47?µg?L?1 for Hg(II), 0.84?µg?L?1 for methylmercury(I), 0.80?µg?L?1 for ethylmercury(I), and 2.0?µg?L?1 for phenylmercury(I). The repeatability at 30?μg?L?1 was 3.6%, 4.1%, 6.2%, and 4.5% for these species (n?=?10). These figures of merit were comparable with those reported for more sensitive atomic fluorescence spectrometry. Nine sample extraction procedures were investigated. Extraction by tetramethylammonium hydroxide and HCl at 75?°C was selected as the only method compatible with the proposed separation and detection steps providing high extraction efficiency and no changes in mercury speciation. The applicability of the proposed high-performance liquid chromatography–ultraviolet-photochemical vapor generation–quartz tube-atomic absorption spectrometry method was demonstrated using fish samples and certified reference materials (CRM) DOLT-4 (dogfish liver) and ERM-CE464 (tuna fish). The results were comparable to those obtained by a reference method based on L-cysteine extraction and high-performance liquid chromatography–inductively coupled plasma-mass spectrometry (HPLC–ICP-MS) determination.  相似文献   

3.
Low recovery rate and inconsistent measurements were found in the determination of mercury by method of cold vapor atomic absorption spectrophotometry using the hydride formation system (Hitachi HFS-2, Hitachi Ltd., Tokyo). To overcome this problem of insufficient reaction time we developed a simple T-joint device attaching to the commercial HFS-2 system for the determination of mercury in various biological tissues and sediment samples. The T-joint device was designed to combine sample and reductant injection which increased the reaction time of the sample allowing a complete formation of mercury vapor and speeding up the analysis process in comparison to the traditional cold vapor atomic absorption spectrometric method. Recoveries of mercury were in the range 95% - 100%. The corrected procedure gave precise and accurate readings with several certified reference materials: NIES No. 2 from the Japan Environment Agency; IAEA-356 from the International Atomic Energy Association, and DOLT-2, DORM-2, TORT-2, PACS-1 and MESS-2 from the National Research Council of Canada. Simple acid digestion methods were developed based on the sample Hg level and the nature of the sample. The sample detection limits were 0.0125 μg g−1 fresh weight and 0.0625 μg g−1 dry weight for biological samples, and as low as 0.0125 μg g−1 dry weight for sediment samples. These analytical protocols we established met the general requirements in environmental research and monitoring of mercury pollution.  相似文献   

4.
A simple, fast, and sensitive method for speciation and determination of As (III, V) and Hg (II, R) in human blood samples based on ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and flow injection hydride generation/cold vapor atomic absorption spectrometry (FI-HG/CV-AAS) has been developed. Tetraethylthiuram disulfide, mixed ionic liquids (hydrophobic and hydrophilic ILs) and acetone were used in the DLLME step as the chelating agent, extraction and dispersive solvents, respectively. Using a microwave assisted-UV system, organic mercury (R-Hg) was converted to Hg(II) and total mercury amount was measured in blood samples by the presented method. Total arsenic content was determined by reducing As(V) to As(III) with potassium iodide and ascorbic acid in a hydrochloric acid solution. Finally, As(V) and R-Hg were determined by mathematically subtracting the As(III) and Hg(II) content from the total arsenic and mercury, respectively. Under optimum conditions, linear range and detection limit (3σ) of 0.1–5.0 µg L?1 and 0.02 µg L?1 for As(III) and 0.15–8.50 µg L?1 and 0.03 µg L?1 for Hg(II) were achieved, respectively, at low RSD values of < 4% (N = 10). The developed method was successfully applied to determine the ultra-trace amounts of arsenic and mercury species in blood samples; the validation of the method was performed using standard reference materials.  相似文献   

5.
A simple and sensitive flow injection analysis-atomic absorption spectrometric procedure is described for the determination of cobalt. The method is based upon on-line preconcentration of cobalt on a microcolumn of 2-nitroso-1-naphthol immobilized on surfactant coated alumina. The trapped cobalt is then eluted with ethanol (250 μl) and determined by flame atomic absorption spectrometry. The analytical figures of merit for the determination of cobalt are as follows: detection limit (3 S), 0.02 ng ml−1; precision (RSD), 2.8% for 20 ng ml−1 and 1.7% for 70 ng ml−1 of cobalt; enrichment factor, 125 (using 25 ml of sample). The method has been applied to the determination of cobalt in water samples, vitamin B12 and B-complex ampoules and accuracy was assessed through recovery experiment and independent analysis by furnace AAS.  相似文献   

6.
A method was developed for the generation of a “cold vapor” of cadmium by means of flow injection-chemical vapor generation from aqueous samples, the determination being conducted with an atomic absorption spectrometer (Pyrex glass T-cell). Several gas-liquid separator designs, atomizer designs, and the effect of several reagents previously reported as sensitivity enhancers (including cobalt, nickel, thiourea and didodecyl-dimethylammonium bromide) were investigated. The limit of detection, calculated as the concentration giving a signal equal to three times the standard deviation of the blank, was 16 ng L–1, and the relative standard deviation was 1.4% for a concentration of 2 μg L–1 and 3.8% for 0.1 μg L–1. The addition of nickel and thiourea to the samples provided improved tolerance to the interference of coexisting ions. Two NIST certified reference materials, Montana Soil and Apple Leaves (respectively containing ¶41.7 ± 0.25 mg kg–1 Cd and 0.013 ± 0.002 mg kg–1 Cd) were accurately analyzed. The interference of lead was overcome by coprecipitation with barium sulfate, and the experimental values obtained were 41 ± 1 mg kg–1 Cd and 0.013 ± 0.002 mg kg–1 Cd, respectively.  相似文献   

7.
With UV irradiation, Hg2+ in aqueous solution can be converted into Hg0 cold vapor by low molecular weight alcohols, aldehydes, or carboxylic acids, e.g., methanol, formaldehyde, acetaldehyde, glycol, 1,2-propanediol, glycerol, acetic acid, oxalic acid, or malonic acid. It was found that the presence of nano-TiO2 more or less improved the efficiency of the photo-induced chemical/cold vapor generation (photo-CVG) with most of the organic reductants. The nano-TiO2-enhanced photo-CVG systems can be coupled to various analytical atomic spectrometric techniques for the determination of ultratrace mercury. In this work, we evaluated the application of this method to the atomic fluorescence spectrometric (AFS) determination of mercury in cold vapor mode. Under the optimized experimental conditions, the instrumental limits of detection (based on three times the standard deviation of 11 measurements of a blank solution) were around 0.02–0.04 μg L−1, with linear dynamic ranges up to 15 μg L−1. The interference of transition metals and the mechanism of the photo-CVG are briefly discussed. Real sample analysis using the photo-CVG-AFS method revealed that it was promising for water and geological analysis of ultralow levels of mercury. Image of the photo-CVG instrumentation showing the photoreactor inside the water cooling unit  相似文献   

8.
研究了聚四氟乙烯管编结反应器(KR)在线吸附预富集技术与冷蒸气原子荧光联用测定矿泉水中痕量无机汞的方法.Hg2+与DDTC在线形成Hg2+-DDTC络合物并吸附在KR内壁上,采用电磁感应加热技术,用20% (V/V) HNO3在线加热洗脱并氧化预富集于KR内壁上的Hg2+-DDTC.洗脱液与KBH4溶液反应生成蒸气态汞,直接用冷蒸气原子荧光联用技术检测.20%(V/V)HNO3作为洗脱液的同时也为氢化发生提供了酸性介质.本方法未使用常用的有机洗脱液,具有操作简单和环保等优点.每小时可分析30个样品,最大吸附倍数为35倍,样品分析精密度RSD为2.2%(n=11),检出限(3σ)为2.0 ng/L.  相似文献   

9.
《Analytical letters》2012,45(13):2195-2208
A sensitive and simple method for the determination of trace nickel was developed by the combination of dispersive liquid–liquid microextraction (DLLME) and microsample injection system–flame atomic absorption spectrometry (MIS–FAAS). Trace nickel was preconcentrated as the 8-hydroxyquinoline chelate by DLLME, and the conditions were optimized by a Plackett-Burman design. Quantitative recovery of nickel (98 ± 1%) was obtained by a sample volume of 7.5 mL at a pH of 6.0. The enrichment factor was 52.5, and the limits of detection and quantitation were 0.1 µ g L?1 and 3.0 µ g L?1, respectively. The method was validated by the analysis of a wastewater standard reference material, water samples, and a wire sample. The reported method has superior analytical figures of merit compared with similar methods reported in the literature.  相似文献   

10.
A dual direct method for the ultratrace determination of thallium in natural waters by differential pulse anodic stripping voltamrnetry (d.p.a.s.v.) is presented. D.p.a.s.v. at the hanging mercury drop electrode and at the mercury film electrode is used in the concentration ranges 0.5–100 μg Tl l-1, and 0.01–10 μg Tl l-1, respectively. Quantification is aided by the technique of standard additions. The response of the method is optimized for typical natural surface water matrices. An intercomparison of thalium determinations performed by the two anodic stripping methods and electrothermal-atomization atomic absorption spectrometry on normal and thallium-spiked surface water samples demonstrates equivalent accuracy within the range where atomic absorption is applicable. The method appears free from serious interferences.  相似文献   

11.
A rugged and reliable method for the determination of mercury in coal without sample digestion, based on chemical vapor generation (cold vapor technique) from slurried coal samples has been developed. It involves collection of the mercury vapor in a graphite tube, treated with gold or rhodium as permanent modifier, and determination by electrothermal atomic absorption spectrometry. Mercury quantitatively leached out of the investigated coal reference materials into 1 mol l−1 nitric acid within 48 h when the coal was ground to a particle size of ≤50 μm, except for one sample (BCR 180), which had to be ground to ≤30 μm, or a leaching time of 72 h had to be used. No detectable quantity of mercury was generated directly from the slurry particles, but it was not necessary to filter the solution. The greatest advantage of the method is that only a minimum of reagents and sample handling steps are required, a prerequisite for accurate results in routine analysis. The results were well within the 95% confidence level of the certificate or close to the information value of the reference materials investigated. The characteristic mass of 110 pg obtained with gold as the permanent modifier is close to values reported for direct analysis of solutions, showing close to 100% trapping efficiency for mercury. A limit of detection (LOD) of 90 pg absolute was obtained with this modifier, which corresponds to an LOD of 0.009 μg g−1 Hg in coal. This is based on 1 ml of slurry containing 10 mg of coal, and is an order of magnitude lower than the lowest mercury content in the investigated reference materials.  相似文献   

12.
Kagaya S  Kuroda Y  Serikawa Y  Hasegawa K 《Talanta》2004,64(2):554-557
Addition of a sodium hypochlorite solution (9.2% (w/v)) was effective to reduce a sulfide interference in determination of organic mercury, including methylmercury and phenylmercury, as well as a previously reported determination of inorganic mercury by cold vapor atomic absorption spectrometry (CVAAS) in an alkaline medium. Total mercury ranging from 0.17 to 33 μg L−1 in 15 mL of sample solutions containing up to 200 mg L−1 of sulfide can be determined without any serious interference by sulfide when 1 mL of the sodium hypochlorite solution was added after dilution of the sample solution to 25 mL. The proposed method was simple and rapid because no digestion processes were required for the determination of total mercury; the time required for the determination was only about 5 min. The proposed method was applicable to the analysis of treated waste water.  相似文献   

13.
The simultaneous “in natura” determination of trace Zn, Pb and Cu in whisky samples by anodic stripping voltammetry (ASV), using a hanging mercury drop electrode, without previous treatment or addition of supporting electrolyte is described. The choice of an appropriate stripping voltammetric method and deposition potential minimizes the influence of the organic content and ensures a good reproducibility of the measurements. The reliability of the method was tested comparing the results with those of atomic absorption spectroscopy (AAS), with differences of about 10%. The method allows the determination of heavy metal ions in the μg L–1 range.  相似文献   

14.
Li X  Wang Z 《Analytica chimica acta》2007,588(2):179-183
A novel method for determination of mercury was developed using an intermittent flow electrochemical cold vapor generation coupled to atomic fluorescence spectrometry (IF-ECVG-AFS). The mercury vapor was generated on the surface of glassy carbon cathode in the flow cell. The operating conditions for the electrochemical generation of mercury vapor were investigated in detail, and the interferences from various ions were evaluated. Under the optimized conditions, no evident memory effects of mercury were observed. The calibration curve was linear up to 5 μg L−1 Hg at 0.54 A cm−2. A detection limit of 1.2 ng L−1 Hg and a relative standard deviation of 1.8% for 1 μg L−1 Hg were obtained. The accuracy of method was verified by the determination of mercury in the certified reference human hair. The ECVG avoided the use of reductants, thereby greatly reducing the contamination sources. In addition, the manifold of IF-ECVG-AFS was simple and amenable to automation.  相似文献   

15.
Pollution from heavy metals has increased in recent decades and has become an important concern for environmental agencies. Arsenic, cadmium, copper, mercury and lead are among the trace elements that have the greatest impact and carry the highest risk to human health. Electrothermal atomic absorption spectrometry (ETAAS) has long been used for trace element analyses and over the past few years, the main constraints of atomic absorption spectrometry (AAS) methods, namely matrix interferences that provoked high background absorption and interferences, have been reduced. The use of new, more efficient modifiers and in situ trapping methods for stabilization and pre-concentration of these analytes, progress in control of atomization temperatures, new designs of atomizers and advances in methods to correct background spectral interferences have permitted an improvement in sensitivity, an increase in detection power, reduction in sample manipulation, and increase in the reproducibility of the results. These advances have enhanced the utility of Electrothermal atomic absorption spectrometry (ETAAS) for trace element determination at μg L1 levels, especially in difficult matrices, giving rise to greater reproducibility, lower economic cost and ease of sample pre-treatment compared to other methods. Moreover, the recent introduction of high resolution continuum source Electrothermal atomic absorption spectrometry (HR-CS-ETAAS) has facilitated direct solid sampling, reducing background noise and opening the possibility of achieving even more rapid quantitation of some elements. The incorporation of flow injection analysis (FIA) systems for automation of sample pre-treatment, as well as chemical vapor generation renders (ETAAS) into a feasible option for detection of As and Hg in environmental and food control studies wherein large numbers of samples can be rapidly analyzed. A relatively inexpensive approach with low sample consumption provide additional advantages of this technique that reaches figures of merit equivalent to Inductively coupled plasma mass spectrometry (ICP-MS). Herein is presented an overview of recent advances and applications of (ETAAS) for the determination of As, Cd, Cu, Hg and Pb in biological samples drawn from studies over the last decade.  相似文献   

16.
A method for determination of inorganic and total mercury by flow injection-cold vapor atomic absorption spectrometry (FI-CVAAS) with on-line oxidation was developed. Potassium peroxodisulphate and sulphuric acid were used as oxidizing agents so that decomposition of organomercury compounds could be achieved. Depending on the temperature selected, inorganic or total mercury could be determined with the same FI manifold. In order to assess the method performance, synthetic wastewater, wastewater, urine and saline water samples were spiked with inorganic mercury, methylmercury and phenylmercury. Quantitative recoveries were obtained for the three mercury species, except with the synthetic wastewater when the chemical oxygen demand value was higher than 1000 mg l−1. In most cases, the standard addition method was usually needed for calibration. LODs calculated as 3 σ/m were 0.47 μg l−1 for inorganic mercury and 0.45 μg l−1 for total mercury. R.S.D. values corresponding to peak height measurements were 1.5 and 2.2% for inorganic mercury and total mercury, respectively. The accuracy of the method was tested by analyzing 5 mol l−1 hydrochloric acid extracts of seven biological and environmental CRMs. LODs in the solid CRMs ranged from 0.032 to 0.074 μg g−1.  相似文献   

17.
The development of a preconcentration method for the measurement of trace levels of mercury in digested sediments is described. Solid phase extraction (SPE) was used for the preconcentration of mercury coupled on-line by means of a flow injection (FI) system followed by cold vapour atomic absorption spectrometry (CVAAS) detection. The SPE was carried out through a column packed with a sorbent material containing triisobutylphosphine sulfide (CYANEX 471X®) as mercury extractant and prepared by the sol-gel process. The effects of FI variables (argon, eluent, and reductant flow rates, loading and elution times) as well as the eluent concentration on the analytical performance of the method were evaluated. The proposed method was validated under the optimum conditions. The calibration graph was linear from 0.05?µg?L?1 to 3.0 µg?L?1 of Hg. The detection limit (DL), based on three times the standard deviation of the blank measurement criterion, was 24?ng?L?1. The repeatability was 1.5% and 1.8% RSD (n?=?10) at concentrations of 0.5 and 1 µg?L?1 of Hg, respectively. Method enrichment factors of 16 with a productivity of 30 samples h?1 or 32 with a productivity of 17 samples h?1 were achieved under selected conditions. Certified reference materials, inductively coupled plasma mass spectroscopy (ICP-MS) and cold vapour atomic fluorescence spectrometry (CVAFS), were used to evaluate the accuracy of the proposed method.  相似文献   

18.
A method for organic, inorganic and total mercury determination in fish tissue has been developed using chemical vapor generation and collection of mercury vapor on a gold gauze inside a graphite tube and further atomization by electrothermal atomic absorption spectrometry. After drying and cryogenic grinding, potassium bromide and hydrochloric acid solution (1 mol L− 1 KBr in 6 mol L− 1 HCl) was added to the samples. After centrifugation, total mercury was determined in the supernatant. Organomercury compounds were selectively extracted from KBr solution using chloroform and the resultant solution was back extracted with 1% m/v L-cysteine. This solution was used for organic Hg determination. Inorganic Hg remaining in KBr solution was directly determined by chemical vapor generation electrothermal atomic absorption spectrometry. Mercury vapor generation from extracts was performed using 1 mol L− 1 HCl and 2.5% m/v NaBH4 solutions and a batch chemical vapor generation system. Mercury vapor was collected on the gold gauze heated resistively at 80 °C and the atomization temperature was set at 650 °C. The selectivity of extraction was evaluated using liquid chromatography coupled to chemical vapor generation and determination by inductively coupled plasma mass spectrometry. The proposed method was applied for mercury analysis in shark, croaker and tuna fish tissues. Certified reference materials were used to check accuracy and the agreement was better than 95%. The characteristic mass was 60 pg and method limits of detection were 5, 1 and 1 ng g− 1 for organic, inorganic and total mercury, respectively. With the proposed method it was possible to analyze up to 2, 2 and 6 samples per hour for organic, inorganic and total Hg determination, respectively.  相似文献   

19.
An online mercury preconcentration and determination system consisting of cold vapor atomic absorption spectrometry (CV-AAS) coupled to a flow injection (FI) method was studied. The method was developed involving the determination of ng/L levels of mercury retained on the silver wool solid sorbent. Experimental conditions such as sample volume, flow rate, stability of the column and effect of foreign ions on the determination of trace amounts of mercury were optimized. The detection limit is 3 ng/L and dynamic range 10–250 ng/L require only 50 mL of sample. The relative standard deviations (RSD) of the determinations are below 4%. The presence of common metal ions, such as K+, Na+, Cu2+, Pb2+, Fe3+, Ni2+, and Mn2+, does not interfere with the measurement of mercury by this method. The method was successfully applied to the determination of mercury in water and wastewater samples.  相似文献   

20.
《Analytical letters》2012,45(11):1921-1930
This paper describes a simple and sensitive method for the determination of manganese in human urine by graphite furnace atomic absorption spectroscopy (GFAAS), which includes sample preparation by microwave digestion. Matrix modifier combinations, the digestion power, pyrolysis, and atomization temperatures were optimized. A mixture of 5.0 µg Pd(NO3)2 and 3.2 µg Mg(NO3)2 modifier presented the best performance. The optimal temperatures for pyrolysis and atomization were 1500°C and 1950°C, respectively. The GFAAS method was compared to inductively coupled plasma–mass spectrometry (ICP–MS) for the determination of manganese in urine. Analytical figures of merit for GFAAS and ICP–MS were: accuracy (3.46%, 2.19%), precision (3.61%, 5.84%), LOD (0.109 µg · L?1, 0.015 µg · L?1), LOQ (0.327 µg · L?1, 0.045 µg · L?1), and recovery (80–100%, 74–89%). Both methods were employed for the determination of Mn in urine and the results were compared statistically.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号