首页 | 官方网站   微博 | 高级检索  
     

大型透明件透光率和雾度测量装置的研制
引用本文:吴富,任建伟,李葆勇,万志,刘洪兴,刘则洵.大型透明件透光率和雾度测量装置的研制[J].应用光学,2014,35(5):789-793.
作者姓名:吴富  任建伟  李葆勇  万志  刘洪兴  刘则洵
作者单位:1.中国科学院长春光学精密机械与物理研究所,吉林 长春 130033;
基金项目:国家“863计划”高技术研究发展计划资助(86325113B)
摘    要:为现场测量大型透明件的透光率和雾度,提出了基于双积分球结构的测量和系统参数标定方案,并设计研制了相应的透光率和雾度测量装置。该装置通过六维机械调整装置完成光路调整,基于LED光源的照明准直系统产生调制平行光,最后采用双积分球结构的探测接收装置并结合锁相放大技术,实现光电信号的解调。测试结果表明,该装置对透光率测量的绝对误差不超过1%,对雾度测量的绝对误差不超过0.3%,符合工程应用对系统测量精度提出的要求。另一方面,装置具有很好的重复性,其对透光率和雾度测量的相对标准差分别为0.06 %和0.05%。

关 键 词:测量    透光率    雾度    双积分球
收稿时间:2014/5/23

Meter for luminous transmittance and haze of large transparent component
Affiliation:1.Changchun Institute of Optics,Fine Mechanics and Physics,CAS,Changchun 130033,China;2.University of Chinese Academy of Sciences,Beijing 100049,China
Abstract:In order to obtain the luminous transmittance and haze of large transparent component in field, measurement scheme and method of calibration of system parameters based on double integrating spheres structure were presented. Furthermore the testing device was designed and manufactured. The optical path of device was adjusted by 6 dimensional mechanical adjustment structure firstly. Then the modulated directional light was generated by the illumination and collimation system based on LED source. Finally by using the detective part of double integrating spheres structure and the phase-locked amplifier technology, the signal was demodulated accordingly. The testing result shows that, by using the device, the absolute error of light transmittance is no more than 1% and that of haze is no more than 0.3%, which meet the precision requirement of engineering application. Moreover the repeatability of device was also good. The relative standard deviation of luminous transmittance and haze was 0.06 % and 0.05% respectively.
Keywords:measurement  light transmittance  haze  double integrating spheres
点击此处可从《应用光学》浏览原始摘要信息
点击此处可从《应用光学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号