Novel correction method for X-ray beam energy fluctuation of high energy DR system with a linear detector
作者姓名:杨民  陈浩  孟凡勇  魏东波
作者单位:1. School of Mechanical Engineering and Automation, Beijing Univ. of Aeronautics and Astronautics, Beijing 100191, China;;2. Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China;;3. State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China
基金项目:Supported by National Natural Science Foundation of China (60872080, 61077011); National State Key Laboratory of Multiphase Complex Systems (MPCS-2011-D-03); Beijing Municipal Commission of Education (BMCE) under the Joint-Building Project
摘    要:A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufacturing technology for accelerators, an energy fluctuation of the X-ray beam exists and leads to bright and dark streak artifacts in the DR image. Here we report the utilization of a new software-based method to correct the fluctuation artifacts. The correction method is performed using a high pass filtering operation to extract the high frequency information that reflects the X-ray beam energy fluctuation, and then subtracting it from the original image. Our experimental results show that this method is able to rule out the artifacts effectively and is readily implemented on a practical scanning system.

关 键 词:X射线束  DR系统  高能量  波动  校正方法  探测器  线性  工业无损检测
收稿时间:2011-1-27
修稿时间:2011-3-21

Novel correction method for X-ray beam energy fluctuation of high energy DR system with a linear detector
YANG Min , CHEN Hao MENG Fan-Yong WEI Dong-Bo School of Mechanical Engineering , Automation,Beijing Univ. of Aeronautics , Astronautics,Beijing ,China Institute of Applied Electronics,China Academy of Engineering Physics,Mianyang ,China State Key Laboratory of Multiphase Complex Systems.Novel correction method for X-ray beam energy fluctuation of high energy DR system with a linear detector[J].High Energy Physics and Nuclear Physics,2011,35(11):1074-1078.
Authors:YANG Min  CHEN Hao MENG Fan-Yong WEI Dong-Bo School of Mechanical Engineering  Automation  Beijing Univ of Aeronautics  Astronautics  Beijing  China Institute of Applied Electronics  China Academy of Engineering Physics  Mianyang  China State Key Laboratory of Multiphase Complex Systems
Affiliation:YANG Min 1,1) CHEN Hao 2 MENG Fan-Yong 3 WEI Dong-Bo1 1 School of Mechanical Engineering and Automation,Beijing Univ. of Aeronautics and Astronautics,Beijing 100191,China 2 Institute of Applied Electronics,China Academy of Engineering Physics,Mianyang 621900,China 3 State Key Laboratory of Multiphase Complex Systems,Institute of Process Engineering,Chinese Academy of Sciences,Beijing 100190,China
Abstract:A high energy digital radiography (DR) testing system has generated diverse scientific and technological interest in the field of industrial non-destructive testing. However, due to the limitations of manufac-turing technology for accelerators, an energy fluctuation of the X-ray beam exists and leads to bright and dark streak artifacts in the DR image. Here we report the utilization of a new software-based method to correct the fluctuation artifacts. The correction method is performed using a high pass filt...
Keywords:X-ray testing  accelerator  X–ray beam energy fluctuation  high pass filter  artifacts