首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A porous and highly efficient polyaniline‐based solid‐phase microextraction (SPME) coating was successfully prepared by the electrochemical deposition method. A method based on headspace SPME followed by HPLC was established to rapidly determine trace chlorophenols in water samples. Influential parameters for the SPME, including extraction mode, extraction temperature and time, pH and ionic strength procedures, were investigated intensively. Under the optimized conditions, the proposed method was linear in the range of 0.5–200 μg/L for 4‐chlorophenol and 2,4,6‐trichlorophenol, 0.2–200 μg/L for 2,4‐dichlorophenol and 2–200 μg/L for 2,3,4,6‐tetrachlorophenol and pentachlorophenol, with satisfactory correlation coefficients (>0.99). RSDs were <15% (n = 5) and LODs were relatively low (0.10–0.50 μg/L). Compared to commercial 85 μm polyacrylate and 60 μm polydimethylsiloxane/divinylbenzene fibers, the homemade polyaniline fiber showed a higher extraction efficiency. The proposed method has been successfully applied to the determination of chlorophenols in water samples with satisfactory recoveries.  相似文献   

2.
An aniline-based polymer was electrochemically prepared and applied as a new fiber coating for solid phase microextraction (SPME) of some priority phenols from water samples. The polyaniline (PANI) film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The efficiency of new coating was investigated using a laboratory-made SPME device and gas chromatography with flame ionization detection for the extraction of some phenols from the headspace of aqueous samples. The scanning electron microscopy (SEM) images showed the homogeneity and the porous surface structure of the film. The results obtained proved the ability of this polymer as a suitable SPME fiber coating for trapping the selected phenols. Influential parameters affecting the extraction process were optimized and an extraction time of 50 min at 50 °C gave maximum efficiency, when the aqueous sample was saturated with NaCl and adjusted at pH 2. This new coating can be prepared easily in a reproducible manner and it is rather inexpensive and stable against most of organic solvents. The PANI thickness can be precisely controlled by the number of CV cycles. At the optimum conditions, the R.S.D. for a double distilled water spiked with phenol and chlorophenols at ppb level were 4.8-17% (n = 3) and detection limits for the studied compounds were between 0.69 and 3.7 ng ml−1, except for phenol and 4-chlorophenol. The optimized method was successfully applied to some real-life water samples.  相似文献   

3.
A high-temperature-resistant solid-phase microextraction (SPME) fiber was prepared based on polyetherimide (PEI) by the electrospinning method. The PEI polymeric solution was converted to nanofibers using high voltages and directly coated on a stainless steel SPME needle. The scanning electron microscopy images of PEI coating showed fibers with diameter range of 500–650 nm with a homogeneous and smooth surface morphology. The SPME nanofibers coating was optimized for PEI percentage, electrospinning voltage, and time. The extraction efficiency of the coating was investigated for headspace SPME of some environmentally important polycyclic aromatic hydrocarbons from aqueous samples followed by gas chromatography–mass spectrometry measurement. In addition, the important extraction parameters including extraction temperature, extraction time, ionic strength, as well as desorption temperature and time were investigated and optimized. The detection limits of the method under optimized conditions ranged from 1 to 5 ng L?1 using time-scheduled selected ion monitoring mode. The relative standard deviations of the method were between 1.1 and 7.1 %, at a concentration level of 500 ng L?1. The calibration curves of polycyclic aromatic hydrocarbons showed linearity in the range of 5–1000 ng L?1. The developed method was successfully applied to real water samples and the relative recovery percentages obtained from the spiked water samples were from 84 to 98 % for all the selected analytes except for acenaphthene which was from 75 to 106 %.  相似文献   

4.
《Analytical letters》2012,45(16):2477-2486
A novel solid-phase microextraction (SPME) fiber was prepared by coating multiwalled carbon nanotube (MWCNTs) on a stainless steel wire, and its characteristics were studied. To evaluate the MWCNTs coating, the fiber was used for the extraction of some organochlorine pesticides (OCPs) from water samples by Headspace SPME (HS-SPME) mode. Potential factors affecting the extraction efficiency such as extraction time, extraction temperature, agitation, ionic strength, desorption temperature, and time were also optimized. Several experiments were carried out by water spiked with target compounds to evaluate the analytical characteristics of the proposed method under optimized conditions. The linearity was from 0.1 to 10 ug/L with the linear correlation coefficients (r) ranging from 0.9956 to 0.9995. The limits of detection (LOD, S/N = 3) for these pesticides were between 0.43 and 2.13 ng/L and the precision (RSD, n = 5) was 2.53–12.25%. When this method was applied for the spiked real river sample, the relative recoveries ranged from 72.4% to 134.7% for the tested OCPs.  相似文献   

5.
This work is a first study on extraction efficiency and thermal stability of nano-structured self-doped polyaniline (SPAN) as a coating of solid-phase microextraction (SPME) fibers. SPAN-based fibers were prepared using electrochemical deposition on platinum wires. The particle sizes of prepared nano-structure were in the range of 50–100 nm. Extraction properties of the fiber to 1,4-dioxane were examined using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-flame ionization detection (GC-FID). The results have proved higher thermal stability of the proposed fiber compared to common PANI fiber. The SPAN coating was proved to be very stable at relatively high temperatures (up to 350 °C) with high extraction capacity and long lifespan (more than 50 times). Therefore, it can be a good substitute of polyaniline (PANI) as a SPME coating. The extraction procedure was optimized by selecting the appropriate extraction parameters including extraction time, extraction temperature, salt concentration, stirring rate and headspace volume. Calibration graph was linear in the concentration range of 1–100 ng mL−1 (R2 > 0.993) with detection limit of 0.1 ng mL−1. Single fiber and fiber-to-fiber repeatability were lower than 6.0% and 10.4%, respectively. Different water samples were analyzed as real samples and good recoveries (98–120%) were obtained.  相似文献   

6.
A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-μm polydimethylsiloxane–divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-μm PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.  相似文献   

7.
We have prepared a fiber for solid-phase microextraction of organochlorine pesticides. A graphene-polyaniline composite was electrochemically deposited on a platinum fiber by exploiting the unique properties of polyaniline and graphene. The modified fiber displays thermal stability up to 320 °C and can be used more than 70 times. It possesses high extraction efficiency due to the high specific surface of graphene. The Pt fiber was used for the extraction and subsequent GC determination of the pesticides heptachlor, aldrin, endrin and p,p’-DDT in aqueous samples. The effects of extraction time, extraction temperature, stirring rate, salinity and headspace volume were optimized. Calibration plots are linear (with an R2 of 0.990) in the 0.2 to 250 μg L–1 concentration range, and the limits of detection are below 11 ng L–1 (at an S/N of 3). The relative standard deviations for three replicate measurements with a single fiber were <11.0 %. The recovery of the pesticides from spiked seawater samples ranged from 81 % to 112 %.
Figure
The graphene–polyaniline (G/PANI) nanocomposite was prepared by simultaneous electropolymerization of G–aniline and used as a new coating for SPME of organochlorine pesticides as model compounds. The large delocalized π-electron system of G and high extraction capability of PANI caused to produce an efficient and sensitive sorbent for SPME  相似文献   

8.
A fiber coating from polyaniline (PANI) was electrochemically prepared and employed for solid phase microextraction (SPME) of some polycyclic aromatic hydrocarbons (PAHs) from water samples. The PANI film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The applicability of this coating was assessed employing a laboratory-made SPME device and gas chromatography with mass spectrometry (GC-MS) for the extraction of some PAHs from the headspace of aqueous samples. Application of wider potential range in CV led to a PANI with more stability against the temperature. The homogeneity and the porous surface structure of the film were examined by the scanning electron microscopy (SEM). The study revealed that this polymer is a suitable SPME fiber coating for extracting the selected PAHs. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 40 degrees C gave maximum peak area, when the aqueous sample was added with NaCl (20%, w/v). The synthesis of the PANI can be carried out conveniently and in a reproducible manner while it is rather inexpensive and stable against most of organic solvents. The film thickness of PANI can be precisely controlled by the number of CV cycles. The resulting thickness was roughly 20 microm after 20 cycles. At the optimum conditions, the relative standard deviation (RSD) for a double distilled water spiked with selected PAHs at ppb level were 8.80-16.8% (n = 3) and detection limits for the studied compounds were between 0.1-6 pg mL(-1). The performance of PANI was, also, compared with a commercial solid coated-based SPME fiber, carbowax/divinylbenzene (CW/DVB), under similar experimental conditions.  相似文献   

9.
A novel dihydroxy-terminated benzo-15-crown-5 is synthesized and applied to prepare the solid-phase microextraction (SPME) fiber coating with sol-gel technology. Headspace SPME, as a simple, solvent-free method, is applied to the analysis of 16 organochlorine pesticides (OCPs) present at trace levels in a water sample. A homemade crown ether fiber coated with 80- micro m thickness was used for extraction. Analyses are performed using gas chromatography-electroncapture detection. The optimization of the extraction process is studied. Compared with commercially available SPME fibers, polydimethylsiloxane, the new phases show better selectivity and sensitivity toward OCPs. The linear concentrations range from 1 to 1000 ng/L, the detection limits are in the range of 0.01-0.5 ng/L, the recoveries are over 85%, and relative standard deviations are below 7.2% for these OCPs.  相似文献   

10.
Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber‐coating material for the solid‐phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene‐coated fiber coupled with high‐performance liquid chromatography‐diode array detection (HPLC‐DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05‐0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0 ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene‐coated fiber showed higher extraction efficiency.  相似文献   

11.
In this study, a novel graphene nanosheets (GNSs) coated solid phase microextraction (SPME) fiber was prepared by immobilizing microwave synthesized GNSs on a stainless steel wire. Microwave synthesized GNSs were verified by X-ray diffraction, field emission-scanning electron microscopy (FE-SEM) and transmission electron microscope (TEM). GNS-SPME fiber was characterized using FE-SEM and the results showed the GNS coating was homogeneous, porous, and highly adherent to the surface of the stainless steel fiber. The performance and feasibility of the GNS-SPME fiber was evaluated under one-step microwave assisted (MA) headspace (HS) SPME followed by gas chromatography with electron capture detection for five organochlorine pesticides (OCPs) in aqueous samples. Parameters influencing the extraction efficiency of MA-HS-GNS-SPME such as microwave irradiation power and time, pH, ionic strength, and desorption conditions were thoroughly examined. Under the optimized conditions, detection limits for the OCPs varied between 0.16 and 0.93 ng L(-1) and linear ranges varied between 1 and 1500 n gL(-1), with correlation coefficients ranging from 0.9984 to 0.9998, and RSDs in the range of 3.6-15.8% (n=5). In comparison with the commercial 100 μm polydimethylsiloxane fiber, the GNS coated fiber showed better extraction efficiency, higher mechanical and thermal stability (up to 290°C), longer life span (over 250 times), and lower production cost. The method was successfully applied to the analysis of real water samples with recoveries ranged between 80.1 and 101.1% for river water samples. The results demonstrated that the developed MA-HS-GNS-SPME method was a simple, rapid, efficient pretreatment and environmentally friendly procedure for the analysis of OCPs in aqueous samples.  相似文献   

12.
A direct solid-phase microextraction (SPME) procedure has been developed and applied for the simultaneous determination of nonylphenol, nonylphenol mono- and diethoxylates and their brominated derivatives in raw and treated water at low microg l(-1) concentrations. Several parameters affecting the SPME procedure, such as extraction mode (headspace or direct-SPME), selection of the SPME coating, extraction time, addition of organic modifiers such as methanol and temperature were optimized. The divinylbenzene-carboxen-polydimethylsiloxane fiber was the most appropriate one for the determination of nonylphenol ethoxylates (NPEOs) and bromononylphenol ethoxylates (BrNPEOs) by SPME-GC-MS. The optimized method was linear over the range studied (0.11-2.5 microg l(-1)) and showed good precision, with RSD values between 4 and 15% and detection limits ranging from 30 to 150 ng l(-1) depending on the compound. The SPME procedure was compared with a solid-phase extraction-GC-MS method (C18 cartridge) for the analysis of NPEO and BrNPEOs in water samples. There was good agreement between the results from both methods but the SPME procedure showed some advantages such as lower detection limits, a shorter analysis time and the avoidance of organic solvents. The optimized SPME method was applied to determine nonylphenol and brominated metabolites in raw and treated water of Barcelona (NE Spain).  相似文献   

13.
Mesoporous TiO2 nanoparticles were synthesized with the hydrothermal method and characterized by powder X-ray diffraction (PXRD) and transmission electron microscope (TEM). Then a superior solid-phase microextraction (SPME) fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and mesoporous TiO2 powder. The developed fiber possessed a homogeneous surface and a long life-span up to 100 times at direct immersing (DI) extraction mode. Under the optimized conditions, the extraction efficiencies of the self-made 17 μm TiO2 fiber for six organochlorine pesticides (OCPs) were higher than those of the two commercial fibers (65 μm PDMS/DVB and 85 μm PA fibers) which were much thicker than the former. As for analytical performance, low detection limits (0.08–0.60 ng L−1) and wide linearity (5–5000 ng L−1) were achieved under the optimal conditions. The repeatabilities (n = 5) for single fiber were between 2.8 and 12.3%, while the reproducibilities (n = 3) of fiber-to-fiber were in the range of 3.7–15.7%. The proposed fiber was successfully applied to the sensitive analysis of OCPs in real water samples and four of the six analytes were detected from the rainwater and the lake water samples.  相似文献   

14.
In this work, a C18 composite solid-phase microextraction (SPME) fiber was prepared with a new method and applied to the analysis of organochlorine pesticides (OCPs) in water sample. A stainless steel wire (o.d. 127 μm) was used as the substrate, and a mixture of the C18 particle (3.5 μm) and the 184 silicone was used as the coating material. During the process of fiber preparation, a section of capillary column was used to fix the mixture onto the stainless steel wire and to ensure the constant of coating thickness. The prepared fiber showed excellent thermal stability and solvent resistance. By coupling with gas chromatography–mass spectrometry (GC–MS), the fiber exhibited wide linearity (2–500 ng L−1) and good sensitivity for the determination of six OCPs in water samples, the OCPs tested included hexachlorobezene, trans-chlordane, cis-chlordane, o,p-DDT, p,p-DDT and mirex. Not only the extraction performance of the newly prepared fiber was more than seven times higher than those of commercial fibers, the limits of detections (LODs) (0.059–0.151 ng L−1) for OCPs achieved under optimized conditions were also lower than those of reported SPME methods. The fiber was successfully applied to the determination of OCPs in real water samples by using developed SPME–GC–MS method.  相似文献   

15.
The fabrication of a solid-phase microextraction (SPME) fiber through UV-induced polymerization of poly(ethylene glycol) diacrylate (PEG-DA) for determination of parabens in cosmetic products is presented in this work. The PEG-DA polymer coating was covalently attached to the fiber by introducing a surface modification with 3-(trichlorosilyl)propyl methacrylate (TPM). The PEG-DA polymer thin film coated on the fiber was homogeneous and wrinkled, which led to an increase of the surface area and high extraction efficiency. The extraction performances of the prepared SPME fibers were assessed by preconcentration of parabens including methylparaben, ethylparaben, propylparaben and benzylparaben from cosmetic products. The analysis was performed on an ultra high-speed liquid chromatography with diode array detector. The prepared SPME fibers exhibited good repeatability (for one fiber) and reproducibility (fiber-to-fiber) with RSDs of 5.4 and 6.9%, respectively. The optimized SPME method supported a wide linear range of 0.50-160 μg/mL and the detection limits for parabens were in the range of 0.12-0.15 μg/mL (S/N=3). The developed method was successfully applied for determination of parabens in cosmetic products with different natures.  相似文献   

16.
In this study, poly(ethylene glycol) (PEG) grafted onto multi-walled carbon nanotubes (PEG-g-MWCNTs) were synthesized by the covalent functionalization of MWCNTs with hydroxyl-terminated PEG chains. For the first time, functionalized product of PEG-g-MWCNTs was used as selective stationary phase to prepare the sol-gel solid-phase microextraction (SPME) fiber in combination with gas chromatography-flame ionization detector (GC-FID) for the determination of ultra-trace levels of benzene, toluene, ethylbenzene and o-xylene (BTEX) in real water samples. The PEG-g-MWCNTs were characterized by Fourier transform infrared spectra and also thermo-gravimetric analysis, which verified that PEG chains were grafted onto the surface of the MWCNTs. The scanning electron micrographs of the fiber surface revealed a highly porous structure which greatly increases the surface area for PEG-g-MWCNTs sol-gel coating. This fiber demonstrated many inherent advantages, the main being the strong anchoring of the coating to the fused silica resulting from chemical bonding with the silanol groups on the fused-silica fiber surface. The new PEG-g-MWCNTs sol-gel fiber is simple to prepare, robust, with high thermal stability and long lifetime, up to 200 extractions. Important parameters influencing the extraction efficiency such as desorption temperature and time, extraction temperature, extraction time, stirring speed and salt effect were investigated and optimized. Under the optimal conditions, the method detection limits (S/N=3) were in the range of 0.6-3 pg mL(-1) and the limits of quantification (S/N=10) between 2 and 10 pg mL(-1). The relative standard deviations (RSDs) for one fiber (repeatability) (n=5) were obtained from 4.40 up to 5.75% and between fibers or batch to batch (n=3) (reproducibility) in the range of 4.31-6.55%. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples at 20 pg mL(-1) were from 90.21 to 101.90%.  相似文献   

17.
In this work cobalt oxide nanoparticles were introduced for preparation of a novel solid phase microextraction (SPME) fiber coating. Chemical bath deposition (CBD) technique was used in order for synthesis and immobilization of the Co3O4 nanomaterials on a Pt wire for fabrication of SPME fiber. The prepared cobalt oxide coating was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. The fiber was evaluated for the extraction of benzene, toluene, ethylbenzene and xylene (BTEX) in combination with GC–MS. A simplex optimization method was used to optimize the factors affecting the extraction efficiency. Under optimized conditions, the proposed fiber showed extraction efficiencies comparable to those of a commercial polydimethylsiloxane (PDMS) fiber toward the BTEX compounds. The repeatability of the fiber and its reproducibility, expressed as relative standard deviation (RSD), were lower than about 11%. No significant change was observed in the extraction efficiency of the new SPME fiber after over 50 extractions. The fiber was successfully applied to the determination of BTEX compounds in real samples. The proposed nanostructure cobalt oxide fiber is a promising alternative to the commercial fibers as it is robust, inexpensive and easily prepared.  相似文献   

18.
固相微萃取中高分子涂层的研究   总被引:34,自引:0,他引:34  
张道宁  吴采樱  艾飞 《色谱》1999,17(1):10-13
聚甲基乙烯基硅氧烷首次被用作固相微萃取(SPME)装置的固相涂层,通过顶空固相微萃取气相色谱分析(HS-SPME-GC)对使用聚甲基乙烯基硅氧烷固相涂层的SPME装置进行了评价。对其使用厚度、温度及选择性进行了较深入的研究,找到了它的最佳使用条件和适用范围,并与商品化的SPME涂层作了比较。对HS-SPME-GC和HS-GC两种方法也作了比较,指出两者的适用范围不同。  相似文献   

19.
A ceramic/carbon composite was developed and applied as a novel coating for solid-phase microextraction (SPME). The ceramic/carbon coating exhibited several good properties for SPME, such as high extraction quantities and enhanced thermal and organic solvent stability. Under scanning electron microscopy (SEM), the tightly attached coating layer on stainless steel wire revealed excellent mechanical characteristics. Single fiber and fiber-to-fiber reproducibility were less than 6.9 and 9.5%, respectively. The effects of extraction and desorption parameters such as extraction time, stirring rate, ionic strength, and desorption temperature and desorption time on the extraction/desorption efficiency were investigated and optimized. Coupled to gas chromatography with a flame thermionic detector, the optimized SPME method was applied to the analysis of organophosphorus pesticides (OPPs) in aqueous samples. The calibration curves were linear from 0.05 to 200 ng mL(-1) for fenchlorphos, pirimiphos-methyl, chlorpyrifos, ethion and from 0.2 to 200 ng mL(-1) for quinalphos, and the limits of detection were between 5.2 and 34.6 ng L(-1). The recovery of the OPPs spiked in real water samples at 5 ng mL(-1) ranged from 86.2 to 103.4% and the relative standard deviations were less than 8.5%.  相似文献   

20.
A solid-phase microextraction (SPME) procedure using three commercialised fibers (Carbowax-divinylbenzene, Carboxen-polydimethylsiloxane and divinylbenzene-Carboxen-polydimethylsiloxane) is presented for the determination of a selected group of organochlorine compounds in water samples. The extraction performances of these compounds were compared using fibers with two and three coatings. The optimal experimental procedures for the adsorption and desorption of pesticides were determined. The limits of detection with the divinylbenzene-Carboxen-polydimethylsiloxane fiber at levels below ng l(-1) were similar or lower than values presented in the literature for several of these compounds using polydimethylsiloxane fiber. The advantages of using this fiber, such as no salt addition, are discussed. Finally, the optimised procedures were applied successfully for the determination of these compounds in polluted ground water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号