首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Rao BV  Gopinath R 《Talanta》1989,36(8):867-868
A simple potentiometric method is presented for successive determination of iron(III) and cobalt(II) by complexometric titration of the iron(III) with EDTA at pH 2 and 40 degrees , followed by redox titration of the cobalt(II) complex with 1,10-phenanthroline or 2,2'-bipyridyl at pH 4-5 and 40 degrees , with gold(III). There is no interference in either determination from common metal ions other than copper(II), which severely affects the cobalt determination but can be removed by electrolysis. The method has been successfully applied to determination of iron and cobalt in Kovar and Alnico magnet alloys.  相似文献   

2.
Enthalpimetric and potentiometric titrations of 2-hydroxy-5-methyl-4′-methoxy chalkone oxime (HMMCO), 2-hydroxy-5-chloro-4′-methoxy chalkone oxime (HCMCO), and 2-hydroxy-3-bromo-5-methyl-4′-methoxy chalkone oxime (HBMMCO) were carried in acetone medium using tetra-n-butyl ammonium hydroxide, potassium hydroxide in isopropyl alcohol, and potassium tertiary butoxide in tertiary butyl alcohol, as titrants. Alcoholic KOH was found to be the most suitable titrant. Enthalpimetric titrations could be used for 1–8 mg of oximes where as potentiometric titrations gave accurate results for 1–20 mg.  相似文献   

3.
The acid–base properties of analogous complex ions of chromium(III) and cobalt(III) in aqueous solution have been studied. The equilibrium constants for all metal complexes were determined by using potentiometric and spectrophotometric titration methods. First, dissociation constants for the studied complexes of Cr(III) and Co(III) were determined by means of the potentiometric titration method and using the STOICHIO computer programme. Then, pH-spectrophotometric titrations were performed and the OriginPro 7.5 computer programme was used to calculate the same constants. The measurements using both methods were carried out under the same conditions of temperature, T = 298.15 K, and over the same pH range 2.00–10.00, respectively. It turned out that the two methods used enabled us to obtain acidity constants in very good agreement.  相似文献   

4.
Hexacyanoferrate(II)-sensing electrodes were prepared by mixing Ag2S and Ag4Fe (CN)6. The 6:1 Ag2S/Ag4Fe (CN)6 provided the best potentiometric response and speed of response. The log concentration vs. potential curves were linear with Nernstian slope (14.8 mV/decade) over the range 10?1-10?6 M hexacyanoferrate (II) at pH 7.00 with constant ionic strength. Interferences included iodide, sulfide and bromide. This electrode was used as indicator in potentiometric titrations of hexacyanoferrate (II).  相似文献   

5.
A new heterogeneous precipitate of an organic-inorganic composite cation-exchanger poly-o-toluidine Zr(IV) phosphate was utilized for the preparation of a Hg(II) ion-sensitive membrane electrode for the determination of Hg(II) ions in real aqueous as well as in real samples. The electrode showed good potentiometric response characteristics, and displayed a linear log[Hg(2+)] versus EMF response over a wide concentration range of 1 x 10(-1) - 1 x 10(-6) M with a Nernstian slope of 30 mV per decade change in concentration with a detection limit of 1 x 10(-6). The membrane electrode showed a very fast response time of 5 s and could be operated well in the pH range 2 - 8. The selectivity coefficients were determined by the mixed-solution method, and revealed that the electrode was selective in the presence of interfering cations; however most of these did not show significant interference in the concentration range of 1 x 10(-1) - 1 x 10(-4) M. The lifetime of the membrane electrode was observed to be 120 days. The analytical utility of this electrode was established by employing it as an indicator electrode in the potentiometric titrations of Hg(2+) ions from a synthetic mixture as well as drain water.  相似文献   

6.
The electronic absorption spectra of 2-(2-hydroxynaphthylazo)-4-hydroxy-6-methyl-1,3-pyrimidine in pure organic solvents of different polarities and in buffer solutions of varying pH are studied. The important bands in the IR and the main signals in the (1)H NMR spectra are assigned. The observed UV-vis absorption bands are assigned to the corresponding electronic transitions. The molecular stoichiometry, stability constant, absorption maximum, molar absorptivity and Sandell's sensitivity of the complexes are calculated. Obeyence to Beer's law and Ringbom optimum concentration ranges are also determined. The ability of using the titled azodye as metalochromic indicator in complexometric titrations was also studied. The effect of Co(II), Ni(II) and Cu(II) ions on the fluorescence of the azodye is also considered. The solid Cu(II) complexes of the titled azodye have been prepared and characterized by elemental, IR, UV-vis spectra as well as by conductometric and magnetic measurements. The data suggest square planar geometry for 1:1 and 1:2 (M:L) complexes. The thermal behaviour of the complexes has been studied. The kinetic parameters (n, E, A, deltaH, DeltaS and deltaG) of the thermal decomposition steps are computed using Coats-Redfern equations.  相似文献   

7.
The pH dependence of the complexes was determined by both potentiometric and spectrophotometric studies. Stability constants and stoichiometries of the formed complexes were determined using slope ratio method. Fe(III) was formed complexes with tannic acid of various stoichiometries, which in the 1:1 molar ratio at pH<3, in the 2:1 molar ratio at pH 3-7 and in the 4:1 molar ratio at pH>7. Fe(III) was formed complexes with myricetin in the 1:2 molar ratio at pH 4 and 5 and in the 1:1 molar ratio at pH 6. Stability constant values were found to be 10(5) to 10(17) and 10(5) to 10(9) for Fe(III)-tannic acid complexes and Fe(III)-myricetin complexes. Both tannic acid and myricetin were possessed minimum affinities to Cu(II) and Zn(II). They had less affinity for Al(III) than for Fe(III).  相似文献   

8.
Ti/TiO2 indicator electrodes were prepared by plasma electrolytic oxidation (PEO) method in the tetraborate electrolyte and were used for potentiometric indication of chemical reactions of different types and for analysis of surface and industrial wastewaters on the example of potentiometric determination of alkalinity and chloride. The electrodes formed at current densities of 0.05, 0.1, 0.15 and 0.2 A/cm2 are different in composition, surface morphology and electroanalytical properties. The electrodes formed at a current density of 0.05 A/cm2 exhibit the highest pH-sensitivity and generate the highest analytical signal at the equivalence point in the acid–base and precipitation titrations. The maximum analytical signal at the equivalence point, exceeding in magnitude the analytical signal, obtained by classical Pt electrode in oxidation–reduction and complexometric titrations generates PEO layers formed at a current density of 0.05 A/cm2 and a platinum-modified nanoparticles. The results of the potentiometric titration of the surface and technogenic waters using as indicator Ti/TiO2 electrodes are comparable with the conventionally used glass electrode (to determine alkalinity) and Ag electrode (to the determine chloride) and the results of visual titration. The advantage of the obtained metal oxide systems is the ability to determine two hydrochemical parameters due to their multifunctionality and opportunity to work with a single electrode. In addition, these sensors offer some analytical characteristics such as sensitivity, good reproducibility, high mechanical stability and a simple preparation procedure.  相似文献   

9.
Iron chelates such as ethylenediamine-N,N'-bis(2-hydroxyphenyl)acetic acid (EDDHA) and their analogues are the most efficient soil fertilizers to treat iron chlorosis in plants growing in calcareous soils. EDDHA, EDDH4MA (ethylenediamine-N,N'-bis(2-hydroxy-4-methylphenyl)acetic acid), and EDDCHA (ethylenediamine-N,N'-bis(2-hydroxy-5-carboxyphenyl)acetic acid) are allowed by the European directive, but also EDDHSA (ethylenediamine-N,N'-bis(2-hydroxy-5-sulfonylphenyl)acetic acid) and EDDH5MA (ethylenediamine-N,N'-bis(2-hydroxy-5-methylphenyl)acetic acid) are present in several commercial iron chelates. In this study, these chelating agents as well as p,p-EDDHA (ethylenediamine-N,N'-bis(4-hydroxyphenyl)acetic acid) and EDDMtxA (ethylenediamine-N,N'-bis(2-metoxyphenyl)acetic acid) have been obtained following a new synthetic pathway. Their chemical behavior has been studied to predict the effect of the substituents in the benzene ring on their efficacy as iron fertilizers for soils above pH 7. The purity of the chelating agents has been determined using a novel methodology through spectrophotometric titration at 480 nm with Fe(3+) as titrant to evaluate the inorganic impurities. The protonation constants were determined by both spectrophotometric and potentiometric methods, and Ca(2+) and Mg(2+) stability constants were determined from potentiometric titrations. To establish the Fe(3+) and Cu(2+) stability constants, a new spectrophotometric method has been developed, and the results were compared with those reported in the literature for EDDHA and EDDHMA and their meso- and rac-isomers. pM values have been also determined to provide a comparable basis to establish the relative chelating ability of these ligands. The purity obtained for the ligands is higher than 87% in all cases and is comparable with that obtained by (1)H NMR. No significant differences have been found among ligands when their protonation and stability constants were compared. As expected, no Fe(3+) complexation was observed for p,p-EDDHA and EDDMtxA. The presence of sulfonium groups in EDDHSA produces an increase in acidity that affects their protonation and stability constants, although the pFe values suggest that EDDHSA could be also effective to correct iron chlorosis in plants.  相似文献   

10.
The construction and the application of a silica gel based carbon-epoxy indicator electrode for the potentiometric determination of acids and bases are described. The effect of composition of silica gel and carbon-epoxy, slope (mV/pH), linear response (pH range) and the use for acid-base titrations were investigated. The data obtained for the acid-base titrations were compared with those obtained using a glass electrode in the same conditions. The electrode showed a linear response in the pH 2 to 13 range with a slope of –40.5 ± 0.4 mV/pH (at 25 °C) and a response time of less than 15 s. The lifetime of the electrode was higher than one year (over 6000 determinations) with a decrease of only 5% of the initial potentiometric response. The silica gel based carbon-epoxy electrode showed excellent results in the end-point indication potentiometric titrations in determination of acids and bases. The miniaturization of the proposed electrode for flow injection analysis was investigated. Received: 11 August 1999 / Revised: 4 October 1999 / Accepted: 7 October 1999  相似文献   

11.
Parczewski A 《Talanta》1987,34(6):586-588
It has been proved that application of two indicator electrodes connected to the ordinary titration apparatus through an auxiliary electronic device (a summing operational amplifier) significantly extends the scope of multicomponent potentiometric titrations in which the analytes are determined simultaneously from a single titration curve. For each analyte there is a corresponding potential jump on the titration curve. By application of the proposed auxiliary device, the sum of the electrode potentials is measured. The device also enables the relative sizes of the potential jumps at the end-points on the titration curve to be varied. The advantages of the proposed signal processing are exemplified by complexometric potentiometric titrations of Fe(III) and Cu(II) in mixtures, with a platinum electrode and a copper ion-selective electrode as the indicator electrodes.  相似文献   

12.
The behaviour of a new type of electrode, made from ceramic Ag(2)S, has been investigated. The electrode response is Nernstian for Ag(+) over the range 10(-6)-2M and for Hg(2+) in the concentration range 10(-6)-10(-2)M, both at constant ionic strength (0.1M). The electrode is Ag(+)-selective, with maximum interference from Hg(2+). It can be used for acid-base potentiometric titration and for potentiometric Ag(+) and Hg(2+) precipitation titrations.  相似文献   

13.
The construction and the application of a silica gel based carbon-epoxy indicator electrode for the potentiometric determination of acids and bases are described. The effect of composition of silica gel and carbon-epoxy, slope (mV/pH), linear response (pH range) and the use for acid-base titrations were investigated. The data obtained for the acid-base titrations were compared with those obtained using a glass electrode in the same conditions. The electrode showed a linear response in the pH 2 to 13 range with a slope of -40.5 +/- 0.4 mV/pH (at 25 degrees C) and a response time of less than 15 s. The lifetime of the electrode was higher than one year (over 6000 determinations) with a decrease of only 5% of the initial potentiometric response. The silica gel based carbon-epoxy electrode showed excellent results in the end-point indication potentiometric titrations in determination of acids and bases. The miniaturization of the proposed electrode for flow injection analysis was investigated.  相似文献   

14.
U(VI) sorption on kaolinite was studied as functions of contact time, pH, U(VI) concentration, solid-to-liquid ratio (m/V) by using a batch experimental method. The effects of sulfate and phosphate on U(VI) sorption were also investigated. It was found that the sorption kinetics of U(VI) can be described by a pseudo-second-order model. Potentiometric titrations at variable ionic strengths indicated that the titration curves of kaolinite were not sensitive to ionic strength, and that the pH of the zero net proton charge (pHPZNPC) was at 6.9. The sorption of U(VI) on kaolinite increased with pH up to 6.5 and reached a plateau at pH >6.5. The presence of phosphate strongly increased U(VI) sorption especially at pH <5.5, which may be due to formation of ternary surface complexes involving phosphate. In contrast, the presence of sulfate did not cause any apparent effect on U(VI) sorption. A double layer model was used to interpret both results of potentiometric titrations and U(VI) sorption on kaolinite.  相似文献   

15.
Dithiodibenzoic (DTB) acid and mercaptobenzoic (MB) acid were studied to characterize their abilities as modifier agents for lead(II) sensors. For both sensors, the best results were obtained with modified carbon paste electrodes with 24.1% of ligand. The pH influence on the potentiometric response was studied. The selectivity coefficients for both modified electrodes were tabulated. A potentiometric sensor based on DTB acid exhibited a more sensitive and selective response to lead ions than an MB electrode. The limits of detection for the DTB and MB electrodes were very similar, 5.01 x 10(-8) M and 3.98 x 10(-8) M, respectively, for lead(II) activity. The DTB sensor was applied to lead(II) ion determination in real samples and as an indicator electrode in potentiometric titrations. Natural and commercial humic acids were titrated using the DTB electrode to estimate the stability constant between these organic compounds and the lead(II) ions with successful results.  相似文献   

16.
Johansson A 《Talanta》1974,21(12):1269-1280
A titration apparatus plotting either the concentration of sample ion or the concentration of titrant ion has been tested. An antilog apparatus, converting measured e.m.f. values into concentrations is connected to ordinary titration equipment. The instrument has been tested by means of acid—base titrations (titrations of mixtures of weak acids and of a weak and a strong acid), precipitation titrations (determination of the chloride concentration in tap-water, titration of mixtures of halides), titrations with ion-selective electrodes (determination of the fluoride content of toothpaste) and complexometric titrations (determination of copper with EDTA, using mercuric ion as indicator ion and amalgamated silver rod as indicator electrode, or using a copper-selective indicator electrode). The method considerably simplifies the evaluation of the results as compared to conventional potentiometric titrations.  相似文献   

17.
提出一种以亚甲基二膦酸(MDPA, H4L)为主配位剂的无氰镀铜体系. 采用pH 电位滴定法分别测定MDPA的四级解离常数和MDPA-Cu(II)的稳定常数, 并比较MDPA-Cu(II)和羟基乙叉二膦酸(HEDPA)-Cu(II)的循环伏安曲线和阴极极化曲线. 结果表明: MDPA各级解离常数为, pK1=1.86, pK2=2.65, pK3=6.81, pK4=9.04;MDPA与Cu2+形成分级配合物的稳定常数为, pKML=10.65, pKML2 = 5.59, pKML3 = 2.50; 随着pH升高, 形成的配合物依次为, Cu(H3L)2、[Cu(H3L)(H2L)]-和[Cu(H2L)2]2-; 当pH在7-10 时, MDPA较HEDPA更易与Cu2+配位. 当pH=9 时, MDPA碱性镀铜体系阴极主要发生的是[Cu(H3L)(H2L)]-和[Cu(H2L)2]2-还原生成铜的过程; 在10 °C,MDPA体系的铜配位化合物还原生成铜的电位比HEDPA体系负移, 扩散速度更快.  相似文献   

18.
Gholivand MB  Mozaffari Y 《Talanta》2003,59(2):399-407
A PVC membrane electrode based on bis(2-nitrophenyl)disulfide carrier exhibits a very good response for Zn2+ in a wide concentration range (from 2.9×10−7 to 3.2×10−2 mol l−1) with a slope of 29.9±0.4 mV per decade of Zn2+ concentration. The response time of the sensor is about 10 s and the membrane can be used for more than 3 months without any observed divergence in potentials. The proposed sensor exhibits very good selectivity for Zn2+ over many cations and can be used in a wide pH range (2-9). This assembly served also as an indicator electrode in potentiometric titrations involving zinc ions and direct potentiometric determination of zinc ions in real and synthetic samples.  相似文献   

19.
Hassan SS  Abbas MN  Moustafa GA 《Talanta》1996,43(5):797-804
A novel potentiometric Cr(6+) PVC matrix membrane sensor incorporating nickel tris(1,10-bathophenanthroline) hydrogen chromate as an electroactive material and 2-nitrophenyl phenyl ether as solvent mediator is described. In a phosphate buffer solution of pH 5, the sensor displays a rapid and linear response for Cr(6-) over the concentration range 2 x 10(-2)-8 x 10(-6) M with an anionic slope of 55.5 +/- 0.2 mV decade(-1) and a detection limit of the order of 0.4 microg ml(-1). The sensor is used for sequential determination of Cr(6+) and Cr(3+) by direct monitoring of Cr(6+) followed by oxidation of Cr(3+) and measurement of the total chromium. The average recoveries of Cr(3+) and Cr(6+) at concentration levels of 0.5-50 microg ml(-1) are 98.1 +/- 0.4% and 99.1 +/- 0.4% respectively. Redox and precipitation titrations involving Cr(6+) as a titrant are monitored with the sensor. Cr(3+) and/or Cr(6+) in wastewaters of some industries (e.g., leather tanning, electroplating, aluminum painting) and the chromium contents of some alloys and refractory bricks are assessed. The results agree fairly well with data obtained using the standard diphenylcarbazide spectrophotometric method.  相似文献   

20.
[structure in text] The pK(a) values and the geometries of secondary and tertiary amines adjacent to boronic acids were determined using potentiometric and (11)B NMR titrations. The studies showed that the secondary ammonium ion has a pK(a) similar to that of the tertiary ammonium species, which leads to the formation of tetrahedral boron centers at pH values above approximately 5.5. Therefore, secondary amines as well as tertiary amines, when placed proximal to boron centers, can be used to create tetrahedral boronic acids at neutral pH for diol complexation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号