首页 | 官方网站   微博 | 高级检索  
     


Robust scatter correction method for cone-beam CT using an interlacing-slit plate
Authors:Kui-Dong Huang  Zhe Xu  Ding-Hua Zhang  Hua Zhang  Wen-Long Shi
Affiliation:1.  Key Lab of Contemporary Design and Integrated Manufacturing Technology of the Ministry of Education, Northwestern Polytechnical University, Xi'an 710072, China2.  School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
Abstract:Cone-beam computed tomography(CBCT) has been widely used in medical imaging and industrial nondestructive testing,but the presence of scattered radiation will cause significant reduction of image quality.In this article,a robust scatter correction method for CBCT using an interlacing-slit plate(ISP) is carried out for convenient practice.Firstly,a Gaussian filtering method is proposed to compensate the missing data of the inner scatter image,and simultaneously avoid too-large values of calculated inner scatter and smooth the inner scatter field.Secondly,an interlacing-slit scan without detector gain correction is carried out to enhance the practicality and convenience of the scatter correction method.Finally,a denoising step for scatter-corrected projection images is added in the process flow to control the noise amplification The experimental results show that the improved method can not only make the scatter correction more robust and convenient,but also achieve a good quality of scatter-corrected slice images.
Keywords:CBCT  scatter correction  image fusion  interlacing-slit  noise control
本文献已被 CNKI 等数据库收录!
点击此处可从《中国物理C(英文版)》浏览原始摘要信息
点击此处可从《中国物理C(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23