摘    要:We present the design and experimental results for a diode pumped Nd:YLF regenerative amplifier applied to amplify a nanosecond laser pulse. Numerical simulation shows that the maximum output energy and the best stability can be obtained when the regenerative amplifier operates in a saturated mode for all pulse duration and temporal profiles. Using extra post-pulse is a good method to decrease the square-pulse distortion caused by gain saturation effect. The amplifier shows output energy of 4.2mJ with a total energy gain of more than 10^7 and output energy stability of better than 1% rms. When extra post-pulse is added, square-pulse distortion is decreased from 1.33 to 1.17 for the amplifier that is seeded with an optical pulse of 3ns.

关 键 词:Nd:YLF正反馈放大器  稳定性  二极管  光泵
收稿时间:2007-11-29

Highly Stable, Diode-Pumped Nd:YLF Regenerative Amplifier
WANG Jiang-Feng,LI Xue-Chun,WEI Hui,ZHU Jian-Qiang.Highly Stable, Diode-Pumped Nd:YLF Regenerative Amplifier[J].Chinese Physics Letters,2008,25(2):524-527.
Authors:WANG Jiang-Feng  LI Xue-Chun  WEI Hui  ZHU Jian-Qiang
Affiliation:Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800
Abstract:We present the design and experimental results for a diode pumped Nd:YLF regenerative amplifier applied to amplify a nanosecond laser pulse. Numerical simulation shows that the maximum output energy and the best stability can be obtained when the regenerative amplifier operates in a saturated mode for all pulse duration and temporal profiles. Using extra post-pulse is a good method to decrease the square-pulse distortion caused by gain saturation effect. The amplifier shows output energy of 4.2mJ with a total energy gain of more than 107 and output energy stability of better than 1% rms. When extra post-pulse is added, square-pulse distortion is decreased from 1.33 to 1.17 for the amplifier that is seeded with an optical pulse of 3ns.