首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
The potentialities of capillary ITP combined with diode‐array detection (DAD) with subsequent chemometric data processing have been investigated in this work. A series of different migration configurations were created using model analytes, interferents and appropriate spacers. Special attention has been paid not only to constituents migrating in fully developed ITP zones but also to the spike mode of ITP migration. The purity assessment and identity confirmation of model analytes migrating in both modes were performed by means of multivariate curve resolution and target transformation factor analysis (TTFA). Their successful applications have revealed a smart way to increase in the analytical information obtained by ITP separation even in the instance of trace analysis.  相似文献   

2.
Capillary isotachophoresis (ITP) was applied to the qualitative and quantitative analysis of both natural and synthetic oligo- and polypeptides. Based on the mathematical model of acid-base equilibria for a general ampholyte, a procedure and a computer program for the calculation of the pH dependence of the effective and specific charge and effective mobility of peptides with known amino acid sequence were developed which allow the selection of electrolyte systems for peptide isotachophoretic analysis to be rationalized. Basic peptides (bovine pancreatic trypsin inhibitor, bull seminal isoinhibitors of trypsin, arginine vasopressin and adamantylamide-alanylisoglutamine) were analysed with a cationic ITP system at acidic pH. Neutral and acidic peptides (insulin, proinsulin, bull seminal isoinhibitors of trypsin, cow colostrum isoinhibitors of trypsin) were analysed with an anionic ITP system, mostly at alkaline pH. Peptide purity (electrophoretic homogeneity) was determined from the ITP degree of purity defined by a peptide itself and the zone length ratio of its admixtures. Enrichment of peptide in the sample during the purification procedure was measured by its zone length relative to unit mass of the amount of sample analysed.  相似文献   

3.
Isotachophoretic (ITP) separation and determination of a group of 13 organic and inorganic acids, currently present in wines, on a poly(methyl methacrylate) chip provided with on-column conductivity detection was a subject of a detailed study performed in this work. Experiments with the ITP electrolyte systems proposed to the separation of anionic constituents present in wine revealed that their separation at a low pH (2.9) provides the best results in terms of the resolution. Using a 94 mm long separation channel of the chip, the acids could be resolved within 10-15 min also in instances when their concentrations corresponded to those at which they typically occur in wines. A procedure suitable to the ITP determination of organic acids responsible for some important organoleptic characteristics of wines (tartaric, lactic, malic and citric acids) was developed. Concentrations of 2-10 mg/l of these acids represented their limits of quantitation for a 0.9 microl volume sample loop on the chip. A maximum sample load on the chip, under the preferred separating conditions, was set by the resolution of malate and citrate. A complete resolution of these constituents in wine samples was reached when their molar concentration ratio was 20:1 or less. ITP analyses of a large series of model and wine samples on the chip showed that qualitative indices [RSH (relative step height) values] of the acids, based on the response of the conductivity detector, reproduced with RSD better than 2% while reproducibilities of the determination of the acids of our interest characterized RSD values better than 3.5%.  相似文献   

4.
This work reports on some methodological aspects of an off‐line combination of preparative ITP and HPLC with mass spectrometric detection (pITP‐HPLC‐MS) and its potential applications to the analysis of high molecular mass compounds present in complex biological matrices from the analytical chemistry perspective. Lysozyme served as the model analyte and human saliva as the complex biological matrix in this study. A mixture of five low‐molecular mass compounds was found and successfully used in the pITP experiments as discrete spacers to isolate the analyte from the interferents present in the complex biological matrix and to minimize their disturbance effect on the final MS analysis. The experiments at the pITP stage were performed in the cationic mode. On‐column conductivity detectors were used for the detection of ITP zones. Lysozyme was found in the human saliva samples using just deconvolution of the MS data after background correction. The MS data obtained from HPLC‐MS analysis of pITP fractions exhibited the great analytical potential of the combination of pITP‐HPLC‐MS resulting from the ITP clean‐up effect as well as the ITP preconcentration of the analyte present at low concentration levels in complex biological matrices.  相似文献   

5.
The analytical separation of proteins by isotachophoresis (ITP) was achieved in a short electrophoretic path and with a resolution comparable to that of isoelectric focusing by the appropriate selection of (1) a mixture of ampholytes as spacers to generate linear gradients of electrophoretic mobility and (2) the counter ions chosen to buffer the complete pH gradient generated. This ITP technique is exemplified by the analysis of plasma proteins in agarose gels. Up to 46 samples in the same gel plate were analysed. The resolution was such that at least 30 clear and discrete bands per sample could be observed after staining with Coomassie Brilliant Blue. The resolving power of ITP could be further increased for the study of a particular protein or zone by the selection of suitable spacers and counter ions.  相似文献   

6.
Summary The use of isotachophoretic sample pretreatment coupled with high performance liquid chromatography for the analysis of some flavonoids occurring in plant extracts of Hypericum perforatum and Crataegus sp. is described. The samples were extracted with methanol by means of sonication in low temperature. The optimal leading electrolyte was used 10 mM Cl as a leading ion in a buffer system at apparent pH*=7.2 (adjusted by TRIS) and terminating electrolyte was 50 mM boric acid at apparent pH*=8.2 (adjusted by barium hydroxide). The ITP electrolytes contained 20% (v/v) of methanol. To improve the sample pre-treatment, a pair of discrete ITP spacers defining the trapped constituents was used. Major components presented in the extracts were separated on a Discovery C18 and Discovery RP Amid C16 columns with a gradient mobile phase consisting of methanol, acetonitrile and diluted ortho-phosphoric acid. The quantification was performed by using external standards. The recoveries of the coupled ITP-HPLC analytical procedure were in the range of 91.2–95.6%.  相似文献   

7.
The use of carrier ampholyte-free IEF (CAF-IEF) with ITP mobilization and conductivity detection in ITP mode for preconcentration and analysis of amino acids is demonstrated. The analytical procedure consists of three subsequent steps. In the first step, amino acids are continuously dosed from an infinite volume reservoir by electromigration to the column, where a sharp, stationary neutralization reaction boundary (NRB) is created in between acidic and basic primary electrolyte. Here, amino acids are selectively focused (trapped), if their pI falls to the pH difference on both sides of the NRB (pH gap). Amino acids create sharp rectangular zones, arranged according to their pI values. In the second step, focused zones are mobilized. After accumulation of the detectable amount of amino acids, dosing electrolyte in the infinite volume reservoir is changed for the mobilizing electrolyte. The migration mode is changed from CAF-IEF to ITP and substances start to migrate toward the analytical capillary. In the third step, analytes are transferred into the analytical column equipped with a conductivity detector and are detected in the new leading electrolyte in an ITP migration mode. The presented CAF-IEF-ITP-ITP with time-dependent accumulation of the large-volume sample enables to achieve in a reasonable time a 100 times lower c-LOD (here in orders of nmol/L), than can be reached by conventional hyphenated ITP-ITP.  相似文献   

8.
This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.  相似文献   

9.
This contribution is the second part of the project on strategies used in the selection of electrolyte systems for anionic ITP with ESI‐mass spectrometric detection. It presents ITP as a powerful tool for selective stacking of anionic analytes, performed in a nonconventional way in moving‐boundary systems where two co‐anions are present in both the leading and terminating zones. The theoretical background is given to substantiate the conditions for the existence and migration of ITP boundaries in moving‐boundary systems and stacking of analytes at these boundaries. The practical aspects of the theory are shown in form of stacking‐window diagrams that bring immediate information about which analytes are stacked in a given system. The presented theory and strategy are illustrated and verified on the example of analysis of a model mixture of salicylic acid, ibuprofen and diclofenac, and comparison of regular and free‐acid ITP with moving‐boundary ITP systems formed by formic and propionic acids and ammonium as counterion.  相似文献   

10.
This feasibility study deals with the separations of proteins by an on-line combination of zone electrophoresis (ZE) with isotachophoresis (ITP) on a poly(methylmethacrylate) column-coupling (CC) chip with integrated conductivity detection. ITP and ZE provided specific analytical functions while performing the cationic mode of the separation. ITP served, mainly, for concentrations of proteins and its concentrating power was beneficial in reaching a low dispersion transfer (injection) of the proteinous constituents, loaded on the CC chip in a 960 nL volume, into the ZE separation stage. This was complemented by an electrophoretically driven removal of the sample constituents migrating in front of the focused proteins from the separation system before the ZE separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions providing the resolutions and sensitive conductivity detections of the test proteins. In this way, ITP and ZE cooperatively contributed to low- or sub-microg/mL concentration detectabilities of proteins and their quantitations at 1-5 microg/mL concentrations. However, a full benefit in concentration detectabilities of proteins, expected from the use of the ITP-ZE combination, was not reached in this work. Small adsorption losses of proteins and detection disturbances in the ZE stage of separation, very likely due to trace constituents concentrated by ITP, appear to set limits in the detection of proteins in our experiments. The ITP-ZE separations were carried out in a hydrodynamically closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows of the electrolyte solutions. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, undoubtedly contributed to highly reproducible migrations of the separated proteins (fluctuations of the migration time of a particular protein were typically 0.5% RSD in repeated ITP-ZE runs).  相似文献   

11.
A capillary electroseparation technique for focusing and selective pre-concentration of metal chelates with subsequent on-line isotachophoresis (ITP) analysis was developed and verified. The ions of alkali earth metals (Mg, Ca, Sr, and Ba) were pre-concentrated from the mixture and analyzed. The focusing of the metals was carried out in a ligand step gradient, which was created by the addition of a convenient ligand agent to the regular stationary pH step gradient. The analytical procedure consisted of three steps. During the first step, the metal ions were electrokinetically continuously dosed into the column where they were selectively trapped on the stationary ligand step gradient in the form of unmoving zones of chelate complexes with effectively zero charge. After a detectable amount of analyte was accumulated, the dosing was stopped. The accumulated zones were mobilized to the analytical column, where they were analyzed by the ITP method with conductivity or photometric detection. The proper electrolyte systems for dosing, mobilizing, and analyzing in isoelectric focusing (IEF), moving boundary electrophoresis (MBE), and ITP modes were consequently developed and put into practice. The trapping selectivity can be regulated by the choice of pH and convenient complexing agents. A mixture of alkali earth metals were used as model analytes. Using a 3000 s dosing time, the proposed method improved the detection limit by 5-29 times in comparison to analysis by ITP with classical injection.  相似文献   

12.
The use of preparative capillary isotachophoresis (CITP), operating in a discontinuous fractionation mode, for separation and fast purification of the enzyme uridine diphosphate galactopyranose mutase (UGM) from the cell extract of Escherichia coli overproducing the recombinant enzyme is presented in this feasibility study. UGM is required to produce galactofuranose for the cell wall biosynthesis of many pathogenic microorganisms and represents a very attractive candidate for the development of new antimicrobial drugs. CITP separations were carried out under slightly alkaline pH conditions (8.7), in which UGM enzyme is negatively charged. Significantly simplified proteinous matrix isolated in several fractions by employed preparative CITP procedure with the aid of properly selected discrete spacers was subsequently confirmed by SDS PAGE with Coomassie staining. It was shown that preparative CITP is very effective tool for fast purification of the target enzyme from other proteinous matrix constituents when purification and isolation step lasted 20 min. The enzymatic activity of UGM was confirmed in the sample after the preparative CITP purification step, which is a crucial requirement for further biochemical applications.  相似文献   

13.
R Vespalec  P Gebauer  P Bocek 《Electrophoresis》1992,13(9-10):677-682
A procedure is proposed for the calculation of the actual effective mobility of a zone from its migration time. It is based on the use of internal standards with known mobilities; the use of two internal standards provides reliable mobility data even if the magnitudes of the effects of sample composition, capillary temperature, capillary length, migration distance, used voltage, as well as the tube length occupied by the injected sample are unknown. Formulas have been derived for the calculation of the actual mobilities, and their experimental verification has been carried out by using a model set of anionic solutes with mobilities ranging from -56 to -20 x 10(-9) m2V-1s-1 and chloride as the ion modelling the effect of the sample matrix.  相似文献   

14.
Hirokawa T  Takayama Y  Arai A  Xu Z 《Electrophoresis》2008,29(9):1829-1835
Aiming to achieve high-performance analysis of DNA fragments using microchip electrophoresis, we developed a novel sample injection method, which was given the name of floating electrokinetic supercharging (FEKS). In the method, electrokinetic injection (EKI) and ITP preconcentration of samples was performed in a separation channel, connecting two reservoir ports (P3 and P4) on a cross-geometry microchip. At these two stages, side channels, crossing the separation channel, and their ports (P1 and P2) were electrically floated. After the ITP-stacked zones passed the cross-part, they were eluted for detection by using leading ions from P1 and P2 that enabled electrophoresis mode changing rapidly from ITP to zone electrophoresis (ZE). Possible sample leakage at the cross-part toward P1 and P2 was studied in detail on the basis of computer simulation using a CFD-ACE+ software and real experiments, through which it was validated that the analyte recovery to the separation channel was almost complete. The FEKS method successfully contributed to higher resolution and shorter analysis time of DNA fragments on the cross-microchip owing to more rapid switching from ITP status to ZE separation in comparison with our previous EKS procedure realized on a single-channel microchip. Without any degradation of resolution, the achieved LODs were on average ten times better than using conventional pinched injection.  相似文献   

15.
The purpose of applying a countercurrent flow to isotachophoretic migration is to increase the effective separation channel length during ITP. However, severe dispersion induced by applying a counterflow can be detrimental to ITP. This paper uses numerical simulations in a 2D axisymmetric domain to investigate the dispersion caused by a parabolic counterflow in open‐capillary ITP. Counterflow in these simulations was generated by applying a back pressure to stop the isotachophoretic stack, i.e., forming stationary ITP zones. It is found that dispersion is strongly related to analyte molecular diffusivity: R‐phycoerythrin, due to its small diffusivity, showed ~20‐fold increase in zone width in stationary counterflow ITP, compared to ITP in the absence of counterflow, while fluorescein only had ~10% increase in zone width under similar operating conditions. Applying the Taylor–Aris dispersion formula in counterflow ITP simulations provided only a rough estimate of the dispersion, e.g., overestimation of analyte zone widths. Experiments on counterflow ITP were conducted in a silica capillary that was covalently and dynamically coated to exclude electroosmosis effect. The counterflow was generated by adjusting the relative height of the fluids in the two reservoirs at the capillary ends. Good qualitative agreement between simulations and experiments was found.  相似文献   

16.
The ability of capillary zone electrophoresis (CZE) coupled on‐line with capillary isotachophoresis (ITP) sample pretreatment in the column‐coupling capillary electrophoresis equipment to separate trace enantiomers present in samples of complex ionic matrices and enantiomers present in their mixtures at significantly differing concentrations has been studied. Enantiomers of 2,4‐dinitrophenyl labeled norleucine (DNP‐Nleu) and tryptophan enantiomers were employed as model analytes in this work while urine and mixtures of tryptophan enantiomers of differing concentrations served as model samples. Experiments performed with urine samples spiked with the DNP‐Nleu racemate at sub‐μmol/L concentrations demonstrated excellent sample pretreatment capabilities of ITP (concentration of the analytes, in‐column and post‐column sample clean up) when coupled on‐line with chiral CZE separations. In the CZE separations of enantiomers present in the samples at trace concentrations the sample pretreatment could be performed in both achiral and chiral ITP electrolyte systems. The use of a chiral electrolyte system was found to be essential in the ITP pretreatment of the samples containing the enantiomers at very differing concentrations. For example, a 2×10–7 mol/L concentration of L‐tryptophan could be detected in the CZE separation stage of the ITP‐CZE combination in samples containing about a 104 excess of D‐tryptophan only when the ITP pretreatment was carried out in the electrolyte system providing the resolution of enantiomers (α‐cyclodextrin served for this purpose in the present work). A post‐column ITP sample clean up was found effective in enhancing the destacking rate of the trace enantiomer in the CZE stage when the migration configuration of the enantiomers was less favorable (the trace constituent migrating behind the major enantiomer).  相似文献   

17.
The present work illustrated possibilities of column coupling electrophoresis combined with ionizable chiral selector and diode array detection (DAD) for the enantioselective analysis of trace drugs (pheniramine and its analogs) in pharmaceutical and clinical samples. Isotachophoresis (ITP), on-line coupled with capillary zone electrophoresis (CZE), served as an ideal injection technique (high sample load capacity, narrow and sharp drugs zones) of on-line pretreated samples (preseparation, purification and preconcentration of drugs) for the CZE stage. Enhanced (enantio)separation selectivity of CZE with ionizable chiral selector (carboxyethyl-beta-cyclodextrin recognized between drugs enantiomers on one hand as well as between drugs and sample matrix constituents on the other hand) enabled to obtain pure zones of the drugs enantiomers, suitable for their detection and quantitation. DAD in comparison with single wavelength UV detection enhanced value of analytical information verifying purity of drugs enantiomers zones (indicating interferents with different spectra to those of drugs). Obtained results indicated pure zones of interest confirming effective ITP-CZE (enantio)separation process. Distinguishing the trace analytes signals superposed on the baseline noise was provided with sufficient reliability (for this purpose the background correction and smoothing procedure had to be applied to the raw DAD spectra). The proposed ITP-CZE-DAD methods were characterized by favorable performance parameters (sensitivity, linearity, precision, recovery, accuracy, robustness, selectivity) and successfully applied for (i) enantiomeric purity testing of dexbrompheniramine in commercial pharmaceutical tablets and (ii) enantioselective metabolic study of pheniramine in human urine.  相似文献   

18.
Beckers JL 《Electrophoresis》2000,21(14):2788-2796
A sample stacking procedure to which a specific combination of electrolyte solutions is applied is isotachophoresis (ITP) superimposed on capillary zone electrophoresis (CZE), a so-called ITP/CZE system. In ITP/CZE some components migrate in an ITP fashion on top of a background electrolyte, and the other analytes migrate in a zone electrophoretic manner. For such a system, the leading electrolyte consists of a mixture of an ionic species, L1, of high mobility (the leading ion of the ITP system), an ionic species, L2, of low mobility (the coions of the CZE system), and a buffering counter-ionic species, whereas the terminating solution only contains the ionic species L2 and the buffering counterions. The zones of the components migrating in the ITP/CZE mode are sharp owing to the self-correcting properties of the zones and the concentrations of the L1 ions of the system. Mobility windows can be calculated, indicating which ions can migrate in the ITP/CZE mode. In this article mobility windows are calculated by applying both strong and weak acids as L1 and L2 ions and it appears that mobility windows can be optimized by chosing different ratios of L1 and L2 as well as different pH values. It is possible to construct very narrow mobility windows, and thereby choose which component of a sample solution can be concentrated, and to what concentration, in a very selective way. The big advantage of ITP/CZE compared with applications such as transient ITP and transient stacking is that the stacked sample ionic species migrate in the ITP mode during the whole experiment; furthermore, they do not destack. Experimentally obtained electropherograms validate the calculated mobility windows for the ITP/CZE mode.  相似文献   

19.
A macroporous carbon sorbent, packed into disposable columns (Separcol-Carb), was investigated for the off-line preconcentration of short-chain fatty acids from drinking water in conjunction with their determination by capillary isotachophoresis (ITP). Of the acids investigated (C1-C9), butyric acid and higher homologues could be enriched into a high degree from samples of drinking water. Their detection limits from the ITP conductivity detector were in the low parts per 10(9) range when an amount equivalent to 8 ml of the sample was taken for analysis. The lowest homologues (C1-C3) were not adsorbed sufficiently to achieve their reasonable enrichment by the sorbent under the working conditions employed (acidification of the sample to pH 2.0). Acetone and diethyl ether were employed for the elution of the adsorbed analytes. The latter was more convenient in the analysis of practical samples as it co-eluted a considerably smaller number of the adsorbed anionic constituents. Octadecyl-bonded silica, evaluated in parallel, was found to be of only very limited utility for the same purpose.  相似文献   

20.
In this paper, we suggest new electrolyte system for fast preparative electrofocusing in wide pH range. It is based on bidirectional ITP with multiple counterions and spacers created by commercially available defined simple buffers. The migration course of proposed focusing model can be simulated in advance by using separation conditions and electrolyte components that are consequently applied during the experiments. The suggested electrolyte system allows high current densities at the initial stages of focusing without danger of local overheating, which strongly reduces the time needed for analysis completion. The performance of the electrolyte system is demonstrated by the focusing of synthetic colored low molecular weight indicators and proteins in the arrangements with both linear narrow strip and nonwoven fabric sheet with continuous flow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号