首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new Pb(II)-imprinted amino-functionalized silica gel sorbent was synthesized by an easy one-step reaction by combining a surface imprinting technique for selective solid-phase extraction of trace Pb(II) prior to its determination by inductively coupled plasma optical emission spectrometry. The Pb(II)-imprinted amino-functionalized silica gel sorbent was characterized by Fourier transform infrared spectroscopy. Compared to non-imprinted polymer particles, the ion-imprinted polymers had higher selectivity and adsorption capacity for Pb(II). The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Pb(II) was 19.66 and 6.20 mg g?1, respectively. The largest selectivity coefficient of the Pb(II)-imprinted sorbent for Pb(II) in the presence of Cd(II) was over 450. The relative selectivity (α r) values of Pb(II)/Cd(II) were 49.3 and 46.3, which were greater than 1. The distribution ratio (D) values of Pb(II)-imprinted polymers for Pb(II) were much larger than that for Cd(II). The detection limit (3σ) was 0.20 μg L?1. The relative standard deviation was 2.0% for 11 replicate determinations. The method was validated for the analysis three certified reference materials (GBW 08301, GBW 08504, GBW 08511), and the results are in good agreement with standard values. The method was also successfully applied to the determination of trace lead in plants and water samples with satisfactory results.  相似文献   

2.
In this work, β-CD-based polyurethane copolymers (β-CDPU) have been prepared by reacting β-CD with hexamethylene diisocyanate as cross-linked agent in dry DMF. This polymer showed high selectivity for preconcentration of Pb(II) at trace level prior to its flame atomic absorption spectrometric determination. The effect of several parameters such as pH, flow rate of sample, eluent kind and volume was investigated. The adsorption behaviors and mechanisms of Pb(II) on the samples were also studied. The maximum adsorption amount of Pb(II) was 8 mg g?1 with the preconcentration factor of 250 for Pb(II). The Langmuir isotherm was proved to describe the adsorption data better than the Freundlich isotherm and a pseudo-first-order kinetic model fits the adsorption kinetic processes well. The calibration curve was linear in the range of (3–200 ng mL?1) with a correlation coefficient of 0.9996. The limit of detection based on three times the standard deviation of the blank was 1.15 ng mL?1. The relative standard deviations for the determination of 10 and 100 ng mL?1 of Pb(II) were 3.60 and 0.43 % (n = 10), respectively. The method was successfully applied to the determination of lead in some environmental samples such as Tehran and Bushehr drinking water, river water and dust samples.  相似文献   

3.
A solid phase extraction method is presented for the preconcentration of trace lead ions on oxidized multiwalled carbon nanotubes (ox-MWCNTs). In the first step, the cationic Pb(II) complex of 2,2-bipyridyl is formed which, in a second step, is adsorbed on ox-MWCNTs mainly due to electrostatic and van der Waals interactions. The Pb(II) ions were then eluted with dilute nitric acid and quantified by FAAS. The effects of pH value, mass of sorbent, concentration of 2,2-bipyridyl, stirring time, of type, concentration and volume of eluent, of eluent flow rate and sample volume were examined. Most other ions do not affect the recovery of Pb(II). The limits of detection are 240 and 60 ng L?1 for sample volumes of 100 and 400 mL, respectively. The recovery and relative standard deviation are >95 % and 2.4 %, respectively. Other figures of merit include a preconcentration factor of 160 and a maximum adsorption capacity of 165 mg g?1. The method was successfully applied to the determination of Pb(II) in spiked tap water samples. The accuracy of the method was verified by correctly analyzing a certified reference material (NCS ZC85006; lead in tomatoes).
Figure
A solid phase extraction method is presented for the preconcentration of trace lead ions on oxidized multiwalled carbon nanotubes (ox-MWCNTs). Most other ions do not affect the recovery of Pb(II).  相似文献   

4.
《Analytical letters》2012,45(12):1978-1990
A novel absorbent was prepared by sodium dodecyl sulfonate (SDS)-modified activated carbon (SDS-AC) and was employed as the microcolumn packing material for separation/preconcentration of trace Cd(II). The method based on Cd(II) was quantitatively retained by SDS-AC sorbent, which entailed cation exchange nature and negative charged surface, facilitating favorable retention of positively charged ions. The retained Cd(II) was effectively recovered with elution by 1 mol · L?1 HNO3, and the eluent was quantified by electrothermal atomic absorption spectrometry (ET-AAS). Under the optimized conditions, the limit of detection (LOD) for Cd(II) was 3 ng · L?1 with the consumption of 20.0 mL sample solution. The relative standard deviation (RSD) for ten replicate measurements of 50 ng · L?1 Cd(II) was 2.9%. The developed technique was demonstrated for the determination of trace Cd(II) in water samples and the recoveries for spiked samples were found to be in the range of 94.9–107.2%. For validation, two certified reference materials of water samples (GBW08607 and GBW08608) were analyzed, and the results obtained were in good agreement with the certified values.  相似文献   

5.
We report that magnetic multiwalled carbon nanotubes functionalized with 8-aminoquinoline can be applied to the preconcentration of Cd(II), Pb(II) and Ni(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, magnetic sorbent amount, and pH value) were selected as the main factors affecting sorption, and four variables (type, volume and concentration of the eluent; elution time) were selected for optimizing elution. Following sorption and elution, the ions were quantified by FAAS. The LODs are 0.09, 0.72, and 1.0 ng mL?1 for Cd(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations are <5.1 % for five separate batch determinations at 30 ng mL?1 level of Cd(II), Ni(II), and Pb(II) ions. The sorption capacities (in mg g?1) of this new sorbent are 201 for Cd(II), 150 for Pb(II), and 172 Ni(II). The composite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples.
Figure
A schematic diagram for synthesis of functionalized magnetic multiwalled carbon nanotube.  相似文献   

6.
Multiwalled carbon nanotubes were grafted with tris(2-aminoethyl)amine (MWCNTs-TAA) and employed for solid phase extraction and preconcentration of trace lead ions prior to its determination by inductively coupled plasma optical emission spectrometry. The material was characterized by FT-IR and Raman spectroscopy, thermosgravimetric and elemental analysis. The effects of pH value, shaking time, sample volume, elution conditions and potentially interfering ions were investigated. Under the optimum conditions, the maximum adsorption capacity is 38?mg?g?1 of Pb(II), the detection limit is 0.32?ng?mL?1, the enrichment factor is 60, and the relative standard deviation is 3.5% (n?=?6). The method has been applied to the preconcentration of trace amounts of Pb(II) in environmental water samples with satisfactory results.
Figure
Oxidized multiwalled carbon nanotubes grafted with tris(2-aminoethyl)amine (MWCNTs-TAA) is prepared and employed as solid phase extraction sorbent to determinate the trace Pb(II) in water samples. The method has been applied to the preconcentration of trace amount of Pb(II) in water samples with satisfactory results.  相似文献   

7.
A new sorbent S-benzyldithiocarbazate (SBDTC) modified activated carbon (AC-SBDTC) was prepared and studied for preconcentration for trace mercury(II) prior to inductively coupled plasma atom emission spectrometry (ICP-AES). The experimental conditions were optimised with respect to different experimental parameters using both batch and column procedures in detail. The optimum pH value for the separation of Hg(II) on the new sorbent was 3, while the adsorption equilibrium was achieved in less than 5?min. Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 5?mL of 0.25?mol?L?1 of HCl and 2% CS(NH2)2. Common coexisting ions did not interfere with the determination. The maximum static adsorption capacity of the sorbent under optimum conditions was found to be 0.55?mmol?g?1. The detection limit of the present method was found to be 0.09?ng?mL?1, and the relative standard deviation (RSD) was lower than 2.0%. The procedure was validated by analysing the certified reference river sediment material (GBW 08301, China), the results obtained were in good agreement with standard values. This sorbent was successfully employed in the separation and preconcentration of trace Hg(II) from the natural water samples yielding 80-fold concentration factor.  相似文献   

8.
A novel on-line flow injection solid phase extraction method for the preconcentration of trace toxic metals prior determination by flame atomic absorption spectrometry (FI-SPE-FAAS) was developed. The potential application of the hydrophobic reversed phase co-polymer sorbent StrataTM-X packed into an on-line microcolumn for the quantification of Cd(II), Pb(II), Cu(II) and Cr(VI) was demonstrated for the first time. The method was based on the on-line formation of metal complexes using sodium diethyl-dithiocarbamate (DDTC) and on the subsequent retention of them onto the sorbent material. The target analytes were completely eluted by methanol and, subsequently, directed to FAAS for quantification. All chemical and flow variables affecting the performance of the developed method were thoroughly studied and optimised. For a preconcentration time of 90 s and a sampling frequency of 28 h?1, enhancement factors of 72, 140, 185, 63 and detection limits of 0.18, 1.6, 0.20 and 1.2 μg L ?1 were obtained for Cd(II), Pb(II), Cu(II) and Cr(VI), respectively. The accuracy of the FI-SPE-FAAS method was evaluated by analysing certified reference materials as well as spiked environmental water samples. Furthermore, a comparative study of the analytical characteristics, the properties as well as the chemical structures of commercial polymeric based sorbent materials was employed. Strata-X sorbent was compared against HypersepTM SCX, Bond Elut® PlexaTM PCX, Oasis-HLBTM and NobiasTM PA-1, regarding the adaptation in on-line FI-SPE-FAAS systems for metal determination, and herein presented.  相似文献   

9.
A sensitive and simple method has been established for simultaneous preconcentration of trace amounts of Pb (II) and Ni (II) ions in water samples prior to their determination by flame atomic absorption spectrometry. This method was based on the using of a micro-column filled with graphene oxide as an adsorbent. The influences of various analytical parameters such as solution pH, adsorbent amount, eluent type and volume, flow rates of sample and eluent, and matrix ions on the recoveries of the metal ions were investigated. Using the optimum conditions, the calibration graphs were linear in the range of 7–260 and 5–85 μg L?1 with detection limits (3Sb) of 2.1 and 1.4 μg L?1 for lead and nickel ions, respectively. The relative standard deviation for 10 replicate determinations of 50 μg L?1 of lead and nickel ions were 4.1% and 3.8%, respectively. The preconcentration factors were 102.5 and 95 for lead and nickel ions, respectively. The adsorption capacity of the adsorbent was also determined. The method was successfully applied to determine the trace amounts of Pb (II) and Ni (II) ions in real water samples. The validation of the method was also performed by the standard reference material.  相似文献   

10.
We have modified silica-coated Fe3O4 nanoparticles with 2,6-diaminopyridine and used these for selective magnetic solid-phase extraction of trace amounts of metal ions. The nanoparticles were characterized by transmission electron microscopy and Fourier transform infrared spectroscopy. Quantitative extraction of trace amounts of Cu(II) and Zn(II) from mixed-ion solutions was accomplished at an optimal pH value of 6 within less than 10?min. The metal ions were eluted from the sorbent with hydrochloric acid. Common electrolytes and chemically related metal ions do not interfere. The relative standard deviations of the method are <4?%. It was successfully applied to the separation and preconcentration of trace metal ions from the certified reference materials GBW 08301 (river sediment) and GBW 08607 (water solution), in natural water, and in samples of vegetable with satisfying results.  相似文献   

11.
A solid phase extraction method is presented for the selective preconcentration and/or separation of trace Pb(II) on multiwalled carbon nanotubes modified with 2-aminobenzothiazole. Inductively coupled plasma optical emission spectrometry was used for detection. The effects of pH, shaking time, sample flow rate and volume, elution condition and interfering ions were examined using batch and column procedures. An enrichment factor of 100 was accomplished. Common other ions do not interfere in both the separation and determination. The maximum adsorption capacity of the sorbent at optimum conditions is 60.3?mg?g?1 of Pb(II), the detection limit (3??) is 0.27?ng?mL?1, and the relative standard deviation is 1.6% (n?=?8). The method was validated using a certified reference material, and has been applied to the determination of trace Pb(II) in water samples with satisfactory results.
Figure
2-Aminobenzothiazole modified multiwalled carbon nanotubes has been developed to separate and concentrate trace Pb(II) from aqueous samples. Parameters that affect the sorption and elution efficiency were studied in batch and column modes, and the new sorbent (MWCNTs-ABTZ) presents high selectivity and adsorption capacity for the solid phase extraction of trace Pb(II).  相似文献   

12.
Immobilization of β-cyclodextrin on Dowex resin as an insoluble polymeric matrix by covalent bond presents a new solid-phase medium for preconcentration of Pb (II) at trace level in environmental samples prior to its flame atomic absorption spectrometric determination. The method is based on the sorption of lead after passing on modified Dowex sorbent in a column. The effect of several parameters such as pH, flow rate of sample, eluent kind and volume was investigated. The sorption capacity of the matrix has been found to be 0.4996?mg?g?1 of adsorbent with the preconcentration factor of 250 for Pb (II). Nitric acid (3 M) as an eluent was sufficient to obtain quantitative recovery (>95%) for Pb (II). The optimum flow rate was 10?ml?min ?1. The calibration curve was linear in the range of (3–250?ng?mL?1) with a correlation coefficient of 0.9995. The limit of detection (LOD) based on three times the standard deviation of the blank was 1.37?ng?mL?1. The relative standard deviation (RSD) for determination of 10?ng?mL?1 and 100?ngmL?1 of Pb (II) was 3.00 % and 0.58 % (n?=?10), respectively. The method was successfully applied to determination of lead in some environmental samples such as tap water, river water, soil and rice.  相似文献   

13.
A new method that utilizes ethylenediamine-modified activated carbon (AC-EDA) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) prior to the measurement by inductively coupled plasma optical emission spectrometry (ICP-OES). The new sorbent was prepared by oxidative surface modification. Experimental conditions for effective adsorption of trace levels of Cr(III), Fe(III), Hg(II) and Pb(II) were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4.0. Complete elution of absorbed metal ions from the sorbent surface was carried out using 3.0 mL of 2% (%w/w) thiourea and 0.5 mol L−1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.4, 28.9, 60.5 and 49.9 mg g−1 for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The time for 94% adsorption of target metal ions was less than 2 min. The detection limits of the method was found to be 0.28, 0.22, 0.09 and 0.17 ng mL−1 for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The precision (R.S.D.) of the method was lower 4.0% (n = 8). The prepared sorbent as solid-phase extractant was successfully applied for the preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) in natural and certified samples with satisfactory results.  相似文献   

14.
We report on the separation and preconcentration of lead(II) and copper(II) ions using silver-coated titanium dioxide nanoparticles modified with cysteamine, and their determination by slurry analysis via flame atomic absorption spectrometry. The ions were adsorbed via a conventional batch technique, and the ion-loaded slurry was separated and directly introduced into the spectrometer, thereby eliminating a number of drawbacks. The effects of pH, amount of sorbent, slurry volume, sample volume and other ions on the recovery were investigated. Under optimized experimental conditions, copper and lead can be recovered within the 95% confidence level in certificated waste water, but also in spiked sea water samples. The technique is fast, simple, and leads to complete elution. The limit of detection (3δ, at n?=?10) was 0.37 μg L?1 for Cu(II), and 0.38 μg L?1 for Pb(II).
Figure
We report on the separation and preconcentration of lead(II) and copper(II) ions using silver-coated titanium dioxide nanoparticles modified with cysteamine (Fig. 1), and their determination by slurry analysis via flame atomic absorption spectrometry. Under optimized experimental conditions, copper and lead can be recovered within the 95% confidence level in certificated waste water and spiked sea water samples. The technique is fast, simple, and leads to complete elution. Figure 1. Schematic illustration of the preparation of TiO2@Ag–Cysteamine nanoparticles and inset shows the color of the nanoparticles.  相似文献   

15.
Attapulgite modified with 2-hydroxy-1-naphthaldehyde was prepared and applied to the separation, preconcentration and determination of Cu(II) in aqueous solutions by inductively coupled plasma optical emission spectrometry. Experimental conditions for effective adsorption of trace levels of Cu(II) were optimized using batch and column procedures. The optimum pH value for the separation of Cu(II) on the newly sorbent was 4.0 and complete elution of Cu(II) from the sorbent surface was carried out using 2 mL of 0.01 mol L?1 HCl. The adsorption capacity for Cu(II) was 25.13 mg g?1. The detection limits of the method defined by IUPAC were found to be 0.24 μg L?1 with enrichment factor of 150. The method has been applied to the determination of Cu(II) in certified reference materials and natural water samples with satisfactory results.  相似文献   

16.

We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles that were prepared by direct silylation of magnetic nanoparticles with 3-aminopropyltriethoxysilane-2,4-bis(3,5-dimethylpyrazol)-triazine. The sorbent was characterized by IR spectroscopy, X-ray powder diffraction, scanning electron microscopy, thermal and elemental analysis. The sorbent was applied to the preconcentration of lead and cadmium ions which then were quantified by FAAS. The effects of sample pH value, extraction time, of type, concentration and volume of eluent, and of elution time were optimized. The limits of detection are 0.7 ng mL−1 for Pb(II) ion and 0.01 ng mL−1 for Cd(II). The effects of potentially interfering ions often found in real samples on the recovery in the determination of cadmium and lead ions in real samples were also investigated. The accuracy of the method was confirmed by analyzing the certified reference materials NIST 1571 (orchard leaves) and NIST 1572 (citrus leaves). Finally, the method was successfully applied to the determination of cadmium and lead ions in some fruit samples.

We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles. After optimization of the preconcentration step the method was successfully applied to the determination of cadmium and lead ions in some fruit samples

  相似文献   

17.
An organo-nanoclay is used as a new, easily accessible, and stable solid sorbent for the preconcentration of trace amounts of rhodium ions from aqueous solution, this followed by its determination by flame atomic absorption spectrometry (FAAS). Rh(III) ion was first complexed with 2,3,5,6-tetra(2-pyridyl) pyrazine (TPPZ) at pH values between 3.0 and 4.7, and then the complex was then adsorbed onto the nanoclay. The rhodium ions were eluted from the sorbent with HCl. The rhodium in the effluent was determined by FAAS. The linear analytical range is between 0.14 ng mL?1 and 20.0 μg mL?1 in the initial solution, the relative standard deviation at 2.0 μg mL?1 of rhodium is 2.6% (n?=?8), the detection limit is 0.03 ng mL?1, and the preconcentration factor is 140. Experimental parameters including the pH, eluent type, interference by other ions and breakthrough volume were optimized. The method was applied to the determination of rhodium in water, road dust and synthetic samples.  相似文献   

18.
A new solid-phase extraction sorbent was used for the preconcentration of Pb(II) and Cr(III) ions prior to their determination by flame atomic absorption spectrometry. It was prepared by immobilization of 2,4-dinitrophenylhydrazine on nano-alumina coated with sodium dodecyl sulfate. The sorbent was characterized by scanning electron microscopy, N2 adsorption and Fourier transform infrared spectrometry, and used for preconcentration and separation of Pb(II) and Cr(III) from aqueous solutions. The ions on the sorbent were eluted with a mixture of nitric acid and methanol. The effects of sample pH, flow rates of samples and eluent, type of eluent, breakthrough volume and potentially interfering ions were studied. Linearity is maintained between 1.2 and 350???g?L-1 of Pb(II), and between 2.4 and 520???g?L-1 of Cr(III) for an 800-mL sample. The detection limit (3?s, N?=?10) for Pb(II) and Cr(III) ions is 0.43 and 0.55???g?L-1, respectively, and the maximum preconcentration factor is 267. The method was successfully applied to the evaluation of these trace and toxic metals in various water, food, industrial effluent and urine samples.
Figure
Recovery percentage of Pb(II) and Cr(III) ions at different solution volumes.  相似文献   

19.
We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles that were prepared by direct silylation of magnetic nanoparticles with 3-aminopropyltriethoxysilane-2,4-bis(3,5-dimethylpyrazol)-triazine. The sorbent was characterized by IR spectroscopy, X-ray powder diffraction, scanning electron microscopy, thermal and elemental analysis. The sorbent was applied to the preconcentration of lead and cadmium ions which then were quantified by FAAS. The effects of sample pH value, extraction time, of type, concentration and volume of eluent, and of elution time were optimized. The limits of detection are 0.7 ng mL?1 for Pb(II) ion and 0.01 ng mL?1 for Cd(II). The effects of potentially interfering ions often found in real samples on the recovery in the determination of cadmium and lead ions in real samples were also investigated. The accuracy of the method was confirmed by analyzing the certified reference materials NIST 1571 (orchard leaves) and NIST 1572 (citrus leaves). Finally, the method was successfully applied to the determination of cadmium and lead ions in some fruit samples. Figure
We report on a new sorbent for preconcentration of cadmium and lead ions that is based on triazine-functionalized magnetite nanoparticles. After optimization of the preconcentration step the method was successfully applied to the determination of cadmium and lead ions in some fruit samples  相似文献   

20.
Ofloxacin was successfully used as a chemical modifier to improve the reactivity of silica gel in terms of selective binding and extraction of heavy metal ions. This new functionalised silica gel (SG-ofloxacin) was as an effective sorbent for the solid-phase extraction (SPE) of Cd(II) and Pb(II) in biological and natural water samples and their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). Experimental conditions for effective adsorption of trace levels of Cd(II) and Pb(II) were optimised with respect to different experimental parameters using the batch and column procedures. The time for 70% sorption for Cd(II) and Pb(II) was less than 2 min. Complete elution of the adsorbed metal ions from the SG-ofloxacin was carried out using 2.0 mL of 0.5 mol L?1 of HCl. Common coexisting ions did not interfere with the separation and determination at pH 4.0. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.17 and 48.69 mg g?1 for Cd(II) and Pb(II), respectively. The detection limits of the method were found to be 0.29 and 0.13 ng mL?1 for Cd(II) and Pb(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was lower than 3.0% (n = 5). The method was applied to the recovery of Cd(II) and Pb(II) from the certified reference material (GBW 08301, river sediment) and to the simultaneous determination of these cations in different water and biological samples with satisfactory results and yielding 100-folds enrichment factor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号