首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Two-dimensional correlation spectroscopy (2DCOS) and near-infrared spectroscopy (NIRS) were used to determine the polyphenol content in oat grain. A partial least squares (PLS) algorithm was used to perform the calibration. A total of 116 representative oat samples from four locations in China were prepared and the corresponding near-infrared spectra were measured. Two-dimensional correlation spectroscopy was employed to select wavelength bands for the PLS regression model for the polyphenol determination. The number of PLS components and intervals was optimized according to the coefficients of determination (R2) and root mean square error of cross validation (RMSECV) in the calibration set. The performance of the final model was evaluated using the correlation coefficient (R) and the root mean square error of validation (RMSEV) in the prediction set. The results showed the band corresponding to the optimal calibration model was between 1350 and 1848?nm and the optimal spectral preprocessing combination was second derivative with second smoothing. The optimal regression model was obtained with an R2 of 0.8954 and an RMSECV of 0.06651 in the calibration set and R of 0.9614 and RMSEV of 0.04573 in the prediction set. These measurements reveal the calibration model had qualified predictive accuracy. The results demonstrated that the 2DCOS with PLS was a simple and rapid method for the quantitative determination of polyphenols in oats.  相似文献   

2.
《Analytical letters》2012,45(15):2388-2399
There is a high demand for rapid determination of fipronil in pesticide preparations because it has been restricted and even prohibited in many countries. An infrared-based methodology was developed for this analyte in acetamiprid formulations by attenuated total reflectance mid-infrared spectroscopy. The quantitative calibration models of fipronil were established by partial least squares regression. The determination coefficients (R2) of the model were above 0.99 while both the root mean square error of prediction and root mean square error of calibration were below 0.0011, which showed the partial least squares model accurately predicted fipronil concentrations in acetamiprid. The accuracy was further demonstrated by comparison with another two models' results of low (<1.0%, w/w) and high concentration sample sets (1.0%–4.5%, w/w). These results demonstrate the potential of infrared spectroscopy to quickly detect fipronil in acetamiprid.  相似文献   

3.
In this paper, a genetic algorithm‐support vector regression (GA‐SVR) coupled approach was proposed for investigating the relationship between fingerprints and properties of herbal medicines. GA was used to select variables so as to improve the predictive ability of the models. Two other widely used approaches, Random Forests (RF) and partial least squares regression (PLSR) combined with GA (namely GA‐RF and GA‐PLSR, respectively), were also employed and compared with the GA‐SVR method. The models were evaluated in terms of the correlation coefficient between the measured and predicted values (Rp), root mean square error of prediction, and root mean square error of leave‐one‐out cross‐validation. The performance has been tested on a simulated system, a chromatographic data set, and a near‐infrared spectroscopic data set. The obtained results indicate that the GA‐SVR model provides a more accurate answer, with higher Rp and lower root mean square error. The proposed method is suitable for the quantitative analysis and quality control of herbal medicines. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
5.
Gentiana rigescens is a famous herbal medicine in China for treatment of convulsion, rheumatism, and jaundice. Here, the infrared determination of gentiopicroside, swertiamarin, sweroside, and loganic acid in G. rigescens from different areas and varieties was presented for the first time. Reference information for the iridoids were obtained by high-performance liquid chromatography. Partial least squares was used to characterize the relationship between spectra matrix and concentration vector for the determination of the analytes. For determination of gentiopicroside, the appropriate performance of partial least squares model was acquired with coefficient of determination of calibration and coefficient of determination of prediction values of 0.965 and 0.868. The root mean square error of estimation (RMSEE), root mean square error of cross validation (RMSECV), root mean square error of prediction (RMSEP), and residual predictive deviation (RPD) values were 2.612, 5.292, 5.239?mg g?1, and 2.701, respectively, based on the first derivative and multiplicative scatter correction. For determination of the total iridoids, the best results were obtained using the coefficient of determination of calibration and coefficient of determination of prediction of 0.943 and 0.834, RMSEE, RMSECV, RMSEP and RPD of 3.896, 7.536, 6.543?mg g?1 and 2.438, respectively, based on the first derivative. Both models were reliable and robust. The results demonstrated that infrared spectroscopy provided a rapid, low-cost tool to monitor the quality of G. rigescens by the determination of the iridoids.  相似文献   

6.
7.
The potential of near-infrared spectroscopy (NIRS) for the quality control of traditional Chinese medicine has been evaluated. Seven quantitative parameters, andrographolide, deoxyandrographolide, dehydroandrographolide, neoandrographolide, moisture, ash content, and alcohol-soluble extract of Andrographis paniculata, were evaluated by NIRS. The reference values of andrographolides were determined by high-performance liquid chromatography, and the others were obtained using the standard methods of the 2015 Chinese Pharmacopoeia. The predicted values were determined by a quantitative model using NIRS based on partial least square regression. Different spectral preprocessing methods, spectral ranges, and optimum number of factors were selected to optimize the models. All models were estimated by the combination of various parameters, including the correlation coefficient of calibration for andrographolide, deoxyandrographolide, dehydroandrographolide, neoandrographolide, moisture, ash content, alcohol-soluble extract (values of 0.980, 0.984, 0.989, 0.983, 0.987, 0.988, 0.979, respectively), root mean square error of calibration (values of 0.156, 0.038, 0.050, 0.029, 0.604, 0.431, 0.135, respectively), root mean square error of prediction (values of 0.169, 0.041, 0.050, 0.033, 0.280, 0.493, 0.140, respectively), root mean square error of cross-validation (values of 0.626, 0.114, 0.158, 0.046, 1.145, 0.774, 0.508, respectively), and ratio of standard deviation to standard error of prediction (values of 4.583, 4.690, 4.796, 4.899, 4.899, 4.690, 5.099, respectively). The results show that the calibration models by NIRS are reliable and can be applied for the quantification for seven parameters from A. paniculata for quality control in traditional Chinese medicine production and processing.  相似文献   

8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
This paper proposes an analytical method for simultaneous near-infrared (NIR) spectrometric determination of α-linolenic and linoleic acid in eight types of edible vegetable oils and their blending. For this purpose, a combination of spectral wavelength selection by wavelet transform (WT) and elimination of uninformative variables (UVE) was proposed to obtain simple partial least square (PLS) models based on a small subset of wavelengths. WT was firstly utilized to compress full NIR spectra which contain 1413 redundant variables, and 42 wavelet approximate coefficients were obtained. UVE was then carried out to further select the informative variables. Finally, 27 and 19 wavelet approximate coefficients were selected by UVE for α-linolenic and linoleic acid, respectively. The selected variables were used as inputs of PLS model. Due to original spectra were compressed, and irrelevant variables were eliminated, more parsimonious and efficient model based on WT-UVE was obtained compared with the conventional PLS model with full spectra data. The coefficient of determination (r2) and root mean square error prediction set (RMSEP) for prediction set were 0.9345 and 0.0123 for α-linolenic acid prediction by WT-UVE-PLS model. The r2 and RMSEP were 0.9054, 0.0437 for linoleic acid prediction. The good performance showed a potential application using WT-UVE to select NIR effective variables. WT-UVE can both speed up the calculation and improve the predicted results. The results indicated that it was feasible to fast determine α-linolenic acid and linoleic acid content in edible oils using NIR spectroscopy.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号