首页 | 官方网站   微博 | 高级检索  
     

Measurements of AIM for Visible Wavelength Based on Individual Eye Model
作者姓名:王伟  王肇圻  王雁  左彤  赵堪兴
作者单位:[1]Institute of Modern Optics, Nankai University, Tianjin 300071 [2]Refractive Surgery Center, Tianjin Eye Hospital, Tianfin 300020
基金项目:Supported by the Key Project of the National Natural Science Foundation of China under Grant No 60438030, the Key Research Foundation of Scientific and Technical Committee of Tianjin City of China under Grant No 033183711, and the Specialized Research Fund for the Doctoral Programme of Higher Education of China under Grant No 20050055002.
摘    要:We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.

关 键 词:个体人眼模型  可见光  波长  AIM
收稿时间:2006-05-19
修稿时间:2006-05-19

Measurements of AIM for Visible Wavelength Based on Individual Eye Model
WANG Wei,WANG Zhao-Qi,WANG Yan,ZUO Tong,ZHAO Kan-Xing.Measurements of AIM for Visible Wavelength Based on Individual Eye Model[J].Chinese Physics Letters,2006,23(12):3263-3266.
Authors:WANG Wei  WANG Zhao-Qi  WANG Yan  ZUO Tong  ZHAO Kan-Xing
Affiliation:1.Institute of Modern Optics, Nankai University, Tianjin 300071 ;2.Refractive Surgery Center, Tianjin Eye Hospital, Tianjin 300020
Abstract:We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.
Keywords:42  30  Va  42  66  Ew
本文献已被 维普 等数据库收录!
点击此处可从《中国物理快报》浏览原始摘要信息
点击此处可从《中国物理快报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23