首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 712 毫秒
1.
Enantioseparations of fourteen dansyl amino acids were achieved by using a positively-charged single-isomer beta-cyclodextrin, mono-(3-methyl-imidazolium)-beta-cyclodextrin chloride, as a chiral selector. Separation parameters such as buffer pH, selector concentration, separation temperature, and organic modifier were investigated for the enantioseparation in order to achieve the maximum possible resolution. Chiral separation of dansyl amino acids was found to be highly dependent on pH since the degree of protonation of these amino acids can alter the strength of electrostatic interaction and/or inclusion complexation between each enantiomer and chiral selector. In general, the chiral resolution of dansyl amino acids was enhanced at higher pH, which indicates that the carboxylate group on the analytes may interact with the imidazolium group of cationic cyclodextrin. For most analytes, a distinct maximum in enantioresolution was obtained at pH 8.0. Moreover, the chiral separation can be further improved by careful tuning of the separation parameters such as higher selector concentration (e.g. 10 mM), lower temperature, and addition of methanol. Enantioseparation of a standard mixture of these dansyl amino acids was further achieved in a single run within 30 min.  相似文献   

2.
Three chiral stationary phases were prepared by dynamic coating of sulfobutylether‐β‐cyclodextrin (SBE‐β‐CD) with different degrees of substitution, onto strong anion‐exchange stationary phases. The enantioselective potential and stability of newly prepared chiral stationary phases were examined using a set of structurally different chiral analytes. Measurements were performed in RP‐HPLC. Mobile phases consisted of methanol/formic acid, pH 2.10, and methanol/10 mM ammonium acetate buffer, pH 4.00, in various volume ratios. SBE‐β‐CDs with degrees of substitution (DS) 4, 6.3, and 10 proved suitable for the enantioseparation of 14, 11, and 8 analytes, respectively. The SBE‐β‐CD DS 4 based chiral stationary phase enabled the enantioseparation of the nearly all basic and neutral compounds. Chiral stationary phases with higher sulfobutylether‐β‐cyclodextrin substitution (especially DS 10) yielded higher enantioresolution values for acidic compounds.  相似文献   

3.
A sensitive method for enantioseparation of a basic drug rivastigmine and determination of its optical impurityby capillary electrophoresis with highly sulfated β-cyclodextrin(HS-β-CD)as the chiral selector is described.Ingeneral,enantioseparation of basic chiral compounds is carried out in acidic condition(pH 2.5)to prevent analytesfrom adsorption on the capillary wall.However,in the case of rivastigmine,the detection sensitivity was too limitedto determine the optical impurity of S-rivastigmine lower than 1% when buffer pH was 2.5.It was found that thedetection sensitivity was improved 1.6 times just by raising the buffer pH value from 2.5 to 5.8.The poor columnefficiency due to the adsorption of the analytes on the capillary wall was resolved by using dynamical coating of thecapillary wall with the linear polyacrylamide solution.The experirnental parameters such as the concentration ofHS-β-CD,buffer pH and buffer ionic strength were optimized,respectively.The method was validated in terms ofrepeatability,linearity,limit of detection(LOD)and limit of quantitation(LOQ).Using the present method,the op-tical purity of nonracemic rivastigmine with the enantiomeric excess(ee)value of 99.14% was determined.  相似文献   

4.
Tang W  Muderawan IW  Ong TT  Ng SC 《Electrophoresis》2005,26(16):3125-3133
A novel single-isomer positively charged beta-cyclodextrin (beta-CD), mono-6(A)-butylammonium-6(A)-deoxy-beta-cyclodextrin tosylate (BuAM-beta-CD), has been synthesized, characterized, and used for the enantioseparations of alpha-hydroxy acids, carboxylic acids, and ampholytic analytes by capillary electrophoresis in acidic aqueous background electrolytes. The effective mobilities of all studied analytes decreased with increasing concentration of CD. Satisfactory resolutions were obtained for alpha-hydroxy acids over a wide range of chiral selector concentration. The optimum CD concentration was lower than 5 mM for the carboxylic acids, while higher than 20 mM for alpha-hydroxy acids. Inclusion complexation in combination with ion pair interaction seemed to account for the chiral discrimination process. The hydrogen bonding may provide secondary contribution for the chiral resolution of alpha-hydroxy acids. In addition, BuAM-beta-CD was further proved to be an effective chiral selector for anionic analytes by the baseline enantioseparation of a six-acid mixture within 20 min.  相似文献   

5.
In the past decade, more than 100 different cathinone derivatives slopped over entire Europe due to their enormous popularity. Generally, these novel psychoactive substances are easily available via the internet. This fact leads to various social problems, since cathinones are substances with consciousness‐changing effects and are mainly misused for recreational matters by their consumers. Cathinones possess a chiral center including two enantiomeric forms with potentially different pharmacological behavior. This fact makes analytical method development regarding their chiral separation indispensable. In this study, a chiral capillary zone electrophoresis method for the enantioseparation of 61 cathinone and pyrovalerone derivatives was developed by means of four different β‐cyclodextrin derivatives. As chiral selectors, native β‐cyclodextrin as well as three of its derivatives namely acetyl‐β‐cyclodextrin, 2‐hydroxypropyl‐β‐cyclodextrin, and carboxymethyl‐β‐cyclodextrin were used. The cathinone and pyrovalerone derivatives were either purchased in internet stores or seized by police. As a result, overall 58 of 61 studied substances were partially or baseline separated by at least one of the four chiral selectors using 10 mM of β‐cyclodextrin derivative in a 10 mM sodium phosphate buffer (pH 2.5). Furthermore, the method was found to be suitable for simultaneous enantioseparations, for enantiomeric purity checks and to differentiate between positional isomers. Moreover, an intra‐ and an interday validation was performed successfully for each chiral selector to prove the robustness of the method.  相似文献   

6.
The highly sulfated gamma-CD (HS-gamma-CD) is a chiral selector widely used in CE for the enantioseparation of pharmaceutical compounds. This paper investigated different approaches to reduce the stereoselective analysis time of amphetamine (AT) derivatives according to the chiral selector concentration in the BGE. With high HS-gamma-CD concentration, tested analytes were separated in 3.5 min as anionic complexes with short-end injection technique in reversed polarity mode. However, this procedure presented some limitations in terms of efficiency and resolution, excessive Joule heating and poor compatibility with MS detection. With low HS-gamma-CD concentration, compounds were separated as cations. Conventional approaches to reduce CE analysis time demonstrated critical resolution between some analytes. Therefore, the use of the partial-filling technique compatible with MS detection was carried out. Under optimized conditions, the analysis time for the chiral separation of seven AT like compounds was reduced to 6 min. Moreover, sensitivity of CE-MS was sufficient for the determination of ATs in plasma following a simple liquid-liquid extraction.  相似文献   

7.
Lin X  Zhu C  Hao A 《Electrophoresis》2005,26(20):3890-3896
The resolving ability of 2-O-(2-hydroxybutyl)-beta-CD (HB-beta-CD) with different degrees of substitution (DS = 2.9 and 4.0) as a chiral selector in CZE is reported in this work. Fourteen chiral drugs belonging to different classes of compounds of pharmaceutical interest such as beta-agonists, antifungal agents, ageneric agents, etc., were resolved. The effects of the DS of HB-beta-CD on separations were also investigated. The chiral resolution (R(s)) was strongly influenced by the concentrations of the CD derivative, the BGE, and the pH of the BGE. Under the conditions of 50 mmol/L Tris-phosphate buffer at pH 2.5 containing 5 mmol/L HB-beta-CD, all 14 analytes were separated. The very low concentration necessary to obtain separation was particularly impressive. The DS had a significant effect on the resolution of the chiral drugs and the ionic strength of the separation media; hence, the use of a well-characterized CD derivative is crucial.  相似文献   

8.
A chiral selector, di-n-amyl L-tartrate-boric acid complex, was in situ synthesized by the reaction of di-n-amyl L-tartrate with boric acid in a nonaqueous background electrolyte (BGE) using methanol as the medium. And a new method of chiral nonaqueous capillary electrophoresis (NACE) was developed with the complex as the chiral selector. It has been demonstrated that the chiral selector is suitable for the enantioseparation of some β-blockers and β-agonists in NACE. Some chiral analytes that could not be resolved in aqueous microemulsion electrokinetic chromatography (MEEKC) with the same chiral selector obtained baseline resolutions in the NACE system. The enantioseparation mechanism was considered to be ion-pair principle and the nonaqueous system was more favorable for the ion-pair formation which is quite useful for the chiral recognition. The addition of a proper concentration of triethylamine into the BGE to control the apparent pH (pH*) enhanced the enantiomeric discrimination. In order to achieve a good enantioseparation, the effects of di-n-amyl L-tartrate and boric acid concentration, triethylamine concentration, applied voltage, as well as capillary length were investigated. Under the optimum conditions, all of the tested chiral analytes including six β-blockers and five β-agonists were baseline resolved.  相似文献   

9.
Baseline separation of ten new substituted [1-(imidazo-1-yl)-1-phenylmethyl)] benzothiazolinone and benzoxazolinone derivatives, with one chiral center, was achieved by CD-EKC using highly sulfated CDs (alpha, beta, gamma highly S-CDs) as chiral selectors. The influence of the type and concentration of the chiral selectors on the enantioseparations was investigated. The highly S-CDs exhibit a very high enantioselectivity power since they allow excellent enantiomeric resolutions compared to those obtained with the neutral CDs. The enantiomers were resolved with analysis times inferior to 2.5 min and resolution factors R(s) of 3.73, 3.90, 1.40, and 4.35 for compounds 1, 2, 3, and 5, respectively, using 25 mM phosphate buffer at pH 2.5 containing either highly S-alpha-CD, highly S-beta-CD, and highly S-gamma-CD (3 or 4% w/v) at 298 K, with an applied field of 0.30 kV/cm. The determination of the enantiomer migration order for the various analytes and the study of the analyte structure-enantioseparation relationships display the high contribution of the interactions between the analytes phenyl ring and the CDs to the enantiorecognition process. The thermodynamic study of the analyte-CD affinities permits us to improve our knowledge about the enantioseparation mechanism.  相似文献   

10.
Chen J  Du Y  Zhu F  Chen B 《Journal of chromatography. A》2010,1217(45):7158-7163
Several chiral reagents including cyclodextrins (CDs) and derivatives, crown ethers, proteins, chiral surfactants and polymers have been involved in dual selector systems for enantioseparation of a series of chiral compounds by capillary electrophoresis (CE). In comparison to the chiral reagents above-mentioned, there is no report concerning the use of polysaccharides in dual chiral CE system. In this paper we first investigate the enantioselectivity of polysaccharide-based dual selector systems towards some chiral drugs. During our recent work, glycogen belonging to the class of branched polysaccharides has been used as a novel chiral selector in CE. In this study, three glycogen-based dual chiral CE systems have been established for enantiomeric separations of several racemic basic drugs consisting of duloxetine, cetirizine, citalopram, sulconazole, laudanosine, amlodipine, propranolol, atenolol and nefopam. These three dual systems combined glycogen (neutral polysaccharide) with chondroitin sulfate A (CSA, ionic polysaccharide), β-CD and HP-β-CD, respectively. It was found that the dual system of glycogen/CSA exhibited good enantioselective properties toward the tested drugs. More importantly, compared to the single selector systems, synergistic effect was observed when glycogen was used with CSA for most of the analytes. This indicated the enhancement of enantioseparation observed for these analytes in glycogen/CSA system might be due to some favorable interaction effects between glycogen and CSA. Moreover, in order to evaluate the stereoselectivity of glycogen/CSA, the influences of buffer pH and selector concentration on enantioseparation of the studied drugs were also investigated.  相似文献   

11.
On-line combination of partial filling capillary electrophoresis and electrospray ionization mass spectrometry was demonstrated for the simultaneous enantioseparation of tramadol and its main phase I metabolites. The partial filling technique was efficient at avoiding MS contamination by the chiral selector. Different experimental factors were investigated, including the chiral selector nature and concentration, plug length as well as the separation temperature. The best enantioseparation of the investigated compounds was achieved with a coated polyvinyl alcohol capillary and a 40 mM ammonium acetate buffer, pH 4.0, adding sulfobutyl ether beta-cyclodextrin (2.5 mg/ml) as the chiral selector. The charged cyclodextrin not only allowed enantioseparation of tramadol and its metabolites, but also improved the selectivity of compounds with the same molecular mass. Finally, CE-electrospray ionisation-MS was successfully applied to the stereoselective analysis of tramadol and its main metabolites in plasma after a simple liquid-liquid extraction.  相似文献   

12.
This paper describes an improved access to mono‐6A‐aminoethylamino‐β‐CD (β‐CDen), a very efficient cationic chiral selector for CZE in the separation of eight chiral aromatic vicinal diols. The β‐CDen concentration has a strong influence on the efficiency of enantioseparation. The effects of the pH and concentration of the BGE, the capillary temperature, and the applied voltage on the resolution and separation selectivity have been studied. Excellent chiral resolution was achieved under the optimal conditions of β‐CDen 10 mM, pH 10, 200 mM borate buffer at 15 kV and 20°C within 20 min. Moreover, the developed method was successfully applied to the determination of the enantiomeric purity of the catalytic asymmetric dihydroxylation (AD) reaction products.  相似文献   

13.
Nine racemic arylglycine amides were synthesized and successfully enantioseparated by capillary electrophoresis (CE) using highly sulfated beta-cyclodextrin (HS-beta-CD) as a chiral selector. Baseline enantioseparation of the analytes was obtained around neutral pH but not in the acidic conditions that are commonly used. HS-beta-CD content, buffer pH, type and concentration, and organic modifier concentration were studied and optimized for fast and efficient separation. A chiral CE separation system composed of 1.5% (w/v) HS-beta-CD, 0 to 10% (v/v) methanol and 20 mM 3-(N-morpholino)propanesulfonic acid at pH 6.5 was shown suitable for baseline enantioseparation of the mentioned amides within 6 min, including simultaneous enantioseparation of three positional isomer series (methyl-, methoxyl or chloro-substituted). By using this system, D-enantiomers migrated ahead of the L-enantiomers and the enantiomeric resolution order of arylglycine amides was more or less parallel to the pK(a), order of the analytes.  相似文献   

14.
A novel positively charged single-isomer of β-cyclodextrin, mono-6-deoxy-6-(3R,4R-dihydroxypyrrolidine)-β-CD chloride (dhypy-CDCl), was synthesized and employed as a chiral selector for the first time in capillary electrophoresis (CE) for the enantioseparation of anionic and ampholytic acids. The effects of the running buffer pH, chiral selector concentration, analyte structure and organic modifier on the enantioseparation were studied in detail. The chiral selectivity and resolution for most of the studied analytes decreased as the buffer pH increased in the range of 6.0–9.0. Increasing selector concentration led to decreased effective mobility, increased chiral selectivity and resolution for most of the studied analytes. Moreover, the hydroxyl groups located on the dihydroxypyrrolidine substituent of the dhypy-CDCl could have influence on the chiral separation.  相似文献   

15.
We investigated the simultaneous chiral separation of nine amphetamine type stimulants (dl-norephedrine, dl-norpseudoephedrine, dl-ephedrine, dl-pseudoephedrine, dl-amphetamine, dl-methamphetamine, dl-methylenedioxyamphetamine (MDA), dl-methylenedioxymethamphetamine (MDMA), and dl-methylenedioxyethylamphetamine (MDEA)) by capillary electrophoresis using highly sulfated gamma-cyclodextrin (SU(XIII)-gamma-CD) as a chiral selector. Three different approaches using SU(XIII)-gamma-CD with 50 mM phosphate background electrolyte were designed; (I) high CD concentration (10 mM SU(XIII)-gamma-CD) at neutral pH (pH 7.0) in the normal polarity mode, (II) low CD concentration (1.0 mM) at low pH (pH 2.6) in the normal polarity mode and (III) high CD concentration at low pH (pH 2.6) in the reversed-polarity mode. In mode (II), the effects of adding three neutral CDs (beta-CD, dimethyl-beta-CD and hydroxypropyl-beta-CD) were also investigated. The best separation was obtained after optimizing mode (III) as follows: run buffer of 10 mM SU(XIII)-gamma-CD with 50 mM phosphate background electrolyte at pH 2.6, applied voltage of -12 kV and capillary temperature of 15 degrees C.  相似文献   

16.
An efficient method for the simultaneous enantioseparation of cyproconazole, bromuconazole, and diniconazole enantiomers was developed by CD‐modified MEKC using a dual mixture of neutral CDs as chiral selector. Three neutral CDs namely hydroxypropyl‐β‐CD, hydroxypropyl‐γ‐CD, and γ‐CD were tested as chiral selectors at different concentrations ranging from 10, 20, 30 and 40 mM, but enantiomers of the studied fungicides were not completely separated. The best dual chiral recognition mode for the simultaneous separation of cyproconazole, bromuconazole, and diniconazole enantiomers was achieved with a mixture of 27 mM hydroxypropyl‐β‐CD and 3 mM hydroxypropyl‐γ‐CD in 25 mM phosphate buffer (pH 3.0) containing 40 mM SDS to which methanol‐acetonitrile (10%:5% v/v) was added as organic modifiers. The best separation was based on the appearance of 10 peaks simultaneously, with good resolution (Rs 1.1–15.9), and peak efficiency (N>200 000). Good repeatabilities in the migration time, peak area, and peak height were obtained in terms of RSD ranging from (0.72 to 1.06)%, (0.39 to 3.49)%, and (1.90 to 4.84)%, respectively.  相似文献   

17.
This work investigates the resolving power of 2,3-dihydroxypropyl-beta-CD (2,3-DHP-beta-CD) and 3-hydroxypropyl-beta-CD (3-HP-beta-CD) as chiral mobile phase additives (CMPAs) using CE. The effects of experimental parameters (CD concentration, buffer pH, and buffer concentration) on enantiorecognition were investigated. More than 20 basic chiral drugs were resolved with satisfactory enantioselectivity. Comparison with 2-hydroxypropyl-beta-CD (2-HP-beta-CD) showed that one or both of the two new chiral selectors show enhanced enantiorecognition for several molecules with bulky substitutes, such as Zopiclone and Mianserin, however, 2-HP-beta-CD has higher enantiorecognition for most of the analytes. Further studies on the structures of analytes and CMPAs showed that the OH moiety on the propyl spacer plays an important role in the separation of some chiral drugs.  相似文献   

18.
Lin CE  Cheng HT  Fang IJ  Liu YC  Kuo CM  Lin WY  Lin CH 《Electrophoresis》2006,27(17):3443-3451
Strategies for simultaneous enantioseparations of three catecholamines (DL-norepinephrine, DL-epinephrine, and DL-isoproterenol) and three structurally related compounds (DL-octopamine, DL-synephrine, and DL-norephedrine) by CZE using sulfated beta-CDs as chiral selectors were investigated. Four different separation modes were attempted: (I) using randomly sulfate-substituted beta-CD (MI-S-beta-CD) at relatively low concentrations in a high-concentration phosphate buffer at low pH in the normal polarity mode, (II) using MI-S-beta-CD at high concentrations at low pH in the reversed polarity mode, (III) using MI-S-beta-CD at moderately high concentrations in a phosphate buffer at neutral pH in the normal polarity mode, and (IV) using the single isomer heptakis(2,3-dihydroxy-6-O-sulfo)-beta-CD (SI-S-beta-CD) at low to moderately high concentrations in a high-concentration BGE at low pH in the normal polarity mode. Among them, enantioseparation of these cationic solutes was best achieved under the conditions of mode (II). In mode (II) and mode (III), temperature is an important factor affecting the enantioresolution of norepinephrine. In mode (I) and mode (IV), the use of a high-concentration BGE (150-200 mM) is crucial for effective enantioseparation of these cationic solutes with sulfated beta-CDs. Comparative studies of enantioseparations of these cationic solutes with MI-S-beta-CD and SI-S-beta-CD reveal that the sulfate substituents of MI-S-beta-CD located at the C(2)- position interact strongly with the diol moiety of catecholamines.  相似文献   

19.
An experimental design approach is described to evaluate the main electrophoretic parameters involved in the enantioseparation of pharmaceuticals by capillary electrophoresis (CE) coupled to electrospray ionization-mass spectrometry (ESI-MS). For all experiments, the partial-filling technique was applied to avoid the chiral selector entering in the mass spectrometer ion source with a negative effect on the electrospray performance. To carry out enantioseparation, a volatile buffer constituted of 20 mM ammonium acetate at pH 4.0, and a polyvinyl alcohol-coated capillary were used. Methadone was employed as the model compound and three different cyclodextrins (CDs), namely sulfobutyl ether-beta-CD, carboxymethylated-beta-CD and hydroxypropyl-beta-CD, were selected in order to study the countercurrent process. Two different experimental designs were chosen: (i) a full-factorial design to examine the effects and significance of the investigated factors, and (ii) a central composite face-centered design to establish the mathematical model of the selected responses in function of experimental factors. The chiral selector concentration, percentage of the capillary filled with the chiral selector, and drying gas nebulization pressure were three relevant factors taken into consideration. For each CD, the methadone enantiomeric resolution, apparent selectivity, and migration time of the second enantiomer were established as responses. The latter were systematically related to experimental parameters with the help of multiple linear regression. It is noteworthy that the behaviour was different in function of the chiral selector charge. Results revealed that the nebulization pressure involved in the electrospray process and the CD concentration had a significant effect on the enantiomeric resolution, while the effect of the separation zone length was less pronounced. Finally, response surfaces were drawn from the mathematical model and experimental conditions were selected to allow a robust determination of methadone enantiomers by CE-MS.  相似文献   

20.
研究了7种新型三唑类抗真菌活性化合物的毛细管电泳法手性分离,利用计算机辅助分子模拟技术研究拆分机理。考察了8种中性环糊精手性添加剂,只有2,6-二甲基-β-环糊精对7种活性化合物都有手性识别能力。在30mmol/L NaH2PO4缓冲液中含2,6-二甲基-β-环糊精30mmol/L,用H3PO4调至pH 2.2,温度20℃,电压20kV,在此条件下7种活性化合物都能达到手性分离,其中4种活性化合物能达到基线分离(Rs>1.5)。应用计算机辅助分子模拟软件Discovery Studio 2.5/Sybyl/Gold模拟2,6-二甲基-β-环糊精与7种活性化合物主客体包结过程,并计算相互结合能,探讨手性识别机理,发现拆分结果与结合能的差异有关,结合能差异越大拆分结果越好。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号