1.
In this study, a carbon paste electrode modified with a novel 1-(3-aminopropyl) imidazole functionalised crosslinked chlorosulfonated poly(styrene)-divinyl benzene polymer was used for selective and sensitive determination of the trace amounts of Pb2+, Cu2+ and Hg2+ ions by square wave anodic stripping voltammetry. The effect of some parameters such as paste composition, pH, preconcentration time, reduction potential and time, type of supporting electrolyte and potential scan rate on the determination of metal ions were investigated to find the optimal conditions. The effective open-circuit accumulation of the studied metal ions was succeeded only by the modification of the carbon paste electrode with functional polymer. For 6 min open-circuit preconcentration, the detection limit of Pb2+, Cu2+ and Hg2+ was found to be 5, 9 and 14 µgL?1, respectively at 100 mVs?1. The results confirmed that the lower concentration levels of these trace metal ions can be determined with the increase of preconcentration time and/or potential scan rate. Good detection limits and large dynamic concentration ranges were also obtained for their binary and ternary mixtures. The optimised method was successively applied to determine the concentration of Pb2+, Cu2+ ions in the tap water sample and Cu2+ ion in the waste water sample in the presence of possible interfering species (RSD<1%, recoveries 96–110% for 4 min preconcentration).  相似文献   

2.
A selective separation and preconcentration method for the determination of gold ions in water and ore samples has been developed using dispersive liquid–liquid microextraction, followed by flame atomic absorption spectrometry. 4-Ethyl-1(2-(4-(4-nitrophenyl)piperazin-1-yl)acetyl)thiosemicarbazide) (NPPTSC) has been used for the first time as new chelating reagent. A mixture of ethanol (dispersive solvent) and carbon tetrachloride (extraction solvent) was used. Some parameters affecting the extraction procedure including the type and volume of the extracting and dispersive solvents, HNO3 concentration, the chelating agent amount, volume of sample, and foreign ions have optimized. Also, the complex formation between gold ions and the ligand has been investigated in a methanol–water solution (1:1) using UV–visible spectrometry. The spectrophotometric titration data showed that of Au–NPPTSC complex composition was found to be 3:2. After optimizing the instrumental and experimental parameters, we achieved a detection limit of 1.5 µg L?1, a preconcentration factor of 50, and a linear dynamic range of 10.0–400.0 µg L?1. The relative standard deviation obtained 2.1% at 50 µg L?1 for gold ions (n = 10). The proposed method was successfully performed for the determination of gold in certified reference material, environmental water, and ore samples.  相似文献   

3.
In the present study, the ?5-(4-dimethylaminobenzylidene)rhodanin-modified SBA-15? was applied as stable solid sorbent for the separation and preconcentration of trace amounts of cobalt ions in aqueous solution. SBA-15 was modified by ?5-(4-dimethylaminobenzylidene)rhodanin reagent. The sorption of Co2+ ions was done onto modified sorbent in the pH range of 6.8–7.9 and desorption occurred in 5.0 mL of 3.0 mol L?1 HNO3. The results exhibit a linear dynamic range from 0.01 to 6.0 mg L?1 for cobalt. Intra-day (repeatability) and inter-day (reproducibility) for 10 replicated determination of 0.06 mg L?1 of cobalt was ±1.82% and ?±1.97%?. Detection limit was 4.2 µg L?1 (3Sb, n = 5) and preconcentration factor was 80. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type and interference ions were studied for the preconcentration of Co2+. The proposed method was applied for the determination of cobalt in standard samples, water samples and agricultural products.  相似文献   

4.
In this work, a hydrophilic task-specific ionic liquid (TSIL) of 1-chloroethyl-3-methylimidazolium chloride functionalized with 8-hydroxyquinoline was used in a dispersive liquid–liquid microextraction method followed by flame atomic absorption spectrometry for the enrichment and determination of trace amounts of cadmium (Cd2+) ions. The simultaneous chelation and extraction of Cd2+ ions was carried out by the TSIL. Fine droplets of the water-immiscible TSIL containing target analyte were generated in situ by addition of an anion exchanger potassium hexafluorophosphate (KPF6) salt to the sample tube. After phase separation by centrifugation for 4 min, the sedimented TSIL was diluted with acidified ethanol for measurement of Cd2+ content. Some significant parameters influence the preconcentration of Cd2+ ions such as sample pH, TSIL volume, amount of KPF6, non-ionic surfactant and salt concentration were investigated. Under the optimal conditions, calibration curve was linear in the range of 5–250 µg L?1 Cd2+ with correlation coefficient of 0.9975 and a detection limit of 0.55 µg L?1. The relative standard deviation for six replicate measurements of 50 µg L?1 Cd2+ was 1.5%. The method was successfully applied for the extraction and determination of Cd2+ ions in water and food samples.  相似文献   

5.
A simple and sensitive method is presented for solid phase extraction (SPE) and preconcentration of trace quantities of beryllium using octadecyl silica gel modifed with aurin tricarboxylic acid (aluminon). Beryllium is then determined by flame atomic absorption spectroscopy. Parameters affecting SPE such as pH, sample solution and eluent flow rate, type, concentration and volume of eluent, interfering ions and breakthrough volume, were investigated. Under optimal conditions, the beryllium ions were retained on the sorbent at pH 6–6.7, while 3.0 mL of 0.05 mol L?1 HNO3 is sufficient to elute the ions. The limit of detection (LOD) based on 3σ was 0.8 µg L?1 for 250 mL sample solution and 5 mL 0.05 mol L?1 HNO3 as eluent. The LOD can reach 0.1 µg L?1 for 1 L sample solution and 3 mL of 0.05 mol L?1 HNO3. The accuracy and precision (RSD %) of the method is >90% and <10%, respectively. The method was applied to the determination of beryllium in aqueous samples.  相似文献   

6.
In this work, a solidified floating organic drop microextraction was developed based on a vesicular supramolecular solvent consisting of decanoic acid and quaternary ammonium. The method was used for preconcentration of trace amount of cadmium in different rice samples followed by flow-injection analysis–flame atomic absorption spectrometry. Several parameters affecting the extraction efficiency including pH, concentration of 1-(2-pyridylazo)-2-naphthol as the chelating agent, sample and extraction solvent volume, stirring rate, extraction time, salt effect, and interfering ions were investigated and optimized. Under the optimum conditions, a preconcentration factor of 84 was achieved. LOD and LOQ were found to be 0.09 and 0.31 µg L?1, respectively. The calibration curve was linear within the range of 5.0–700 µg L?1 (r2?>?0.9978). Intra- and inter-day precisions (RSD% n?=?3) were estimated 2.7 and 3.9% at the concentration of 20 µg L?1, respectively. The accuracy of the method was successfully validated by analysis of an SRM-1643f standard reference material. Relative recoveries were achieved within the range of 93–107% elucidating suitability of the method for determination of cadmium in rice samples.  相似文献   

7.
A new solid phase extraction method for the separation and preconcentration of Pd(II) was developed. As solid phase material, a new chelating polymer, poly [N-(4-bromophenyl)-2-methacrylamide-co-2-acrylamido-2-methyl-1-propanesulfonic acid - co-divinylbenzene] was synthesized. The parameters such as the effect of pH, eluent type, volume and concentration, flow rate of sample solution, sample volume and effect of interfering ions for the preconcentration of Pd(II) were investigated. The optimum pH was found to be 9. Eluent for quantitative elution was 10 mL of 1 mol L?1 HCl. The preconcentration factor of the method was 75. At optimum conditions, the recovery for Pd(II) was found to be 101?±?4%. The limit of detection (3σ) was 1.1?µg L?1. The method was applied to the determination of palladium in tap water and converter samples with satisfactory results.  相似文献   

8.
The present paper describes the feasibility of on-line preconcentration of nickel ions from aqueous medium on Ni(II)-imprinted cross-linked poly(methacrylic acid) (IIP) synthesised through a double-imprinting method and their subsequent determination by FAAS. The proposed method consisted in loading the sample (20.0 mL, pH 7.25) through a mini-column packed with 50 mg of the IIP for 2 min. The elution step was performed with 1.0 mol L?1 HNO3 at a flow rate of 7.0 mL min?1. The following parameters were obtained: quantification limit (QL) – 3.74 µg L?1, preconcentration factor (PF) – 36, consumption index (CI) – 0.55 mL, concentration efficiency (CE) – 18 min?1, and sample throughput – 25 h?1. The precision of the procedure assessed in terms of repeatability for ten determinations was 5.6% and 2.5% for respective concentrations of 5.0 and 110.0 µg L?1. Moreover, the analytical curve was obtained in the range of 5.0–180.0 µg L?1 (r = 0.9973), and a 1.64-fold increase in the method sensitivity was observed when compared with the analytical curve constructed for the NIP (non-imprinted polymer), thus suggesting a synergistic effect of the Ni(II) ions and CTAB on the adsorption properties of the IIP. The practical application of the adsorbent was evaluated from an analysis of tap, mineral, lake and river water. Considering the results of addition and recovery experiments (90.2–100 %), the efficiency of this adsorbent can be ensured for the interference-free preconcentration of the Ni(II) ions.  相似文献   

9.
《Analytical letters》2012,45(1-3):216-231
The present work reports the effectiveness of a 2D imprinting method based on a surface imprinting technique for the development of a selective and sensitive flow sorbent preconcentration system for Co2+ ion determination. Cobalt ions were determined by UV-vis spectrophotometry exploiting the complexation with 1-(2-piridylazo)-2-naphtol (PAN). Based on a coefficient of relative selectivity (k'), the ion-imprinted amino-functionalized silica gel sorbent (ISG), compared with modified but non-imprinted sorbent (MSG) and silica gel (SG), showed a very high selectivity. A limit of detection of 0.51 µg L?1 and precision (n = 10) as a relative standard deviation of 2.63 and 1.50% for Co2+ concentration of 10.0 and 90.0 µg L?1, respectively, were achieved. A comparison of the proposed method with other previously published methods shows advantages in terms of sample consumption, sample throughput, and limit of detection. The application of the present method was successfully performed for the direct determination of Co2+ content in urine and environmental water samples without any interference and without sample preparation, with satisfactory results.  相似文献   

10.
A new effervescence-assisted dispersive liquid-liquid microextraction, EA-DLLME, technique was developed for preconcentration and flame atomic absorption spectrometric determination of copper in aqueous samples. Effervescence assistance and DES combination for metal ion extraction was used for the first time. In the presented study, six different effervescence powders were examined to achieve maximum extraction efficiency. In addition, 1,5 diphenyl carbazide was used as complexing agent and DES prepared by mixing choline chloride and phenol was used as extraction solvent. The effect of several parameters such as pH, concentration of complexing agent, composition and volume of DES, amount of THF, composition and amount of effervescent agent were examined. Performed experiments showed that optimum pH was 6.0, the best effervesce powder composition was NaH2PO4:Na2CO3 with 2 × 10?3:1 × 10?3 molar ratio and the amount of effervesce powder was 0.4 g. Under optimum conditions enhancement factor, limit of detection and limit of quantification were calculated as 78, 2.9 and 9.7 μg L?1, respectively. In addition, to prove precision of the method intra-day relative standard deviations were calculated for 10 and 50 μg L?1 Cu2+ concentrations and found as 2.1% and 1.3%, respectively. The proposed method showed good linearity within the range of 10.0–100 μg L?1. Finally, proposed method was successfully applied to determination of copper traces in aqueous samples.  相似文献   

11.
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.  相似文献   

12.
Since the copper ions (Cu2+) play a fatal role in many foundational physiological processes, it is important to develop a simple, highly sensitive and selective sensor for Cu2+ detection in living systems. Herein, an intramolecular charge transfer (ICT) and dansyl-based fluorescent chemosensor 1 was designed, synthesized and characterized for the sensitive and selective quantification of Cu2+. It exhibited remarkable fluorescence quenching upon addition of Cu2+ over other selected metal ions, attributed to the complex formation between 1 and Cu2+ with the association constant 6.7 × 105 M?1. The sensor 1 showed a fast and linear response towards Cu2+ in the concentration range from 0 to 12.5 × 10?6 mol L?1 with the detection limit of 2.5 × 10?7 mol L?1. This detection could be carried out in a wide pH range of 5.0–14. Furthermore, sensor 1 can be used for detecting Cu2+ in living cells.  相似文献   

13.
A solid phase extraction system for separation and preconcentration of trace amounts of Pb(II), Ni(II), Cd(II) and Cu(II) is proposed. The procedure is based on the adsorption of Pb2+, Ni2+, Cd2+ and Cu2+ ions on a column of 1-(2-pyridylazo)-2-naphthol (PAN) immobilised on surfactant-coated clinoptilolite prior to their determinations by Flame Atomic Absorption Spectroscopy (FAAS). The effective parameters including pH, sample volume, sample flow rate and eluent flow rate were also studied. The analytes collected on the column were eluted with 5 mL of 1 mol L?1 nitric acid. A concentration factor of 180 can be achieved by passing 900 mL of sample through the column. The detection limits (3 s) for Cd, Cu, Pb and Ni were found to be 0.28, 0.12, 0.44 and 0.46 µg L?1, respectively. The relative SDs at 10 µg L?1 (n = 10) for analytes were in the range of 1.2–1.4%. The method was applied to the determination of Pb, Ni, Cd and Cu in water samples.  相似文献   

14.
A rapid method for the extraction and monitoring of nanogram level of Pb2+, Cu2+ and Zn2+ ions using uniform silanized mesopor (SBA-15) functionalized with diethylenetriamine groups and flame atomic absorption spectrometry (FAAS) is presented. The preconcentration factor of the method is 100 and detection limit of the technique is 5.5?ng?mL?1 and 1.4?ng?mL?1 and 0.1?ng?mL?1 for Pb2+, Cu2+ and Zn2+ respectively. The time and the optimum amount of the sorbent, pH and minimum amount of acid for stripping of ions from functionalized SBA-15 were tested. The maximum capacity the functionalized SBA-15 was found to be 183.0 (±1.9) µg, 156.0 (±1.5) µg and 80.0 (±1.6) µg of Pb2+, Cu2+ and Zn2+/mg functionalized SBA-15, respectively.  相似文献   

15.
The supramolecular solvent system consists of tetrahydrofuran (THF) and 1-decanol, that was used as an extraction solvent for a microextraction procedure for the preconcentration and separation of Co(II). The proposed supramolecular-based procedure was combined with microsampling flame atomic absorption spectrometry for the determination of cobalt at trace levels in water samples. N-Benzoyl-N,N-diisobutylthiourea was used to chelate Co(II) in an aqueous solution. Quantitative extraction efficiency was obtained at pH 6.5. The effects of analytical parameters including pH, amount of ligand, type, ratio and volume of supramolecular solvent, sample volume and interfering ions were investigated for optimisation of the procedure. The proposed supramolecular solvent-based microextraction procedure (Ss-ME) exhibits a limit of detection (LOD) of 1.29 µg L?1 and a limit of quantification (LOQ) of 3.88 µg L?1. The procedure was validated by addition/recovery tests and by applying TMDA 64.2 and TMDA 53.3 water certified reference materials. The microextraction method was successfully applied for the preconcentration and determination of cobalt in water samples.  相似文献   

16.
A Pb2+ ion selective membrane electrode based on poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) Zr(IV) monothiophosphate composite cation exchange material was fabricated using solution casting method. The effect of membrane composition on the proton exchange capacity was investigated by using varying amounts of electroactive material. The membrane with 250 mg of electroactive material and 10 µL of plasticiser exhibited higher proton conductivity. The optimised membrane composition was used for the fabrication of ion selective membrane electrode which exhibited typical Nernstian response towards Pb2+ ions in the concentration range 20.70 gL?1–20.7 µgL?1 (1 × 10–1–1 × 10–7 mol L?1) with a sub-Nernstian slope of 27.429 mV per decade change in Pb2+ ion concentration. The response time of the electrode under study for Pb2+ ions was found to be 11 s and the electrode can be used for 120 days without any considerable divergence in response potential. It can also be successfully used in the pH range from 3.0 to 6.5. It was found selective for Pb2+ ions in the presence of various monovalent, divalent and trivalent interfering metal ions. It was also employed as an indicator electrode in the potentiometric titration of Pb2+ ions using ethylenediaminetetraacetic acid, disodium salt, as a titrant.  相似文献   

17.
A magnetic composite of silver/iron oxides/carbon nanotubes (Ag/Fe3O4/CNTs) was synthesized and used as an adsorbent for the preconcentration of mercury ions in water solutions at room temperature (25°C) in this study. The silver nanoparticles were supported on the magnetic CNTs. The modification enabled the composite had not only a high adsorption capacity for mercury ions (Hg2+) but also the magnetic isolation properties. A fast, sensitive, and simple method was successfully developed for the preconcentration and determination of trace amount of Hg2+ in water using the synthesized nanocomposite as adsorbent. The mercury concentration was determined by an atomic fluorescence spectrometer (AFS). The experimental conditions such as pH value, extraction temperature, extraction time, sample volume, eluent composition and concentration, sorbent amount, and coexisting ions were investigated for the optimization. A 500 mL of sample volume resulted in a preconcentration factor of 125. When a 200 mL of sample was employed, the limit of detection for Hg2+ was as low as 0.03 ng mL?1with relative standard deviation of 4.4% at 0.1 ng mL?1 (n = 7). The ease of synthesis and separation, the good adsorption capacity, and the satisfactory recovery will possibly make the composite an attractive adsorbent for the preconcentration of ultratrace Hg2+ in waters.  相似文献   

18.
In this work, magnetic solid-phase extraction based on sodium dodecyl sulfate-coated Fe3O4 nanoparticles has been successfully applied for extraction and preconcentration of trace amounts of nystatin from water and vaccine samples prior to high-performance liquid chromatography–ultraviolet detection. Various experimental parameters affecting extraction and recovery of the analyte, such as the amount of sodium dodecyl sulfate, pH of the sample solution, salt concentration, extraction time, sample volume and desorption conditions, were systematically studied and optimized. Under optimized conditions, nystatin was quantitatively extracted. Proper linear range with good coefficient of determination, (R 2 > 0.99) and limit of detection and quantification (based on signal-to-noise ratios of 3 and 10) of 2.0 and 5.0 µg L?1, over the investigated concentration range (5–700 µg L?1), were obtained, respectively. The intra-day and inter-day relative standard deviations at 50 µg L?1 level of NYS were 1.4 and 4.5% based on six replicate determinations. The accuracy of the method was evaluated by recovery measurements on spiked samples. Suitable recoveries of 96–102 and 26–44% were achieved (at spiked levels of 50, 300 and 500 µg L?1) for water and vaccine samples, respectively.  相似文献   

19.
A novel macrocyclic calix[4]arene derivative was examined as an ionophore for ion‐selective polymeric membrane electrode toward Cu+2 ions. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 8.1×10?6 to 1.0×10?2 mol L?1 with a slope of 34.2±0.4 mV per concentration decade in an acidic solution (pH 5). The limit of detection was 0.47 µg mL?1. It had a response time of <20 s and can be used for at least 3 months without any divergence in potentials. The influence of plasticizer as well as the amount of lipophilic anionic site additive in the sensing membrane was discussed. It was shown that membrane electrodes formulated with the ionophore and appropriate anionic additive exhibited enhanced potentiometric response toward Cu2+ over all other cations tested. Since selectivity toward Cu2+ ions is decreased in the presence of high amount of the anionic additive, the ionophore can function as neutral carriers within the organic membrane phase. Validation of the assay method revealed good performance characteristics, including long life span, good selectivity for Cu2+ ions over a wide variety of other metal ions, long term response stability, and high reproducibility. The sensors were used for direct measurement of copper content in different rocks collected from different geological zones. The results agreed fairly well with data obtained using atomic absorption spectrometry.  相似文献   

20.
A simple, sensitive and reliable method has been developed for separation and preconcentration of chromium (VI) from aqueous samples before determination by electrothermal atomic absorption spectrometry. The method is based on the extraction of the hydrophobic complex of chromium (VI) with ammonium pyrrolidine dithiocarbamate in the coacervates made up of decanoic acid reverse micelles in the water–tetrahydrofuran mixture. Parameters affecting the extraction efficiency of the analyte were studied and optimised. Under the optimum conditions, the linear range, enhancement factor, the limit of detection and limit of quantification were found to be 0.008–0.4 µg L?1, 127, and 1.8 ng L?1 and 6.0 ng L?1, of Cr(VI), respectively. The relative standard deviation at the concentration level of 0.1 µg L?1 Cr(VI) (n = 6) was 4.2%. Total chromium was determined after the oxidation of Cr(III) to Cr(VI) with permanganate in acidic medium. The method was successfully applied to the determination of chromium species in water and human serum samples.  相似文献   