首页 | 本学科首页   官方微博 | 高级检索  
     

惯性约束聚变软X射线在线标定系统概念设计
引用本文:曹磊峰, 杨祖华, 陈纪辉, 等. 惯性约束聚变软X射线在线标定系统概念设计[J]. 强激光与粒子束, 2020, 32: 112007. doi: 10.11884/HPLPB202032.200141
作者姓名:曹磊峰  杨祖华  陈纪辉  魏来  范全平  陈勇  张强强  周维民
作者单位:中国工程物理研究院 激光聚变研究中心 等离子体物理重点实验室,四川 绵阳 621900
基金项目:国家重大科技专项项目;国家自然科学基金项目(11375160);国家重大科学仪器设备开发专项项目(2012YQ130125)
摘    要:
长期以来,惯性约束聚变(ICF)研究软X射线诊断科学仪器设备的元器件标定工作主要依赖同步辐射光源X射线辐射计量站进行。该类装置通常与用于开展ICF研究的大型激光装置分处两地,难以满足ICF研究软X射线元器件实时实地的标定应用需求。另外,由于同步辐射和ICF激光等离子体产生的X射线辐射特性存在较大差异,同步辐射计量站的标定结果事实上也不能完全反映元器件在ICF实验应用中的计量响应特性。本文首先介绍一种基于单光学元件的软X射线紧凑型无谐波光源单色化技术,以此为基础提出研制基于ICF激光等离子体X射线源的同源、同几何位形、双束比较校准的多能量通道光源单色化系统,用于ICF应用软X射线元器件的在线标定。新系统一方面可望满足ICF软X射线元器件实时实地的标定应用需求;另一方面,其提供的标定光束的技术特征将最大可能地接近ICF激光等离子体X射线辐射本身。配备相应的X射线二极管(XRD)和标准探测器之后,该系统将形成一套具有在线自校准功能的新型多通道δ能量响应软X射线能谱仪。

关 键 词:惯性约束聚变   软X射线   标定   激光等离子体   等离子体诊断
收稿时间:2020-05-24
修稿时间:2020-07-04

Conceptual design of soft X-ray online calibration system for ICF
Cao Leifeng, Yang Zuhua, Chen Jihui, et al. Conceptual design of soft X-ray online calibration system for ICF[J]. High Power Laser and Particle Beams, 2020, 32: 112007. doi: 10.11884/HPLPB202032.200141
Authors:Cao Leifeng  Yang Zuhua  Chen Jihui  Wei Lai  Fan Quanping  Chen Yong  Zhang Qiangqiang  Zhou Weimin
Affiliation:Science & Technology on Plasma Physics Laboratory, Research Center of Laser Fusion, CAEP, Mianyang 621900, China
Abstract:
For a long time, the calibration of soft X-ray diagnostic equipment components of ICF research mainly depends on the synchrotron radiation source X-ray metrology station. This kind of device is usually located in a different place from the large laser facility for ICF research, thus it is difficult to meet the real-time field calibration application requirements of ICF’s research soft X-ray components research. In addition, in view of the great difference between the radiation characteristics of synchrotron radiation X-ray and ICF laser plasma X-ray, the calibration results of synchrotron radiation measurement station can not completely measure the response characteristics of components in ICF experiments. In this paper, a kind of monochromatic technology for compact non-harmonic soft X-ray source is introduced. Based on this technology, a monochromatic system of multi energy channel source based on ICF laser plasma X-ray source with homologous, geometric configuration and double beam comparison calibration is developed for on-line calibration of soft X-ray components in ICF applications. The new system is expected to meet the requirements of real-time calibration application of ICF’s soft X-ray components, while the technical characteristics of its calibration beam will be as close as possible to that of the ICF laser plasma X-ray radiation.
Keywords:inertial confinement fusion  soft X-ray  calibration  laser plasma  plasma diagnosis
本文献已被 万方数据 等数据库收录!
点击此处可从《强激光与粒子束》浏览原始摘要信息
点击此处可从《强激光与粒子束》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号