相似文献
 共查询到20条相似文献,搜索用时 875 毫秒
1.
The simultaneous determination of cobalt, copper and nickel using 1-(2-thiazolylazo)-2-naphthol (first figure of this article) by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 550-750-nm range for 21 different mixtures of cobalt, copper and nickel. Calibration matrices were formed from samples containing 0.05-1.05, 0.05-1.30 and 0.05-0.80 μg·mL^-1 for cobalt, copper and nickel, respectively. The root mean square error of prediction (RMSEP) for cobalt, copper and nickel with OSC and without OSC were 0.007, 0.008, 0.011 and 0.031,0.037, 0.032 μg· mL^-1, respectively. This procedure allows the simultaneous determination of cobalt, copper and nickel in synthetic and real samples and good reliability of the determination was proved.  相似文献   

2.
The simultaneous determination of cypermethrin and tetramethrin mixtures by using spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 200-350 nm range for 25 different mixtures of cypermethrin and tetramethrin. Calibration matrices were containing 0.1-12.9 and 0.1-13.8 microg mL(-1) for cypermethrin and tetramethrin, respectively. The RMSEP for cypermethrin and tetramethrin with OSC and without OSC were 0.0884, 0.0614 and 0.2915, 0.2309, respectively. This procedure allows the simultaneous determination of cypermethrin and tetramethrin in synthetic and real samples good reliability of the determination was proved.  相似文献   

3.
The simultaneous determination of manganese(II) and iron(II) mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used to remove the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of manganese(II) and iron(II). Calibration matrices were containing 0.05-1.2 and 0.1-2.3 microg mL(-1) Mn(II) and Fe(II), respectively. The RMSEP for manganese(II) and iron(II) with OSC and without OSC were 0.0316, 0.0291, and 0.0907, 0.115, respectively. This procedure allows the simultaneous determination of manganese(II) and iron(II) in synthetic and real matrix samples with good reliability of the determination.  相似文献   

4.
A simple, novel and sensitive spectrophotometric method was described for simultaneous determination of mercury and palladium. The method is based on the complex formation of mercury and palladium with Thio-Michler's Ketone (TMK) at pH 3.5. All factors affecting on the sensitivity were optimized and the linear dynamic range for determination of mercury and palladium found. The simultaneous determination of mercury and palladium mixtures by using spectrophotometric method is a difficult problem, due to spectral interferences. By multivariate calibration methods such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 360-660 nm range for 25 different mixtures of mercury and palladium. Calibration matrices were containing 0.025-1.60 and 0.05-0.50 microg mL(-1) of mercury and palladium, respectively. The RMSEP for mercury and palladium with OSC and without OSC were 0.013, 0.006 and 0.048, 0.030, respectively. This procedure allows the simultaneous determination of mercury and palladium in synthetic and real matrix samples good reliability of the determination.  相似文献   

5.
Ghasemi J  Niazi A 《Talanta》2005,65(5):1168-1173
The simultaneous determination of nitroaniline isomer mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removes the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 200–500 nm range for 21 different mixtures of nitroaniline isomers. Calibration matrices were containing 1–21, 1–15 and 1–18 μg ml−1 of m-nitroaniline, o-nitroaniline and p-nitroaniline, respectively. The RMSEP for m-nitroaniline, o-nitroaniline and p-nitroaniline with OSC and without OSC were 0.6567, 0.2692, and 0.3134, and 1.3818, 1.2181, and 0.3953, respectively. This procedure allows the simultaneous determination of nitroaniline isomers in real matrix samples and good reliability of the determination was proved.  相似文献   

6.
王凡凡  任守信  孟和  高玲 《分析化学》2011,39(6):915-919
根据正交信号校正(OSC)、小波包变换(WPT)及偏最小二乘法(PLS)的算法原理,编制了名为POSC-WPTPLS的程序,结合荧光分析法快速、灵敏、选择性较好的优点,将该程序用于同时测定荧光光谱严重重叠的萘、1-萘酚和2-萘酚多组分体系,并将3种化学计量学方法(OSC-WPT-PLS、WPT-PLS和PLS)进行比较...  相似文献   

7.
Multivariate regression based on partial least squares (PLS2) was applied to estimating one spectral dataset from another set having an intrinsic relationship with each other. An estimation was successfully carried out between mid-infrared (IR) spectra in the range of 2980 - 3800 cm(-1) and that of near-infrared (NIR) spectra in the range of 6000 - 7500 cm(-1) for hexafluoroisopropanol (HFIP)-water mixtures. The result demonstrates that, after building a suitable regression model, not only NIR spectra, but also well-resolved IR spectra of HFIP-water mixture can be estimated properly in this way. The use of IR and NIR spectroscopy together with PLS2 regression will not only alleviate laborious and costly measurements, but also open a way to provide easier assignments of generally weak and highly overlapped NIR spectral bands.  相似文献   

8.
A spectrophotometric method for the simultaneous determination of the important pharmaceuticals, pefloxacin and its structurally similar metabolite, norfloxacin, is described for the first time. The analysis is based on the monitoring of a kinetic spectrophotometric reaction of the two analytes with potassium permanganate as the oxidant. The measurement of the reaction process followed the absorbance decrease of potassium permanganate at 526nm, and the accompanying increase of the product, potassium manganate, at 608nm. It was essential to use multivariate calibrations to overcome severe spectral overlaps and similarities in reaction kinetics. Calibration curves for the individual analytes showed linear relationships over the concentration ranges of 1.0-11.5mgL(-1) at 526 and 608nm for pefloxacin, and 0.15-1.8mgL(-1) at 526 and 608nm for norfloxacin. Various multivariate calibration models were applied, at the two analytical wavelengths, for the simultaneous prediction of the two analytes including classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), radial basis function-artificial neural network (RBF-ANN) and principal component-radial basis function-artificial neural network (PC-RBF-ANN). PLS and PC-RBF-ANN calibrations with the data collected at 526nm, were the preferred methods-%RPE(T) approximately 5, and LODs for pefloxacin and norfloxacin of 0.36 and 0.06mgL(-1), respectively. Then, the proposed method was applied successfully for the simultaneous determination of pefloxacin and norfloxacin present in pharmaceutical and human plasma samples. The results compared well with those from the alternative analysis by HPLC.  相似文献   

9.
The use of visible (VIS) and near infrared spectroscopy (NIRS) to measure the concentration of elements in Australian wines was investigated. Both white (n=32) and red (n=94) wine samples representing a wide range of varieties and regions were analysed by inductively coupled plasma mass spectrometry (ICP-MS) for the concentrations of calcium (Ca), potassium (K), magnesium (Mg), phosphorus (P), sodium (Na), sulphur (S), iron (Fe), boron (B) and manganese (Mn). Samples were scanned in transmittance mode (1mm path length) in a monochromator instrument (400-2500nm). The spectra were pre-treated by second derivative and standard normal variate (SNV) prior to developing calibration models using partial least squares (PLS) regression method with cross-validation. The highest coefficients of determination in cross-validation (R(val)(2)) and the lowest errors of cross-validation (SECV) were obtained for Ca (0.90 and 9.80mgL(-1)), Fe (0.86 and 0.65mgL(-1)) and for K (0.89 and 147.6mgL(-1)). Intermediate R(val)(2) (<0.80) and SECV were obtained for the other minerals analysed. The results showed that some macro- and microelements present in wine might be measured by VIS-NIRS spectroscopy.  相似文献   

10.
A novel chemometric method, region orthogonal signal correction (ROSC), is proposed and applied to pretreat near-infrared (NIR) spectra of blood glucose measured in vivo. Water is the most serious interference component in such kinds of noninvasive measurements, because it shows very high absorbance in the spectra. In the present study, the spectra of blood glucose in the range of 1212 - 1889 nm are used, in which the absorption of water around 1440 nm is very high. ROSC aims at removing the interference signal due to water from the spectra by selecting a set of spectra with a special region of 1404 - 1454 nm that mainly contain information about the variation of the interference component, water, and calculating the orthogonal components to the concentrations of glucose that will be removed. The difference between ROSC and orthogonal signal correction (OSC) is that ROSC uses a special region of spectra for the estimation of scores and loading weights of orthogonal components to pretreat the spectra in other regions, while OSC only uses one fixed region of spectra to calculate loadings, scores and weights of OSC components and removes the OSC components in the same region. A clear advantage of ROSC is that it is more interpretable than OSC, because one can select a spectral region to remove the variation of a special component such as water. Another chemometric method, moving window partial least squares (MWPLSR), is also used to select informative regions of glucose from the NIR spectra of blood glucose measured in vivo, leading to improved PLS models. Results of the application of ROSC demonstrate that ROSC-pretreated spectra including the whole spectral region of 1212 - 1889 nm or an informative region of 1600- 1730 nm selected by MWPLSR provide very good performance of the PLS models. Especially, the later region yields a model with RMSECV of 15.8911 mg/dL for four PLS components. ROSC is a potential chemometric technique in the pretreatment of various spectra.  相似文献   

11.
In the present work, five different spectrophotometric techniques for simultaneous determination of formulations containing atorvastatin calcium (ATOR) and fenofibrate (FENO) in various combinations are described. In ratio spectra derivative spectrophotometry, analytical signals were measured at wavelengths corresponding to either maximums or minimums for both drugs in first derivative spectra of ratio spectra obtained by using either spectrum as divisor. For the remaining four methods using chemometric techniques, namely, classical least squares (CLS), inverse least squares (ILS), principal component regression (PCR) and partial least squares (PLS), the calibrations were constructed by using the absorption data matrix corresponding to the concentration data matrix, with measurements in the range of 231 - 310 nm (Deltalambda = 1 nm) in their zero-order spectra. The linearity range was found to be 4 - 22 and 2 - 20 microg/ml for ATOR and FENO, respectively. The validity of the proposed methods was successfully assessed for analyses of both drugs in laboratory-prepared mixtures and in commercial tablet formulations.  相似文献   

12.
混合线性分析-分光光度法同时测定微量铁和铝   总被引:5,自引:0,他引:5  
王晓佳  王保宁 《分析化学》2001,29(2):142-145
研究将混合线性分析(hybrid linear analysis,HLA)用于光谱分辨同时光度测定Fe^3 和Al^3 。在碱性条件下,Fe^3 和Al^3 与水杨基荧光酮生成光谱相互重叠的有色络合物,其浓度在0-320μ/L Fe^3 和0-160μg/L Al^3 范围内与吸光度呈良好线性关系。在550nm-630nm内取41个波长测量7组标准混合溶液的吸光度作为校正集,用最小二乘法求得的系数矢量作为各组分的纯光谱。以HLA法进行数据处理,在Fe^3 :Al^3 浓度为10:1-1:8范围内测定回收率为93.3%-107.5%。将本法与偏最小二乘法(PLS)法进行了比较,本法获得了较好的准确度和精密度。  相似文献   

13.
弓晓峰  黄坚锋 《分析化学》1994,22(9):935-938
本文将偏最小二乘法结合同步荧光扫描技术对含维生素B1,B2和B6的混合物进行了同时测定。对同步荧光法的测定条件及△λ的选择进行了试验和讨论,比较了△λ分别为65nm和30nm时的计算结果。所建立的方法用于复合维生素B片等药片叶B1,B2和B6孤同时测定,获较满意的结果。  相似文献   

14.
New approach for chemometrics algorithm named region orthogonal signal correction (ROSC) has been introduced to improve the predictive ability of PLS models for biomedical components in blood serum developed from their NIR spectra in the 1280-1849 nm region. Firstly, a moving window partial least squares regression (MWPLSR) method was employed to locate the region due to water as a region of interference signals and to find the informative regions of glucose, albumin, cholesterol and triglyceride from NIR spectra of bovine serum samples. Next, a novel chemometrics method named searching combination moving window partial least squares (SCMWPLS) was used to optimize those informative regions. Then, the specific regions that contained the information of water, glucose, albumin, cholesterol and triglyceride were obtained. When an interested component in the bovine serum solution, such as glucose, albumin, cholesterol or triglyceride is being an analyte, the other three interests and water are considered as the interference factors. Thus, new approach for ROSC has employed for each specific region of interference signal to calculate the orthogonal components to the concentrations of analyte that were removed specifically from the NIR spectra of bovine serum in the region of 1280-1849 nm and the highest interference signal for model of analyte will be revealed. The comparison of PLS results for glucose, albumin, cholesterol and triglyceride built by using the whole region of original spectra and those developed by using the optimized regions suggested by SCMWPLS of original spectra, spectra treated OSC for orthogonal components of 1-3 and spectra treated ROSC using selected removing the highest interference signals from the spectra for orthogonal components of 1-3 are reported. It has been found that new approach of ROSC to remove the highest interference signal located by SCMWPLS improves of the performance of PLS modeling, yielding the lower RMSECV and smaller number of PLS factors.  相似文献   

15.
The quantitative predictive abilities of the new and simple bivariate spectrophotometric method are compared with the results obtained by the use of multivariate calibration methods [the classical least squares (CLS), principle component regression (PCR) and partial least squares (PLS)], using the information contained in the absorption spectra of the appropriate solutions. Mixtures of the two drugs Nifuroxazide (NIF) and Drotaverine hydrochloride (DRO) were resolved by application of the bivariate method. The different chemometric approaches were applied also with previous optimization of the calibration matrix, as they are useful in simultaneous inclusion of many spectral wavelengths. The results found by application of the bivariate, CLS, PCR and PLS methods for the simultaneous determinations of mixtures of both components containing 2-12microgml(-1) of NIF and 2-8microgml(-1) of DRO are reported. Both approaches were satisfactorily applied to the simultaneous determination of NIF and DRO in pure form and in pharmaceutical formulation. The results were in accordance with those given by the EVA Pharma reference spectrophotometric method.  相似文献   

16.
The univariate and multivariate calibration methods were applied for the determination of trace amounts of palladium based on the catalytic effect on the reaction between resazurine and sulfide. The decrease in absorbance of resazurine at 602 nm over a fixed time is proportional to the concentration of palladium over the range of 10.0-160.0 ng mL(-1). The calibration matrix for partial least squares (PLS) regression was designed with 14 samples. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for PLS calibration without loss of prediction ability using spectrophotometric method. The root mean square error of prediction (RMSEP) for palladium determination with fixed-time, PLS and OSC-PLS were 3.71, 2.84 and 0.68, respectively. This procedure allows the determination of palladium in synthetic and real samples with good reliability of the determination.  相似文献   

17.
多元校正紫外光度法同时测定甲硝唑与维生素B6   总被引:2,自引:0,他引:2  
本文报道多元校正紫外光度法同时测定甲硝唑和维生素B6。首先在0.1mol/LHCl溶液中对甲硝唑和维生素B6两组分混合溶液进行分光光度法测定,然后将所得的重叠光谱数据经计算机采集后,分别用化学计量学方法中的偏最小二乘法(PLS)和主成分回归法(PCR)进行处理,并用于药物样品的测定,获得了较好的定量分析结果。该法甲硝唑和维生素B6的线性范围分别为1.0~28.0mg/L和1.0~28.0mg/L,检出限分别为0.568mg/L和0.364mg/L。  相似文献   

18.
19.
The multivariate calibration methods, partial least squares (PLS) and principle component regression (PCR) have been used to determine phenanthridine, phenanthridinone and phenanthridine N-oxide in spiked human plasma samples. Resolution of binary and ternary mixtures of analytes with minimum sample pre-treatment and without analyte separation has been successfully achieved analyzing the UV spectral data. The net analyte signal (NAS) concept was also used to calculate multivariate analytical figures of merit such as limit of detection, selectivity and sensitivity. The simultaneous determination of three analytes was possible by PLS and PCR processing of sample absorbance in the 210–355 nm region. Good recoveries were obtained for both synthetic mixtures and spiked human plasma samples.  相似文献   

20.
A novel method named OSC-WPT-PLS approach based on partial least squares (PLS) regression with orthogonal signal correction (OSC) and wavelet packet transform (WPT) as pre-processed tools was proposed for the simultaneous spectrophotometric determination of Al(III), Mn(II) and Co(II). This method combines the ideas of OSC and WPT with PLS regression for enhancing the ability of extracting characteristic information and the quality of regression. OSC is used to remove information in the response matrix D by subtracting the structured noise that is orthogonal to the concentration matrix C. Wavelet packet transform was applied to perform data compression, to extract relevant information, and to eliminate noise and collinearity. PLS was applied for multivariate calibration and noise reduction by eliminating the less important latent variables. In this case, using trials, the kind of wavelet function, the decomposition level, the number of OSC components and the number of PLS factors for the OSC-WPT-PLS method were selected as Daubechies 4, 3, 2 and 3, respectively. A program (POSCWPTPLS) was designed to perform the simultaneous spectrophotometric determination of Al(III), Mn(II) and Co(II). The relative standard errors of prediction (RSEP) obtained for total elements using OSC-WPT-PLS, WPT-PLS and PLS were compared. Experimental results demonstrated that the OSC-WPT-PLS method had the best performance among the three methods and was successful even when there was severe overlap of spectra.  相似文献   