1.
Three different liquid chromatography-mass spectrometry (LC-MS) instruments equipped with triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole-time-of-flight (QqTOF), suitable to carry out tandem mass spectrometry, were examined to determine pesticide residues in food. Twelve pesticides (acrinathrin, bupirimate, buprofezin, cyproconazole, lambda-cyhalothrin, fluvalinate, hexaflumuron, kresoxim-methyl, propanil, pyrifenox, pyriproxyfen and tebufenpyrad) and six matrices (oranges, strawberries, cherries, peaches, apricots and pears) were taken as model. The comparison was focused on two aspects: the quantitative, covering sensitivity, precision and accuracy as well as the qualitative, checking the possibility to identify any metabolite present in the samples, which were not targeted in the methods. The extraction was carried out using pressurized liquid extraction (PLE) with ethyl acetate and acid alumina. Recoveries were over 70 % for all the analytes. Repeatabilities were better for the QqQ (5-12%) than for QIT (6-15%) and for QqTOF (14-19%). QqQ offered a linear dynamic range of at least three orders of magnitude, whereas those of QIT and QqTOF were two and one orders of magnitude, respectively. QqQ reached at least 20-fold higher sensitivity than QIT and QqTOF. However, the QqQ failed to identify non-target compounds. QIT and QqTOF were able to successfully identify the metabolite of bupirimate, ethirimol. Application to monitor the content in fruits, taken from agricultural cooperatives, and to calculate the estimated daily intake (EDI) to establish if there is any difference of toxicological interest is also reported.  相似文献   

2.
Within the European Union the use of anabolic steroids for promoting growth and improving meat-to-fat ratio in food-producing animals has been banned since 1988. For the unequivocal identification of hormone residues in a complex matrix such as meat we have developed a rapid, specific and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, in combination with a simple extraction procedure based on the matrix solid-phase dispersion (MSPD). The performances of a triple quadrupole (QqQ) and a quadrupole/time-of-flight (QqTOF) were compared: the QqQ mass spectrometer was found to be more sensitive for almost all studied analytes, but the selectivity was superior using the QqTOF system; the full-scan spectra (acquired without losing sensitivity), mass accuracy and resolution of the hybrid instrument enabled a more probatory analyte identification than that obtained selecting two multiple-reaction monitoring (MRM) transitions with a QqQ. Average recoveries ranged from 80 to 100%, and the detection capabilities (CCbetas) were less than 1.06 ppb with the QqQ instrument and less than 5.20 ppb with the QqTOF instrument for the bovine meat, which proved to be the most complex matrix.  相似文献   

3.
A new multiresidue method has been developed and validated for the determination of more than 140 pesticide residues in cucumber and orange by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS) in a single run of 25.50 min. The triple quadrupole (QqQ) analyzer simultaneously operated in the selected reaction monitoring (SRM) and selected ion monitoring (SIM) modes, acquiring two or three transitions per compound. Samples were extracted by the application of a single-phase extraction of 10 g of sample with acetonitrile containing 1% of acetic acid, followed by a liquid-liquid partition formed by the addition of 4 g of MgSO(4) and 1 g of NaOAc. A dispersive solid-phase extraction (D-SPE) with primary secondary amine (PSA) was applied to clean up the extracts. A final concentration step was included in order to increase sensitivity in the instrumental analysis. The method was properly validated in each matrix in a wide dynamic range (10-400 microg kg(-1)): this work relies on a new quantification strategy by the use of two calibration curves to increase the dynamic range, which permitted reduction of sample dilutions and increase in sample throughput. Recovery was studied at three concentration levels (11.5, 50.0, and 150.0 microg kg(-1)), yielding values in the range 70-110% with precision values, expressed as relative standard deviation (RSD), lower than 20 and 25% for the intraday and interday precision, respectively. Limits of quantification (LOQs) were established at 10 microg kg(-1), the lowest maximum residue level (MRL) value set by the European Union in vegetables. The method was successfully applied to the analysis of pesticide residues in real samples from the southeastern Spain. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

4.
A new multiresidue method has been developed and validated for the simultaneous analysis of 57 compounds, including organochlorine and organophosphorus pesticide residues (OCPs and OPPs) and polychlorinated biphenyls (PCBs), in eggs at trace levels by gas chromatography coupled to triple quadrupole mass spectrometry (GC-QqQ-MS/MS). Egg samples were extracted by a simple and fast matrix solid phase dispersion (MSPD) procedure using C18 as sorbent, and ethyl acetate and acetonitrile saturated in n-hexane (85:15, v/v) as elution solvent with a simultaneous clean up with Florisil in-line. The QqQ analyzer acquired data in selected reaction monitoring (SRM) mode, permitting both quantification and confirmation in a single injection with a running time reduced up to 17.70 min. Recovery was in the range of 70-110% and 70-106% at 15 and 50 microg/kg, respectively. Precision values expressed as relative standard deviation (RSD) were lower than 20%. Linearity in the range of 10-150 microg/kg provided determination coefficients (R(2)) higher than 0.98 for all compounds. Limits of detection (LODs) for pesticides were < or =2.25 microg/kg and limits of quantification (LOQs) ranged from 0.02 to 7.78 microg/kg. LODs for PCBs were < or =0.41 microg/kg and LOQ were < or =0.71 microg/kg. The method was applied to real samples. Endosulfan sulphate and p,p'-DDE were found in two samples at concentrations below the first calibration level.  相似文献   

5.
The use of a hybrid triple quadrupole-linear ion trap (QqQ(LIT)) mass spectrometer system for a comprehensive study of fragmentation mechanisms is described. The anxiolytic drug, buspirone, was chosen as a model compound for this study. With the advent of a QqQ(LIT) instrument, both the traditional quadrupole and the new linear ion trap scans (LIT) could be performed in a single LC run. In the past, a sample had to be run on two different instruments, namely, a triple quadrupole instrument (QqQ) and a 3D ion trap (3D IT) to obtain similar information. With the new QqQ(LIT) technology, collision-induced dissociation (CID) occur in a quadrupole collision cell, q2, and fragment ions are trapped and analyzed in Q3 operated in LIT mode. In this work, high-sensitivity product ion spectra of buspirone were obtained from the one-stage 'Enhanced Product Ion' scan (EPI) with rich product ions and no low mass cut-off. Furthermore, detailed fragmentation pathways were elucidated by further dissociation of each of the fragment ions in the EPI spectrum using MS(3) mode in the same run. The MS(3) scan was performed by incorporating CID in q2, and trapping, cooling, isolation, and resonance-excitation in Q3 when operating in LIT mode. This approach allowed unambiguous assignment of all fragment ions quickly with fewer experiments and easier interpretation than the previous approach. The overall sensitivity for obtaining complete fragment ion data was significantly improved for QqQ(LIT) as compared with that of QqQ and 3D IT mass spectrometers. This is beneficial for structure determination of unknown trace components. The method allowed structure determination of metabolites of buspirone in rat microsomes at 1 microM concentration, which was a 10-fold lower concentration than was needed for QqQ or 3D IT instruments. The QqQ(LIT) instrument provided a simple, rapid, sensitive and powerful approach for structure elucidation of trace components.  相似文献   

6.
A sensitive and reliable method using pressurized liquid extraction (PLE) and liquid chromatography (LC)/electrospray ionization (ESI) tandem mass spectrometry with a triple quadrupole (QqQ) analyzer has been developed for the analysis of fumonisin B(1) (FB(1)), fumonisin B(2) (FB(2)) and fumonisin B(3) (FB(3)) in corn-based baby foods. Influence of several extraction parameters that affect PLE efficiency such as temperature, pressure, solvent extraction, number of cycles and dispersant/clean-up agents were studied. The selected PLE operating method was: 3g of sample was packed into 11 ml stainless-steel cell and fumonisins were extracted with methanol at 40 degrees C, 34 atm in one cycle of 5 min at 60% flush. The analytes were ionized in ESI operating with positive ion mode and identified by selecting two monitoring transitions, permitting quantification and confirmation in a single injection. Recoveries ranged from 68% to 83% at fortification levels of 200 microg kg(-1) with relative standard deviation (RSD) from 4% to 12%. The limits of quantification were from 2 microg kg(-1) for FB(1) and FB(2), and 5 microg kg(-1) for FB(3), which are below the maximum residue level established by the European Union legislation in infant formulas. The proposed method was successfully applied to the analysis of twenty seven samples of baby food products collected from different markets, and one positive sample with a content of 15.9 microg kg(-1) for FB(1), 9.2 microg kg(-1)for FB(2) and 5.8 microg kg(-1) for FB(3) was obtained. Given the simplicity and potential of the proposed procedure, its application for safety control is recommended.  相似文献   

7.
Two methods for extracting organochlorine (OCs) and organophosphorus (OPs) pesticides from animal liver have been developed. The determination was carried out by gas chromatography with electron impact ionization tandem mass spectrometry (GC-(EI-)MS/MS) using a triple quadrupole (QqQ) analyzer. First, a liquid-solid extraction performed with a high-speed homogenizer (Polytron) using ethyl acetate as solvent, and a subsequent clean-up by gel permeation chromatography (GPC) was applied, determining 34 pesticides. Secondly, a matrix solid phase dispersion (MSPD) extraction with octadecylsilyl (C(18)) sorbent combined with a Florisil clean-up and ethyl acetate elution was performed, analyzing 25 compounds. These methodologies have been tested and compared in the sample pre-treatment due to the fatty nature of the matrix. The GPC method was finally selected and validated, yielding recoveries in the range 70-115%, with precision values expressed as relative standard deviation (RSD) lower or equal to 20%, at the spiking levels of 25 and 50 microg kg(-1), and limits of quantification (LOQs) lower than the maximum residue levels (MRLs) set by the European Union in animal products, except for isofenphos. Linearity was also studied ranging between 5 and 300 microg kg(-1) for most of pesticides. This method was applied to the analysis of real liver samples of chicken, pork and lamb.  相似文献   

8.
In this work, a high repetition rate laser matrix-assisted laser desorption/ionization (MALDI) source is studied on a quadrupole-time-of-flight (QqTOF) and a triple quadrupole (QqQ) mass spectrometer for rapid quantification of small pharmaceutical drugs. The high repetition rate laser allows an up to 100-fold higher pulse frequency as compared with regular MALDI lasers, resulting in much larger sample throughput and number of accumulated spectra. This increases the reproducibility of signal intensities considerably, with average values being around 5% relative standard deviation after taking into account the area ratio of the analyte to an internal standard. Experiments were conducted in MS/MS mode to circumvent the large chemical background due to MALDI matrix ions in the low mass range. The dynamic range of calibration curves on the QqTOF mass spectrometer extended over at least two orders of magnitude, whereas on the QqQ it extended over at least three orders of magnitude. Detection limits ranged from 60-400 pg/microL on the QqTOF and from 6-70 pg/microL on the QqQ for a series of benzodiazepines. The benzodiazepine content of commercial pill formulations was quantified, and less than 5% error was obtained between the present method and the manufacturer's certified values. Furthermore, a high sample throughput was achieved with this method, so that a single MALDI spot could be quantitatively scanned in as little as 15 s, and an entire 96-well MALDI plate in 24 min.  相似文献   

9.
The sequence coverage by fragment ions resulting from collision-induced dissociation in a triple stage quadrupole (TSQ) and a quadrupole ion trap (QIT) mass spectrometer of 10-20-mer oligonucleotides was investigated. While (a-B) and w ion series were the most abundant on both instruments, additional ion series of sequence relevance were preferably formed in the TSQ. Thus, a total number of 83 fragment ions were used to deduce the complete sequence of a 10-mer oligonucleotide of mixed sequence from a tandem mass spectrum recorded on the TSQ. The complete sequence was also encoded in the 28 fragments that were obtained from the QIT under comparable fragmentation conditions. Spectrum complexity increased considerably at the cost of signal-to-noise ratio upon fragmentation of a 20-mer oligonucleotide in the TSQ, whereas spectrum interpretation with longer oligonucleotides was significantly more straightforward in spectra recorded on the QIT. The extent of fragmentation had to be optimized by appropriate setting of collision energy and choice of precursor ion charge state in order to obtain full sequence coverage by fragments for de novo sequencing. Moreover, full sequence information was also dependent on base sequence because of the low tendency of backbone cleavage at thymidines. Tandem mass spectrometry on the QIT yielded redundant information that was successfully utilized to deduce the complete sequence of 20-mer oligonucleotides with high confidence.  相似文献   

10.
A method for simultaneous analysis of about 260 pesticides by gas chromatography coupled to tandem mass spectrometry (GC/MS/MS) with a triple quadrupole analyzer (QqQ) has been studied. The pesticides were extracted with acetonitrile and cleaned up by a bilayer cartridge. A single injection method was developed for the monitoring of all of the targeted pesticides. Two MS/MS transitions were selected for each analyte using the intensity ratio obtained from them as a confirmatory parameter. By using matrix-matched standards, 260 pesticides could be determined in most matrixes with recoveries of 70-120% and a standard deviation of < or = 20 at 2 different fortification levels of 0.02 and 0.1 microg/g. The developed method was applied to the monitoring of 173 agricultural product samples from the local market. The sensitivities of this method were lower than with most of the selective GC detectors, such as flame photometric or single MS. The selectivity of QqQ gives a very clean chromatogram, making compound identification and confirmation easy. The quick and reliable monitoring was achieved by combination with rapid extraction and cleanup.  相似文献   

11.
A new method based on ultra-performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry ((Q-ToF)-MS) was developed for the analysis of 32 biologically active compounds including anti-inflammatories, analgesics, lipid regulators, psychiatric drugs, anti-ulcer agents, antibiotics, beta-blockers and phytoestrogens. This new method allows chromatographic analysis in 14 min, with instrumental detection limits from 2 to 84 pg, and limits of quantification ranging from 0.1 to 15 ng/L in tap water, and from 2 to 300 ng/L in wastewater. The potential of liquid chromatography with triple quadrupole mass spectrometry (LC/QqQ-MS) was compared with that of UPLC/(Q-ToF)-MS for the analysis of biologically active compounds in water samples. LC/Q-ToF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of ToF instruments diminishes the problem of isobaric interferences and helps the analysis of trace compounds in complex samples. In this work UPLC/Q-ToF chromatograms were recorded containing full scan spectral data. The m/z values of analytes were extracted from the total ion chromatogram (TIC) and the accurate masses of the compounds were obtained. In addition, to increase the selectivity of ToF measurements a narrow accurate mass interval (20 m m/z units mass window) was used to reconstruct the chromatographic traces. However, regarding quantitative performance in terms of dynamic range and limits of detection (LODs), typical LODs achieved by QqQ instruments operating in multiple-reaction monitoring (MRM) mode ranged from 1 to 50 ng/L in wastewater, and the linear response for QqQ instruments generally covers three orders of magnitude. This is an important advantage over ToF instruments and one of the reasons why QqQ instruments are widely used in quantitative environmental analysis.  相似文献   

12.
Liquid chromatography ion-trap mass spectrometry LC-MSn has been successfully applied to identify and confirm carbosulfan and seven of its metabolites in oranges after pressurized liquid extraction (PLE) with dichloromethane. Mass spectra of carbosulfan and its metabolites were investigated using multiple stages of mass spectrometry. Although interpretation of the fragmentation pathways, based on mass spectra, enables structural elucidation and identification of these compounds, the proposed fragmentation pathways and ion structures need verification by exact mass measurements. The analytical method--PLE and LC-MS3 --was validated: limits of quantification (LOQ) ranged from 0.01 to 0.07 mg kg(-1); at this level, recoveries were 55-90% with RSDs (five replicate analyses) from 8 to 19%. The degradation of carbosulfan was determined in a laboratory study carried out in mature oranges (Valencia Late) and tangerines (Clementine of Nules) already harvested. Main degradation products of carbosulfan were carbofuran, 3-hydroxycarbofuran, 3-ketocarbofuran and dibutylamine.  相似文献   

13.
Veterinary drugs (VDs) can remain in milk as a consequence of their use in livestock. In order to control the levels of VD residues in milk, screening methodologies can be applied for a rapid discrimination among negative and non-negative samples. In a second stage, non-negative samples are classified as negative or positive samples by using a confirmation method. Pre-target screening methods in low resolution MS (LRMS) are normally applied, but the number of analytes is limited, whereas the information obtained by full scan acquisition in high resolution mass spectrometry (HRMS) is improved. Here, three screening methods (running time<4 min) based on Orbitrap, quadrupole-time of flight (QqTOF) and triple quadrupole (QqQ) have been compared, using in all cases ultra-high performance liquid chromatography (UHPLC). For HRMS, the identification of the VDs was based on retention time (RT) and accurate mass measurements. Confirmation was based on the monitoring of fragments generated without precursor selection. The performance characteristics of the screening method provided reliable information regarding the presence or absence of the compounds below an established value, including uncertainty region and cut-off values. Better results in terms of cut-off values (≤ 5.0 μg kg(-1), except for spiramycin with a cut-off of 13.4 μg kg(-1) for milk samples and 43.1 μg kg(-1) for powdered milk based, emamectin with a cut-off of 42.2 μg kg(-1) for milk samples and doxycycline, with a cut-off value of 15.8 μg kg(-1) in powdered milk-based infant formulae) and uncertainty region were obtained using the Orbitrap-based screening method, which was submitted to further validation and used to analyze different real milk samples. The proposed method can be used in routine analysis, providing reliable results.  相似文献   

14.
The use of liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC-ToF-MS) provides an attractive alternative to liquid chromatography coupled to quadrupole (LC-MS) or triple quadrupole mass spectrometry (LC-MS/MS) in multiresidue analysis. ToF-MS provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. In this work, the influential parameters in time-of-flight detection using an electrospray ionization (ESI) source were studied using a central composite design to obtain the main effects and their two-factor interactions. The method developed uses LC-ESI-ToF-MS to determine and characterize quinolones regulated by the EU in pig liver samples below the maximum residue limits (MRLs). Linearity, decision limit, detection capability, detection and quantification limits, precision and recoveries were determined and adequate results were obtained, with quantification limits between 1.5 and 6 microg kg(-1) and recoveries higher than 60% for all quinolones. Limits of detection are lower than 2 microg kg(-1). Results obtained using LC-ESI-ToF-MS were compared with those obtained using LC coupled to a quadrupole and to triple quadrupole mass spectrometer. The work described in this paper illustrates the suitability and excellent confirmatory potential of LC-ToF-MS for multiresidue analysis in food samples.  相似文献   

15.
In this work, two analytical methods based on liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC/ESI-TOFMS) and tandem mass spectrometry (LC/ESI-MS/MS) are described for the identification, confirmation and quantitation of three insecticides non-authorized in the European Union (nitenpyram, isocarbophos and isofenphos-methyl) but detected in recent monitoring programmes in pepper samples. The proposed methodologies involved a sample extraction procedure using liquid-liquid partition with acetonitrile followed by a cleanup step based on dispersive solid-phase extraction. Recovery studies performed on peppers spiked at different fortification levels (10 and 50 microg kg(-1)) yielded average recoveries in the range 76-100% with relative standard deviation (RSD) (%) values below 10%. Identification, confirmation and quantitation were carried out by LC/TOFMS and LC/MS/MS using a hybrid triple quadrupole linear ion trap (QqLIT) instrument in multiple-reaction monitoring (MRM) mode. The obtained limits of quantitation (LOQs) were in the range 0.1-5 microg kg(-1), depending on each individual technique. Finally, the proposed methods were successfully applied to the analysis of suspected pepper samples.  相似文献   

16.
Ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-QqTOF-MS) is an emerging technique offering more rapid and efficient separation, as well as the possibility to obtain accurate mass measurement and tandem mass spectrometry (MS/MS). This paper deals with the use of UPLC-QqTOF-MS to identify the pesticide residues present in complex pear extracts. Carbendazim, imazalil, and ethoxyquin were successfully identified because of the accurate mass determination of their protonated molecule and their major fragments in the product ion mass spectra. A few plastic and latex additives were also found, most of them probably coming from the packaging transfer to the fruits. The potential of the UPLC-QqTOF-MS and UPLC-QqTOF-MS/MS techniques as a quantification tool is also discussed taking imazalil as example. For quantification, calibration curves were linear over a dynamic range of 2 orders of magnitude, whereas higher calibration ranges are better adjusted to polynomial curves of second and third order. Quantification using different mass windows was also assessed. Accurate quantification required mass windows as wide as 20 mDa, narrower mass windows of 5 mDa provided erroneous quantification, probably because the low ion abundance. The mean recoveries and percentage relative standard deviation (RSD) of 35 determinations for imazalil were 76% (13% RSD) by MS and 77% (14% RSD) by MS/MS. The theoretical limit of detection was 0.4 microg kg(-1), with a validated limit of quantification of 2 microg kg(-1). The quantitative data obtained using UPLC-QqTOF-MS were compared with those obtained using conventional liquid chromatography (LC)-MS/MS with a triple quadrupole (QqQ). It was concluded that UPLC-QqTOF-MS might become a powerful analytical tool for both, unknown's identification and quantification of target pesticides.  相似文献   

17.
An API 3000 triple-quadrupole instrument and a QSTAR Pulsar quadrupole time-of-flight (TOF) mass spectrometer were compared for the determination of phosphopeptides by precursor ion scanning in both the positive and negative nanoelectrospray ionization modes. The limits of detection for synthetic phosphopeptides were similar (500 amol microl(-1)) for both types of instruments when monitoring precursors of -79 Da (PO(3)(-)). However, the quadrupole TOF system was approximately fivefold more sensitive (1 fmol microl(-1)) than the triple-quadrupole instrument (5 fmol microl(-1)) when monitoring precursors of 216 Da (immonium ion of phosphotyrosine). The recently introduced Q(2)-pulsing function, which enhances the transmission of fragment ions of a selected m/z window from the collision cell into the TOF part, improved the sensitivity of precursor ion scans on a quadrupole TOF instrument. The selectivity of precursor ion scans is much better on quadrupole TOF systems than on triple quadrupoles because the high resolving power of the reflectron-TOF mass analyzer permits high-accuracy fragment ion selection at no expense of sensitivity. This minimizes interferences from other peptide fragment ions (a-, b-, and y- type) of the same nominal mass but with sufficient differences in their exact masses. As a result, the characteristic immonium ion of phosphotyrosine at m/z 216.043 can be utilized for the selective detection of tyrosine phosphorylated peptides. Our data suggest that, in addition to their superior performance for peptide sequencing, quadrupole TOF instruments also offer a very viable alternative to triple quadrupoles for precursor ion scanning, thus combining high sensitivity and selectivity for both MS and MS/MS experiments in one instrument.  相似文献   

18.
In this work, we have developed a sensitive method for detection and quantification of eight N-nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosomorpholine (NMor), N-nitrosomethylethylamine (NMEA), N-nitrosopirrolidine (NPyr), N-nitrosodiethylamine (NDEA), N-nitrosopiperidine (NPip), N-nitroso-n-dipropylamine (NDPA) and N-nitrosodi-n-butylamine (NDBA) in drinking water. The method is based on liquid chromatography coupled to tandem mass spectrometry, using atmospheric pressure chemical ionization (APCI) in positive mode with a triple quadrupole analyzer (QqQ). The simultaneous acquisition of two MS/MS transitions in selected reaction monitoring mode (SRM) for each compound, together with the evaluation of their relative intensity, allowed the simultaneous quantification and reliable identification in water at ppt levels. Empirical formula of the product ions selected was confirmed by UHPLC-(Q)TOF MS accurate mass measurements from reference standards. Prior to LC-MS/MS QqQ analysis, a preconcentration step by off-line SPE using coconut charcoal EPA 521 cartridges (by passing 500 mL of water sample) was necessary to improve the sensitivity and to meet regulation requirements. For accurate quantification, two isotope labelled nitrosamines (NDMA-d(6) and NDPA-d(14)) were added as surrogate internal standards to the samples. The optimized method was validated at two concentration levels (10 and 100 ng L(-1)) in drinking water samples, obtaining satisfactory recoveries (between 90 and 120%) and precision (RSD<20%). Limits of detection were found to be in the range of 1-8 ng L(-1). The described methodology has been applied to different types of water samples: chlorinated from drinking water and wastewater treatment plants (DWTP and WWTP, respectively), wastewaters subjected to ozonation and tap waters.  相似文献   

19.
Gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) is one of the most powerful techniques in pesticide residue analysis. MS/MS can be conceived in two ways: tandem in space (e.g. triple quadrupole, QqQ) or in time (e.g. ion trap, IT). QqQ and IT are commonly interfaced to GC; however, there has not been any direct comparison between them in pesticide residue analysis so far. In the present work, the performance of GC coupled to these two analyzers (GC-QqQ-MS/MS and GC-IT-MS/MS) was studied and compared for pesticide residue analysis as well as its application in food analysis. The large volume injection (LVI) technique together with programmed-temperature vaporization (PTV) was applied. For this purpose, 19 pesticides, including organochlorine and organophophorus pesticides and pyrethroids, were analyzed in both systems. Mass spectrometric data, performance characteristics (linearity, intra-day and inter-day precision) and the influence of the matrix nature on the analysis of low concentrations were compared. The target compounds were analyzed in solvent and in two representative food matrices such as cucumber (high water content) and egg (high fat content). MS data and intra-day precision were similar in QqQ and IT, whereas inter-day precision was significantly worse in QqQ. Linearity (expressed as determination coefficient, R(2)) in the range 10-150mugL(-1) was adequate in both systems; however, better R(2) values were obtained with the QqQ analyzer in high and low concentration ranges (1-50 and 1-750mugL(-1), respectively). The influence of the matrix nature on the analysis of low concentrations of each analyzer was also evaluated. The QqQ and IT performance was similar in cucumber and solvent. However, QqQ provided better sensitivity in egg working in selected reaction monitoring (SRM).  相似文献   

20.
This article describes the development of an enhanced liquid chromatography-mass spectrometry (LC-MS) method for the analysis of pesticides in olive oil. One hundred pesticides belonging to different classes and that are currently used in agriculture have been included in this method. The LC-MS method was developed using a hybrid quadrupole/linear ion trap (QqQ(LIT)) analyzer. Key features of this technique are the rapid scan acquisition times, high specificity and high sensitivity it enables when the multiple reaction monitoring (MRM) mode or the linear ion-trap operational mode is employed. The application of 5 ms dwell times using a linearly accelerating (LINAC) high-pressure collision cell enabled the analysis of a high number of pesticides, with enough data points acquired for optimal peak definition in MRM operation mode and for satisfactory quantitative determinations to be made. The method quantifies over a linear dynamic range of LOQs (0.03-10 microg kg(-1)) up to 500 microg kg(-1). Matrix effects were evaluated by comparing the slopes of matrix-matched and solvent-based calibration curves. Weak suppression or enhancement of signals was observed (<15% for most-80-of the pesticides). A study to assess the identification criteria based on the MRM ratio was carried out by comparing the variations observed in standard vs matrix (in terms of coefficient of variation, CV%) and within the linear range of concentrations studied. The CV was lower than 15% when the response observed in solvent was compared to that in olive oil. The limit of detection was < or =10 microg kg(-1) for five of the selected pesticides, < or =5 microg kg(-1) for 14, and < or =1 microg kg(-1) for 81 pesticides. For pesticides where additional structural information was necessary for confirmatory purposes-in particular at low concentrations, since the second transition could not be detected-survey scans for enhanced product ion (EPI) and MS3 were developed.  相似文献   