首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Amino acids in biological fluids have previously been shown to be detectable using liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) with perfluorinated acids as ion-pairing agents. To date, these studies have used precursor mass, retention time and tandem mass spectrometry (MS/MS) to identify and quantify amino acids. While this is a potentially powerful technique, we sought to adapt the method to time-of-flight (TOF)MS. A new application of a recently described liquid chromatographic separation method was coupled with TOFMS to employ accurate mass for qualitative identification; resulting in additional qualitative data not available with standard single quadrupole data. In the current study, we evaluated 25 physiological amino acids and one dipeptide that are routinely quantified in human plasma. Accuracy and precision of the method was evaluated by spiking human plasma with a mix of the 25 amino acids; in addition, the inclusion of a cation-exchange cleanup step was evaluated. The calibration curves were linear over a range from 1.56 to 400 microM. The dynamic range was found to be within physiological levels for all amino acids analyzed. Accuracy and precision for most of the amino acids was between 80-120% spike recovery and <10% relative standard deviation (RSD). The LC/MS technique described in this study relies on mass accuracy and is suitable for the quantitation of free amino acids in plasma.  相似文献   

2.
The aim of this work was to develop a method for the characterization and determination of diuretics in human urine samples by liquid chromatography (LC) coupled to pneumatically assisted electrospray ionization (ES) mass spectrometry (MS). The diuretics studied were substances forbidden by the IOC such as trichlormethiazide, furosemide, canrenoic acid, benzthiazide, bendroflumethiazide, bumetanide, etacrynic acid and spironolactone. For this purpose, the operational parameters of electrospray, such as counter electrode voltage, capillary voltage, sample cone voltage and source temperature, were optimized in order to obtain the best signal stability and the highest sensitivity for the greatest number of diuretic agents. The optimized separation method was successfully coupled with the MS system to analyze the above-mentioned diuretics extracted from spiked urine samples by a liquid extraction and clean-up procedure at basic pH, using ethyl acetate as solvent and the salting-out effect (NaCl). The mass spectra obtained provide adequate information for identification purposes. Positive urine samples obtained from athletes were also analyzed. The presence of these substances in human urine was confirmed by this method, making LC/ES-MS an analytical tool to be considered in the area of antidoping control.  相似文献   

3.
A pneumatically assisted electrospray liquid chromatography/mass spectrometry (LC/MS) interface has been modified for use with packed-column supercritical fluid chromatography (pcSFC). The modifications include the addition of a concentric sheath-flow liquid to the spray device. This allowed the addition of modifiers at the sprayer tip that promote ionization of neutral, pcSFC-separated components. Post-column chromatographic fidelity was preserved using a novel pressure-regulation scheme. Post-column pressure regulation was accomplished by adding a “pressure-regulating fluid” (supplied under pressure control) to the effluent just ahead of the sprayer. The modified interface has been used to characterize a variety of mixtures including emollients, modified polysiloxanes, and pharmaceutical agents. The spectra produced by using this pcSFC/MS interface are similar to electrospray LC/MS spectra.  相似文献   

4.
Electrospray ionization mass spectrometry was applied to the study of the amines IQ, Trp-P-1, Trp-P-2, PhIP and AC and the co-mutagens harman and norharman. The results obtained on a triple quadrupole mass spectrometer equipped with a pneumatically assisted electrospray source are reported. The chromatographic conditions were optimized with a reversed-phase column (1 mm I.D.) using acetonitrile-5 mM ammonium acetate (pH 6.7) (50:50) as the mobile phase at a flow-rate of 50 μl min−1. Different parameters influencing the mass spectra were investigated. For these compounds [M + H]+ in the positive-ion mode and also some fragments produced through collisionally activated decomposition in the interface were observed. Detection limits of 5.4–44 pg were obtained for standard solutions of these amines. Analysis of a meat extract was performed by HPLC-MS using single-ion monitoring after a solid-phase extraction clean-up.  相似文献   

5.
Pneumatically-assisted electrospray tandem mass spectrometry (ES MS/MS) was proposed as a technique for the identification of dimethylarsinoyl-riboside derivatives (arsenosugars) in seaweed (Laminaria). Conditions for the acquisition of MS and MS/MS spectra were optimized. A size-exclusion HPLC (SE HPLC) step was developed for the purification of algal extracts prior to ES MS. The arsenosugar fraction was found to elute prior to the majority of other arsenic compounds. The identity of the compounds expected to be arsenosugar compounds was confirmed by the collision induced dissociation (CID) of the relevant protonated molecule ions. An independent confirmation of the identity of analytes was obtained by two-dimensional (size-exclusion–anion exchange) HPLC–ICP MS with signal identification by spiking with the appropriate arsenosugar standards.  相似文献   

6.
Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.  相似文献   

7.
Jeong JS  Kim SK  Park SR 《Electrophoresis》2012,33(14):2112-2121
A high durability sheathless electrospray ionization interface of CE-MS is applied for the sensitive analysis of underivatized amino acids. The sheathless interface was realized using an ionophore membrane-packed electro-conduction channel. The interface functioned well with a volatile alkaline background electrolyte (BGE) and uncoated fused-silica capillaries for CE-MS analysis of underivatized amino acids. High electroosmotic flow with alkaline BGE facilitated high separation efficiency (>100,000 theoretical plates) and short analysis time (<15 min). Both the short-term stability and long-term durability are particularly suited for routine applications. Using electrokinetic injection and the multiple reaction monitoring (MRM) mode with a triple-quadrupole analyzer, high sensitivity was achieved, which yielded detection limits of 0.05-0.81 μM. For the quantitation of underivatized amino acids, quantification precisions (RSDs) for intra- and inter-day analyses were less than 3%. Recoveries from serum were 96.3-101.8% for isotope dilution mass spectrometry (IDMS). When compared with HPLC-IDMS for human serum samples, highly agreeable (96.9-102.0%) results were obtained with the proposed CE-IDMS method.  相似文献   

8.
An ion-pairing liquid chromatography/electrospray tandem mass spectrometry (LC/ES-MS/MS) method with in vivo microdialysis for the determination of amphetamine in rat brain has been developed. A microdialysis probe was surgically implanted into the striatum of the rat and artificial cerebrospinal fluid (aCSF) was used as the perfusion medium. Samples were collected and then analyzed off-line by LC/ES-MS/MS. A reversed-phase C18 column was employed for LC separation and MS/MS was utilized for detection. Trifluoroacetic acid (TFA) was added to the mobile phase (acetonitrile/water) as an ion-pairing reagent. Detection was by ES-MS/MS directly, and no post-column addition of organic modifier was needed. Dual linear ranges were determined from 0.1-0.5 microg/mL and 0.005-0.1 microg/mL, respectively. The detection limit, based on a signal-to-noise ratio of 3, was 0.001 microg/mL (5 nM). Good precision and accuracy were obtained. The applicability of this newly developed method was demonstrated by continuous monitoring of amphetamine concentrations in rat brain. Amphetamine reached a maximum concentration of 0.086 +/- 0.017 microg/mL over 20-40 min after a single 3.0 mg/kg intraperitoneal administration.  相似文献   

9.
Several organophosphate triesters are widely used as flame retardants and can be metabolized to dibutyl (DBP), diphenyl (DPhP), di(2-ethylhexyl) (DEHP) and di(1,3-dichloro-2-propyl) (or bis(1,3-dichloro-2-propyl); DDCPP) phosphoric acid, respectively. A highly sensitive liquid chromatography-electrospray ionization(+)-triple quadrupole mass spectrometry (LC-ESI(+)-QQQ-MS/MS) based analysis method was presently developed. In this method the target compounds were separated with a C(18)-based reversed phase LC column, and decamethonium hydroxide (dicatonic reagent) was introduced post-LC to form ion-pairs, which were subsequently detected by ESI(+). For the phosphate acid diester ion-pairs, the mass spectra showed the most abundant ion to be [(CH(3))(2)N(CH(2))(10)N(CH(3))(3)](+), with lesser abundances of [[M-H](-)[(CH(3))(3)N(CH(2))(9)CH(2)](2+)](+) and [CH(2)CH(CH(2))(8)N(CH(3))(3)](+). For DDCPP, the fragment ions of [[Cl](-)[(CH(3))(3)N(CH(2))(10)N(CH(3))(3)](2+)](+) and [[Cl](-)[(CH(3))(3)N(CH(2))(9)CH(2)](2+)](+) could also be observed. The limits of quantitation (LOQs) by LC-ESI(+)-MS/MS (based on multiple reaction monitoring) were 0.14, 0.03, 0.14 and 0.02 ng/mL for DPhP, DBP, DDCPP and DEHP, respectively. The response was highly linearly correlated (r>0.995) with concentration over the range of the LOD to 1000 ng/mL. The matrix effect on ESI+ was negligible for the samples in experiment of in vitro metabolism using rat liver microsomes.  相似文献   

10.
Oligomannuronic acids and oligoguluronic acids were prepared by enzymatic hydrolysis of alginate with alginate lyases. The oligosaccharides generated up to degree of polymerization 16 were characterized by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) and electrospray ionization mass spectrometry (ESI-MS). Acetate buffer linear gradients were used as mobile phases for separations of oligosaccharides. ESI-MS and HPAEC-PAD are very effective for the analysis and characterization of anionic oligosaccharides.  相似文献   

11.
Amino acid formamidene butyl esters are optimally prepared by heating amino acids with dimethylformamide dimethylacetal (DMF-DMA) for 2 minutes at 65 degrees C and then with n-butanol/hydrogen chloride for 15 minutes at 65 degrees C. The formamidene butyl esters of simple alpha-amino acids and beta-amino acids afford between 1.1 and 20 times the signal intensity of the corresponding butyl esters during electrospray ionization tandem mass spectral analysis. Complex alpha-amino acids, such as ornithine, arginine and citrulline, and gamma-amino acids are better analyzed as butyl esters. Secondary alpha-amino acids, such as proline and sarcosine, give a mixture of two iminium salts with the DMF-DMA derivatization method. A derivative incorporating two molecules of the amino acid predominates at higher derivatization temperatures. Contrary to a previous report, N-formylamino acids were not detected. The presence of secondary amino acids in amino acid mixtures, derivatized as formamidene butyl esters, affords derivatives that incorporate two different amino acids. The new formamidene butylation method is unlikely to replace the butylation procedure used by neonatal blood spot screening programs for amino acid disorders, since a much poorer response was obtained with formamidene butyl esters of arginine and citrulline, important in the diagnosis of arginase deficiency and citrullinaemia.  相似文献   

12.
With the introduction of a diisopropyloxyphosphoryl (DIPP) group at the N-terminus of amino acids, the signal response in electrospray ionization mass spectrometry can be enhanced by 10-100-fold in positive mode and even more in negative mode. An enhancement of proton affinity due to the N-terminal DIPP derivatization was considered to be responsible for the sensitivity improvement in positive mode, which was supported by kinetic method studies. Two possible mechanisms, i.e., an increase in gas-phase acidity due to the introduction of the electron-withdrawing DIPP group, and the effect of pH on the formation of anions of amino acids and their phosphorylated derivatives, were considered for the signal response enhancement in negative mode.  相似文献   

13.
Triptorelin, a synthetic peptide hormone used in the treatment of prostate cancer by means of reduction in the action of male hormone testosterone, is studied here. The synthetic procedure commonly results in unwanted side products that require extensive purification and characterization of the synthesis mixture. The chromatographic separation of triptorelin from the crude mixture was developed by applying the linear solvation energy relationship (LSER) methodology previously developed, to optimize the composition of the mobile phase in order to avoid lengthy empirical optimization procedures. Electrospray ionization mass spectrometry coupled to liquid chromatography (LC/ES-MS) was used to obtain reliable information on the inevitable side products. The knowledge of the identity of these impurities allows fast optimization of the synthetic procedure and also the therapeutic use of triptorelin peptide hormone.  相似文献   

14.
The negative-ions of N-phosphoryl amino acids were studied by electrospray ionization tandem mass spectrometry (ESI-MS/MS). The negative-ion ESI-MS/MS of N-phosphoryl amino acids showed characteristic fragmentation patterns different from those observed in the corresponding positive-ion ESI-MS/MS and negative-ion fast-atom bombardment mass spectra. For negative-ion ESI-MS/MS, a unique fragmentation from the N-terminal of N-phosphoryl amino acids or peptides containing a free beta-OH or CO(2)H group was observed to yield the characteristic fragment ion (RO)(2)P(O)O(-). The ease of the rearrangement depended on the position of the hydroxyl group in amino acids or peptides, and the N --> O rearrangement mechanism was proposed to involve the participation of the hydroxyl group. From previous solution-phase experiments and theoretical calculations, it was found that the beta-OH group was more active than gamma-OH, and the corresponding difference in negative-ion ESI-MS/MS was consistent with those previous findings.  相似文献   

15.
16.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

17.
Ion-pairing high performance liquid chromatography (IP-HPLC) was utilized to monitor the composition changes of blue gel pen ink entries on paper stored in different light conditions and natural environment. The chromatographic conditions were optimized by comparing the separation efficiencies of the blue gel pen inks using a series of ion-pairing reagents, including ammonium carbonate, ammonium acetate, triethylamine acetate, tributylamine acetate, tetrabutylammonium bromide and dihexylammonium acetate. It has been found that tributylamine acetate was a suitable ion-pairing reagent for separation of the inks on the common C18 column. The analysis results of the ink entries on paper in different aging conditions showed that the tendency of composition change in natural aging condition was similar with those in fluorescent light and UV light conditions, respectively. One main component dye of the blue gel pen ink, Acid Blue 9, and its degradation products were identified by ion-pairing high performance liquid chromatography coupled with electrospray tandem mass spectrometry. The results showed that the main degradation products originated from the Acid Blue 9. It gave a reasonable explanation for the changing rules of the relative content of the dyes in the blue gel pen ink. The results obtained can provide scientific evidences for dating of the blue gel pen ink entries on documents.  相似文献   

18.
A rapid and sensitive LC/electrospray ionization-MS/MS method has been developed for the determination of dodine in fruit samples. Based on a liquid-liquid extraction of 10 g solid fruit homogenate using an acetone-dichloromethane-hexane mixture and acetate ammonium buffer (pH 4.5), this LC/MS/MS procedure was characterized by recoveries above 50%, with good intra-assay precision (RSD < 13%) and interassay precision (RSD < 18%) for seven different matrixes (apple, apricot, cherry, peach, pear, plum, and quince). This method was validated from 5 to 500 microg/kg according to standard guidelines. Its LOD (1 microg/kg) and LOQ (5 microg/kg) were in accordance with recommendations of the European legislation defined for infant food [maximum residue level (MRL) = 10 microg/kg]. The whole procedure was finally tested on 1022 fruit samples intended for commercialization, both infant food samples and samples not intended in particular for babies. In this study, dodine was detected in 27 samples; none exhibited a concentration higher than the MRL.  相似文献   

19.
A method has been developed and is described for the quantitative determination of a nonpeptide antithrombotic in dog plasma. The assay employs reversed phase microbore high-performance liquid chromatography in conjunction with tandem mass spectrometry utilizing pneumatically assisted electrospray ionization. The analyte and internal standard are isolated from the plasma matrix by solid-phase extraction. The mass spectrometer is operated in the positive ion multiple reaction monitoring mode and is set to detect the presence of a precursor-product ion pair for both the analyte and internal standard to generate product ion chromatograms for both species. The analyte is quantified by using weighted least-squares regression of the peak height ratio of drug:internal standard. The method provides linear response for plasma concentrations ranging from 5 ng/mL (25 pg on-column) to 2500 ng/mL. Statistical evaluation and examples of authentic sample assays are also presented.  相似文献   

20.
The analytical performances of two triple-quadrupole instruments, which differ in their atmospheric-pressure sources, were evaluated for native amino acid analysis. The Applied Biosystems/Sciex API 300 instrument was equipped with a turboIon Spray source and a curtain gas interface while the Waters/Micromass Quattro Ultima instrument was characterized by its Z-spray source. Liquid chromatography/mass spectrometry analysis of native amino acids requires volatile ion-pairing mobile phase additives (mainly perfluorinated carboxylic acids). The effects of the structure and concentration of the ion-pairing reagents as well as the organic modifier percentage on the electrospray response of amino acids were studied in detail. The most favourable chromatographic conditions depend strongly on the mass spectrometer used. Several instrumental parameters were also studied, including spray voltage, transmission lens voltages, temperature of desolvation and auxiliary gas flow rates. The results show substantial qualitative differences depending on the instrument geometry. The quantitative performances of the two triple-quadrupole mass spectrometers were evaluated in terms of limits of detection and quantification. The effects of the matrix on the analyte ionization were also examined, and the long-term stability of the electrospray performance was studied over 12 h using a mobile phase containing the perfluorinated ion-pairing reagents. The study provides information on the robustness of the MS instrument and its detection sensitivity towards native amino acid analysis. It appears that each instrument has its good and bad points since one provides higher sensitivity while another is more robust.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号